文献速递技术与安全神经US

确定用于脊髓损伤的聚合物微泡爆破超声参数

Determining Ultrasound Parameters for Bursting Polymer Microbubbles for Future Use in Spinal Cord Injury.
PubMed 文献 · Ultrasound Med Biol · 2024-03-22

研究在大鼠尸体脊髓损伤模型中用临床超声爆破聚乳酸微泡,体外确定1、2.25和5 MHz频率下爆破阈值在峰值负压0.2至0.5 MPa之间,阈值随频率降低而下降,2.25 MHz接近共振频率2.5至3.0 MHz时爆破优化,载寡核苷酸微泡爆破后释放显著增多。

要点

  • 临床超声在大鼠尸体脊髓损伤模型中可实现原位成像与微泡爆破。
  • 体外爆破阈值在峰值负压0.2至0.5 MPa之间,且随频率降低而下降。
  • 聚乳酸微泡爆破后塌陷至0.5至1 µm而不碎裂,载药微泡爆破后寡核苷酸释放显著增多。

核心结论

  • 用碳酸铵制备的聚乳酸微泡在合适参数下爆破,有潜力通过靶向超声安全改善脊髓损伤的鞘内治疗递送。

研究设计与样本

  • 研究论文;在大鼠尸体脊髓损伤模型中使用临床超声测试微泡,体外比较碳酸铵与氨基甲酸铵两种致孔剂并评估共振频率、声学增强、粒径与形态,参考标准为超声暴露后增强变化确定的爆破压力阈值。

关键影像表现/征象

  • 聚乳酸微泡初始平均尺寸约2 µm,爆破后保持完整、塌陷至0.5至1 µm且未碎裂。
  • 使用氨基甲酸铵时检测到微泡大小的碎片,导致微泡浓度测量不准确。

诊断标准与关键数值

  • 体外爆破阈值在频率1、2.25和5 MHz下确定于峰值负压0.2至0.5 MPa之间,据认为对脊髓安全。
  • 爆破阈值随频率降低而下降。
  • 聚乳酸微泡爆破在共振频率2.5至3.0 MHz附近使用2.25 MHz时优化,而非在更低频率下优化。
  • 载寡核苷酸微泡经超声爆破后释放的寡核苷酸显著多于未爆破时。

临床应用与阅片要点

  • 作者认为用碳酸铵制备的聚乳酸微泡在合适参数下爆破有潜力通过靶向超声安全改善脊髓损伤的鞘内治疗递送。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We believe our poly(lactic acid) (PLA) microbubbles are well suited for therapeutic delivery to spinal cord injury (SCI) using ultrasound-triggered bursting. We investigated the feasibility of clinical ultrasound bursting in situ, the optimal bursting parameters in vitro and the loading and release of a model bio-active DNA.

METHODS: Microbubbles were tested using clinical ultrasound in a rat cadaver SCI model. Burst pressure thresholds were determined using the change in enhancement after ultrasound exposure. Resonance frequency, acoustic enhancement, sizing and morphology were evaluated by comparing two microbubble porogens, ammonium carbonate and ammonium carbamate. Oligonucleotides were loaded into the shell and released using the found optimized ultrasound bursting parameters.

RESULTS: In situ imaging and bursting were successful. In vitro bursting thresholds using frequencies 1, 2.25 and 5 MHz were identified between peak negative pressures 0.2 and 0.5 MPa, believed to be safe for spinal cord. The pressure threshold decreased with decreasing frequencies. PLA bursting was optimized near the resonance frequency of 2.5 to 3.0 MHz using 2.25 MHz and not at lower frequencies. PLA microbubbles, initially with a mean size of approximately 2 µm, remained in one piece, collapsed to between 0.5 and 1 µm and did not fragment. Significantly more oligonucleotide was released after ultrasound bursting of loaded microbubbles. Microbubble-sized debris was detected when using ammonium carbamate, leading to inaccurate microbubble concentration measurements.

CONCLUSION: PLA microbubbles made with ammonium carbonate and burst at appropriate parameters have the potential to safely improve intrathecal therapeutic delivery to SCI using targeted ultrasound.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Oeffinger BE, Stanczak M, Lepore AC, et al. Determining Ultrasound Parameters for Bursting Polymer Microbubbles for Future Use in Spinal Cord Injury. Ultrasound Med Biol. 2024. PMID: 38519360. doi:10.1016/j.ultrasmedbio.2024.02.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。