文献速递妇产影像儿科影像技术与安全US

供血儿大脑中动脉收缩期峰值流速升高与双胎输血综合征中供血儿死亡风险相关而与双胎贫血-红细胞增多序列征无关

Elevated middle cerebral artery peak systolic velocity and risk of death in donor twin affected by twin-twin transfusion syndrome but not twin anemia-polycythemia sequence.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-06-22

这项前瞻性单中心队列研究纳入2011至2022年间接受激光手术的507例双胎输血综合征(TTTS)病例,排除双胎贫血-红细胞增多序列征(TAPS)。在校正选择性胎儿生长受限(sFGR)、TTTS分期等混杂因素后,供血儿大脑中动脉收缩期峰值流速(MCA-PSV)升高(>1.5倍中位数)是供血儿胎死宫内的独立危险因素(aRR 4.52,95%CI 2.72-7.50)。供血儿MCA-PSV(以中位数倍数计)与供血儿胎死宫内在ROC曲线下面积为0.69(P<0.001),而受血儿MCA-PSV与受血儿胎死宫內无关(AUC 0.54,P=0.44)。

要点

  • 供血儿MCA-PSV>1.5 MoM是供血儿胎死宫内的独立危险因素,校正后aRR为4.52(95%CI 2.72-7.50)。
  • 供血儿MCA-PSV(MoM)预测供血儿胎死宫内的AUC为0.69(P<0.001),受血儿MCA-PSV与受血儿胎死宫內无关(AUC 0.54,P=0.44)。
  • 高MCA-PSV组供血儿中低MCA-PI比例高于正常MCA-PSV组(33.3% vs 15.5%,P=0.016)。

核心结论

  • 在无TAPS的TTTS中,激光手术前供血儿MCA-PSV升高与供血儿胎死宫内风险增加约4倍相关(校正sFGR、TTTS分期等混杂因素后);激光手术前多普勒评估供血儿MCA-PSV可能有助于细化TTTS分期以评估供血儿胎死宫内风险。

研究设计与样本

  • 前瞻性队列研究,单中心,2011至2022年接受激光手术的TTTS病例,排除TAPS后纳入507例;采用多变量和Poisson回归分析,校正TTTS分期、选择性胎儿生长受限(sFGR)及其他混杂因素。

诊断标准与关键数值

  • 供血儿MCA-PSV升高定义为>1.5倍中位数(MoM);高供血儿MCA-PSV见于6.5%(33/507)病例;供血儿MCA-PSV(MoM)预测供血儿胎死宫内的AUC为0.69(P<0.001);受血儿MCA-PSV(MoM)预测受血儿胎死宫内的AUC为0.54(P=0.44)。

临床应用与阅片要点

  • 激光手术前多普勒评估供血儿MCA-PSV可能有助于细化TTTS分期以评估供血儿胎死宫内风险;高供血儿MCA-PSV组中低MCA-PI比例高于正常供血儿MCA-PSV组(33.3% vs 15.5%,P=0.016)。

局限性

  • 660例TTTS中48例(7.3%)未记录供血儿MCA-PSV。
  • 剩余612例中9例(1.5%)失访。
  • 96例TAPS被排除。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the association between elevated (> 1.5 multiples of the median (MoM)) middle cerebral artery (MCA) peak systolic velocity (PSV) and fetal demise of the donor twin in pregnancies complicated by twin-twin transfusion syndrome (TTTS) in the absence of twin anemia-polycythemia sequence (TAPS). Secondary objectives were to evaluate if donor or recipient MCA-PSV is associated with a risk for their corresponding fetal death, and to compare the proportion of donor fetuses with low MCA pulsatility index (PI) among donor twins with high MCA-PSV and those with normal MCA-PSV to evaluate the contribution of blood-flow redistribution to the fetal brain in donor twins with high MCA-PSV.

METHODS: This prospective cohort study included TTTS cases that underwent laser surgery between 2011 and 2022 at a single center. TAPS cases were excluded from the study. Multivariable and Poisson regression analysis were performed to explore the association between isolated elevated donor MCA-PSV and fetal demise, adjusted for TTTS stage, selective fetal growth restriction (sFGR) and other confounders.

RESULTS: Of 660 TTTS cases, donor MCA-PSV was not recorded in 48 (7.3%) cases. Of the remaining 612 patients, nine (1.5%) were lost to follow-up and 96 TAPS cases were excluded; thus, 507 cases were included in the study. High donor MCA-PSV was seen in 6.5% (33/507) of cases and was an independent risk factor for donor fetal demise (adjusted relative risk (aRR), 4.52 (95% CI, 2.72-7.50)), after adjusting for confounders. Regression analysis restricted to each Quintero TTTS stage demonstrated that high donor MCA-PSV was an independent risk factor for fetal demise of the donor in Quintero Stage II (aRR, 14.21 (95% CI, 1.09-186.2)) and Quintero Stage III (aRR, 3.41 (95% CI, 1.82-6.41)). Donor MCA-PSV in MoM was associated with fetal demise of the donor (area under the receiver-operating-characteristics curve (AUC), 0.69; P < 0.001), but recipient MCA-PSV in MoM was not associated with fetal demise of the recipient (AUC, 0.54; P = 0.44). A higher proportion of donor twins in the group with high MCA-PSV had a low MCA-PI compared to the group with normal MCA-PSV (33.3% vs 15.5%; P = 0.016).

CONCLUSIONS: Elevated donor MCA-PSV without TAPS prior to laser surgery for TTTS is associated with a 4-fold increased risk for donor fetal demise, adjusted for sFGR, TTTS stage and other confounders. Doppler evaluation of donor MCA-PSV prior to laser surgery may help stratify TTTS staging to evaluate the risk of donor fetal demise. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Espinoza J, Agarwal N, Johnson A, et al. Elevated middle cerebral artery peak systolic velocity and risk of death in donor twin affected by twin-twin transfusion syndrome but not twin anemia-polycythemia sequence. Ultrasound Obstet Gynecol. 2024. PMID: 38437460. doi:10.1002/uog.27629

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。