CT引导介入中实时剂量可视化对放射科医生辐射剂量的影响:单中心评估
本研究在单中心评估CT引导介入中实时剂量可视化是否降低参与放射科医生的辐射剂量。共分析29名放射科医生、304次介入的517次剂量测量,结果显示实验组平均总辐射剂量降低58.1%(11.6 vs 4.86 μSv,p=0.034),助手角色降低最显著达78.5%(p=0.002)。结论认为实时剂量可视化可显著降低参与医生的辐射暴露。
要点
- 实时剂量可视化使参与CT介入的放射科医生平均总辐射剂量降低58.1%。
- 助手角色的剂量降低最显著,达78.5%。
- 实时屏幕显示与助手角色是剂量降低的独立影响因素。
核心结论
- CT介入中实时可视化主动辐射剂量可使参与放射科医生的辐射剂量显著降低。
研究设计与样本
- 单中心评估研究,使用RaySafe i2系统在常规防护围裙外佩戴专用剂量计,以1秒间隔记录剂量。
- 共分析29名放射科医生在304次经皮CT引导介入中的517次测量,其中249次有实时屏幕、268次无实时屏幕。
- 多数介入为微波消融(n=280),采用描述性统计和混合效应模型比较组间差异。
诊断标准与关键数值
- 实验组(有实时屏幕)平均总辐射剂量为4.86 μSv,对照组为11.6 μSv,降低58.1%(p=0.034)。
- 助手角色辐射剂量降低78.5%(15.55 vs 3.35 μSv,p=0.002)。
- 亚组分析显示使用实时屏幕总体显著降低剂量(p<0.0001),助手角色单独具有统计学显著影响(p=0.002)。
临床应用与阅片要点
- 在CT引导介入中引入实时剂量显示屏幕,可帮助操作者和助手即时调整站位与防护,降低个人剂量。
- 助手岗位的剂量降低幅度最大,应特别关注助手在术中的位置和实时剂量反馈。
局限性
- 本研究为单中心评估,样本来自单一机构,结论外推需谨慎。
- 研究未采用随机分组,对照组与实验组为先后两个研究期,可能存在时间偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate if real-time dose visualisation during computed tomography (CT)-guided interventions leads to a reduction in radiation dose to participating radiologists.
MATERIALS AND METHODS: The individual radiation dose radiologists are exposed to during CT interventions was measured using dedicated dosimeters (RaySafe i2-system, Unfors RaySafe GmbH, Billdal, Sweden) worn over the usual radiation protective apron. Initially, only the total radiation dose was measured, without visualisation (control group). In the following study period, the radiation dose was shown to participants on a live screen in real-time (experimental group). In both groups, the dose was recorded in 1-second intervals. The results collected were evaluated by comparison using descriptive statistics and mixed-effect models. In particular, the variables experience, gender, role, and position during the intervention were analysed.
RESULTS: In total, 517 measurements of 304 interventions (n=249 with and n=268 without live screen) performed by 29 radiologists acting as interventionalists or assistants were analysed. All CT-guided interventions were performed percutaneously, the majority of which (n=280) were microwave ablations (MWA). Radiation doses in the group without visualisation were comparable with usual dose rates for the corresponding intervention type. The mean total radiation dose was reduced by 58.1% (11.6 versus 4.86 μSv) in the experimental group (p=0.034). The highest reduction of 78.5% (15.55 versus 3.35 μSv) was observed in radiologists with the role of assistant (p=0.002). Sub-analysis showed significant dose reduction (p<0.0001) for the use of live screen in general; considering all variables, the role "assistant" alone had a statistically significant influence (p=0.002).
CONCLUSION: The real-time visualisation of active radiation dose during CT interventions leads to a relevant reduction in radiation dose to participating radiologists.
引用
- Koch A, Gruber-Rouh T, Zangos S, et al. Radiation protection in CT-guided interventions: does real-time dose visualisation lead to a reduction in radiation dose to participating radiologists? A single-centre evaluation. Clin Radiol. 2024. PMID: 38388255. doi:10.1016/j.crad.2024.01.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。