指南与共识神经CTMR

急性卒中一致性比较:自动ASPECT评分软件工具与手动共识评分

Comparison of consistency in acute stroke: Automated ASPECT score software tools and manual consensus scores.
指南 / 共识 · Eur J Radiol · 2024-03-20

回顾性纳入2019年2月至2022年6月174例急性缺血性卒中患者,以两名放射科医师基于DWI讨论后的一致评分作为参考标准,比较Rapid、RealNow、ShuKun三种自动ASPECTS软件与手动共识评分的一致性。三种软件与参考标准的ICC分别为0.51、0.60、0.52,AUC分别为0.61、0.67、0.62;非优势半球与优势半球的评分相关性存在统计学差异(P < 0.05)。

要点

  • RealNow-ASPECTS与参考标准的一致性不劣于Rapid和ShuKun,甚至更好(ICC 0.60 vs 0.51、0.52)。
  • 三种软件总分与参考标准的相关性为中等(ICC 0.51–0.60),AUC 0.61–0.67。
  • 非优势半球与优势半球区域评分的相关性存在统计学差异(P < 0.05)。

核心结论

  • 三种自动评分软件与参考标准的总体评分一致性相当,RealNow-ASPECTS的一致性不劣于Rapid-ASPECTS和ShuKun-ASPECTS,甚至优于两者;但一致性等级仍有提升空间。

研究设计与样本

  • 回顾性研究,纳入2019年2月至2022年6月出现卒中症状的患者174例;两名放射科医师独立阅NCCT,4周后随机阅DWI并讨论分歧,以一致结果作为参考标准。

诊断标准与关键数值

  • 专家共识读片的中位ASPECTS为7(5–9);三种软件工具间ASPECTS总分的相关性为0.70、0.74、0.83;参考标准与Rapid-ASPECTS的ICC=0.51、Cronbach's α=0.53,与RealNow-ASPECTS的ICC=0.60、Cronbach's α=0.70,与ShuKun-ASPECTS的ICC=0.52、Cronbach's α=0.64;Rapid、RealNow、ShuKun的AUC分别为0.61、0.67、0.62。

临床应用与阅片要点

  • 作者认为RealNow-ASPECTS的一致性不劣于Rapid-ASPECTS和ShuKun-ASPECTS,甚至更好;区域特异性评分相关性为差至好,非优势半球与优势半球和参考标准的相关性存在统计学差异(P < 0.05)。

局限性

  • 原文自述三种软件与参考标准的一致性等级仍有待发展(the consistency grade that still is developable)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The Alberta Stroke Program Early Computed Tomography Score (ASPECTS) is a standardized semi-quantitative scoring system. It is widely used to assess the extent of acute ischemic stroke (AIS). We evaluated the consistency of three automatic software packages with the overall and region-specific manual ASPECTS scores of AIS patients.

METHODS: Retrospectively, we gathered patients who presented with stroke symptoms between February 2019 and June 2022, and 174 cases were eventually included in the trial. Two radiologists reviewed the NCCT images independently; After four weeks, the same two radiologists began randomly reviewing the DWI images, discussed different scores and give consistent results as ground truth.

RESULTS: Median ASPECTS of the expert consensus reading was 7 (5-9). Good to excellent correlation of ASPECTS total scores among the three software tools (0.70, 0.74 and 0.83). Correlation among ground truth and Rapid-ASPECTS, RealNow-ASPECTS, ShuKun-ASPECTS (ICC = 0.51, Cronbach's α = 0.53), (ICC = 0.60, Cronbach's α = 0.70) and (ICC = 0.52, Cronbach's α = 0.64) respectively. The AUCs for Rapid, RealNow and ShuKun were 0.61, 0.67, and 0.62 respectively. The region-specific results showed a poor to good correlation. The correlations between the non-dominant and dominant cerebral hemispheres and the ground truth were statistically different (P < 0.05).

CONCLUSIONS: Overall, the scoring consistency between the three automated scoring software and the ground truth is comparable, with RealNow-ASPECTS being no less consistent and effective than Rapid-ASPECTS and ShuKun-ASPECTS, and even better than both. But the consistency grade that still is developable.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Liu D, Yuan J, Ren R, et al. Comparison of consistency in acute stroke: Automated ASPECT score software tools and manual consensus scores. Eur J Radiol. 2024. PMID: 38537606. doi:10.1016/j.ejrad.2024.111435

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。