本文报道一例73岁女性在后循环动脉瘤弹簧圈栓塞术中经神经监测发现延髓和颈髓对比剂诱导脑病(CIE),可能与椎动脉置入远端通路导管后灌注压降低及术中多次注射对比剂有关,提示后循环血管内治疗中需高度警惕并利用神经监测早期发现神经功能变化。

要点

  • 后循环血管内治疗中对比剂诱导脑病可累及延髓和颈髓,神经监测有助于早期发现。
  • 椎动脉置入远端通路导管后灌注压降低可能促发脊髓缺血。
  • 术中造影可能无法显示所有异常,神经监测对发现神经功能变化很有用。

核心结论

  • 后循环血管内治疗中对比剂诱导脑病发生率相对较高且可导致穿支梗死等严重后果,需极度谨慎;神经监测对早期发现神经功能变化非常有用,尤其因术中造影可能无法显示所有异常。

研究设计与样本

  • 病例报告:73岁女性,因未破裂左侧基底动脉-小脑上动脉及基底动脉尖动脉瘤行弹簧圈栓塞术,术中通过神经监测发现延髓和颈髓对比剂诱导脑病。

临床应用与阅片要点

  • 作者认为后循环血管内治疗中需极度谨慎,因对比剂诱导脑病发生率相对较高且可导致穿支梗死等严重后果;神经监测对早期发现神经功能变化非常有用,尤其因术中造影可能无法显示所有异常。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Understanding the risks of contrast-induced encephalopathy (CIE), a serious complication of contrast agents, is crucial in endovascular treatment. We present the case of a 73-year-old woman who developed CIE in the medulla and cervical cord during coil embolization for unruptured left basilar-superior cerebellar artery and basilar artery tip aneurysms. The CIE was identified via neuromonitoring. In this case, spinal cord ischemia might have occurred due to reduced perfusion pressure after inserting the distal access catheter (DAC) in the vertebral artery. Multiple injections of contrast medium via the DAC during coil embolization likely contributed to an unusual form of CIE. Extreme caution is warranted during endovascular treatments involving the posterior circulation, due to the relatively high incidence of contrast-mediated encephalopathy, which can lead to severe consequences such as perforator infarction. Neuromonitoring is very useful for the early detection of neurological changes, particularly because intraoperative angiography may not reveal all irregularities.

来源:Neuroradiology,查看原文。版权归原作者所有。