大鼠脑穹窿MR引导聚焦超声(MRgFUS)损毁方法的建立

Development of an MR-Guided Focused Ultrasound (MRgFUS) Lesioning Approach for the Fornix in the Rat Brain.
PubMed 文献 · Ultrasound Med Biol · 2024-03-22

研究在大鼠脑建立MR引导聚焦超声损毁穹窿的方法,比较去骨瓣与颅骨变薄两种颅骨准备,并比较两种探头定位系统;去骨瓣可减少颅骨与近场加热,加装微操纵器后穹窿靶向精度提高133%。

要点

  • 去骨瓣颅骨准备是减少颅骨与近场加热的必要条件。
  • 高频(3MHz)小焦域探头联合MR声辐射力成像可确认焦斑位置。
  • 加装微操纵器(约0.1mm精度)使穹窿靶向精度较仅电动调节系统提高133%。

核心结论

  • 所描述方法可对大鼠脑内小且深的结构(如穹窿)进行可重复且准确的靶向损毁,从而支持在慢性疾病模型中研究神经系统疾病。

研究设计与样本

  • 研究分两部分:第一部分比较颅骨变薄(n=7个损毁灶)与去骨瓣(n=22个损毁灶)两种颅骨准备;第二部分以穹窿为皮层下损毁靶点,比较两种探头定位系统,并用组织学方法评估高频小焦域探头联合MR声辐射力成像的靶向准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: High-intensity magnetic resonance-guided focused ultrasound (MRgFUS) is a non-invasive therapy to lesion brain tissue, used clinically in patients and pre-clinically in several animal models. Challenges with focused ablation in rodent brains can include skull and near-field heating and accurately targeting small and deep brain structures. We overcame these challenges by creating a novel method consisting of a craniectomy skull preparation, a high-frequency transducer (3 MHz) with a small ultrasound focal spot, a transducer positioning system with an added manual adjustment of ∼0.1 mm targeting accuracy, and MR acoustic radiation force imaging for confirmation of focal spot placement.

METHODS: The study consisted of two main parts. First, two skull preparation approaches were compared. A skull thinning approach (n = 7 lesions) was compared to a craniectomy approach (n = 22 lesions), which confirmed a craniectomy was necessary to decrease skull and near-field heating. Second, the two transducer positioning systems were compared with the fornix chosen as a subcortical ablation target. We evaluated the accuracy of targeting using histologic methods from a high-frequency transducer with a small ultrasound focal spot and MR acoustic radiation force imaging.

RESULTS: Comparing a motorized adjustment system (∼1 mm precision, n = 17 lesions) to the motorized system with an added micromanipulator (∼0.1 mm precision, n = 14 lesions), we saw an increase in the accuracy of targeting the fornix by 133%.

CONCLUSIONS: The described work allows for repeatable and accurate targeting of small and deep structures in the rodent brain, such as the fornix, enabling the investigation of neurological disorders in chronic disease models.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。