文献速递神经MR

压缩敏感度编码人工智能通过优化图像质量并缩短扫描时间加速脑转移瘤成像

Compressed Sensitivity Encoding Artificial Intelligence Accelerates Brain Metastasis Imaging by Optimizing Image Quality and Reducing Scan Time.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-04-08

纳入51例疑似脑转移瘤的癌症患者,比较压缩敏感度编码人工智能(CS-AI)与标准压缩SENSE(CS6)在CE 3D-T1WI和CE 3D-FLAIR序列上的图像质量与扫描时间。CS-AI组CNR和SNR均优于CS6,图像质量评分在加速因子达10时仍良好,CS-AI10扫描时间分别缩短39.25%和39.93%。作者认为CS-AI10适合临床应用,可提供最佳图像质量并缩短扫描时间。

要点

  • CS-AI重建在相同加速因子下CNR和图像质量评分均优于CS协议。
  • CS-AI10在CE 3D-T1WI和CE 3D-FLAIR上图像质量最优,扫描时间分别缩短39.25%和39.93%。
  • CS-AI10改善灰白质边界和病灶区域的勾画。

核心结论

  • CE 3D-T1WI和CE 3D-FLAIR序列采用CS-AI重建检测脑转移瘤,可能提供比CS更有效的替代重建方法;CS-AI10适合临床应用,提供最佳图像质量并缩短扫描时间。

研究设计与样本

  • 纳入51例疑似脑转移瘤的癌症患者,其中50例接受不同的定制CE 3D-T1WI或CE 3D-FLAIR序列扫描,以压缩SENSE加速6(CS6)商用标准序列为参考标准,采用定量和定性方法评估图像质量,2名神经放射学家独立进行定性评估。

关键影像表现/征象

  • CS-AI10扫描改善正常灰白质边界和病灶区域的勾画(P < .05)。
  • CS-AI组定性图像质量评分在加速因子高达10时仍良好(all P < .05)。

诊断标准与关键数值

  • 在相同加速因子下,CS-AI协议CE 3D-T1WI和CE 3D-FLAIR的CNR优于CS协议(P < .05)。
  • 与参考CS6相比,CS-AI组CNR值更高(all P < .05),其中CS-AI10扫描CNR值最高。
  • CS-AI组CE 3D-T1WI和CE 3D-FLAIR的SNR均优于参考CS6(all P < .05)。
  • 在相同加速因子下,CS-AI协议图像质量评分高于CS协议(all P < .05)。
  • 与参考CS6相比,CS-AI10的CE 3D-T1WI和CE 3D-FLAIR扫描时间分别缩短39.25%和39.93%。

临床应用与阅片要点

  • 作者认为CS-AI10适合临床应用,可提供最佳图像质量并缩短扫描时间。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Accelerating the image acquisition speed of MR imaging without compromising the image quality is challenging. This study aimed to evaluate the feasibility of contrast-enhanced (CE) 3D T1WI and CE 3D-FLAIR sequences reconstructed with compressed sensitivity encoding artificial intelligence (CS-AI) for detecting brain metastases (BM) and explore the optimal acceleration factor (AF) for clinical BM imaging.

MATERIALS AND METHODS: Fifty-one patients with cancer with suspected BM were included. Fifty participants underwent different customized CE 3D-T1WI or CE 3D-FLAIR sequence scans. Compressed SENSE encoding acceleration 6 (CS6), a commercially available standard sequence, was used as the reference standard. Quantitative and qualitative methods were used to evaluate image quality. The SNR and contrast-to-noise ratio (CNR) were calculated, and qualitative evaluations were independently conducted by 2 neuroradiologists. After exploring the optimal AF, sample images were obtained from 1 patient by using both optimized sequences.

RESULTS: Quantitatively, the CNR of the CS-AI protocol for CE 3D-T1WI and CE 3D-FLAIR sequences was superior to that of the CS protocol under the same AF (P < .05). Compared with reference CS6, the CS-AI groups had higher CNR values (all P < .05), with the CS-AI10 scan having the highest value. The SNR of the CS-AI group was better than that of the reference for both CE 3D-T1WI and CE 3D-FLAIR sequences (all P < .05). Qualitatively, the CS-AI protocol produced higher image quality scores than did the CS protocol with the same AF (all P < .05). In contrast to the reference CS6, the CS-AI group showed good image quality scores until an AF of up to 10 (all P < .05). The CS-AI10 scan provided the optimal images, improving the delineation of normal gray-white matter boundaries and lesion areas (P < .05). Compared with the reference, CS-AI10 showed reductions in scan time of 39.25% and 39.93% for CE 3D-T1WI and CE 3D-FLAIR sequences, respectively.

CONCLUSIONS: CE 3D-T1WI and CE 3D-FLAIR sequences reconstructed with CS-AI for the detection of BM may provide a more effective alternative reconstruction approach than CS. CS-AI10 is suitable for clinical applications, providing optimal image quality and a shortened scan time.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Wang M, Ma Y, Li L, et al. Compressed Sensitivity Encoding Artificial Intelligence Accelerates Brain Metastasis Imaging by Optimizing Image Quality and Reducing Scan Time. AJNR Am J Neuroradiol. 2024. PMID: 38485196. doi:10.3174/ajnr.A8161

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。