文献速递骨肌CT

光子计数探测器CT与能量积分探测器CT在舟骨骨折诊断及随访中的图像质量与诊断信心比较研究

A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT.
PubMed 文献 · Eur J Radiol · 2024-02-17

本研究对8例舟骨骨折患者在第1周及第4、6、8周分别行EID-CT和PCD-CT扫描,比较骨折可见性、愈合评估及图像质量。PCD-CT在骨小梁和骨皮质锐利度上优于EID-CT,骨折线可见性和诊断信心更高,但愈合评估两者等效。

要点

  • PCD-CT可提供更优的骨微结构显示和骨折线可见性。
  • 骨折愈合评估和诊断信心在PCD-CT与EID-CT间等效。
  • PCD-CT图像噪声更高、CNR更低,但主观图像质量仍评为更优。

核心结论

  • PCD-CT在显示骨微结构方面优于EID-CT,尤其提高了一周内骨折线的可见性和诊断信心,但骨折愈合评估两者等效。

研究设计与样本

  • 前瞻性自身对照研究,纳入8例舟骨骨折患者,在第1周及第4、6、8周分别行EID-CT和PCD-CT扫描。
  • EID-CT采用临床协议(CTDIvol 3.1 ± 0.1 mGy,UHR kernel Ur77),PCD-CT采用匹配辐射剂量和Br89重建核。
  • 由5名放射科医生对图像进行主观评估,包括骨折可见性、骨折间隙愈合和图像质量,并评分诊断信心。

关键影像表现/征象

  • PCD-CT图像的骨小梁和骨皮质锐利度优于EID-CT。
  • 两种系统均显示制动期间骨小梁骨体积分数逐渐降低。
  • PCD-CT图像噪声更高、CNR更低,但放射科医生主观评价图像质量更优。
  • 创伤后1周内骨折线可见性PCD-CT评分更高,诊断信心也更高。
  • 愈合过程中骨折间隙愈合评估和诊断信心两种系统等效。

临床应用与阅片要点

  • 在舟骨骨折急性期诊断中,可优先选用PCD-CT以提高骨折线可见性和诊断信心。
  • 随访评估骨折愈合时,PCD-CT与EID-CT可等效使用,无需因愈合评估目的而特别选择PCD-CT。
  • 需注意PCD-CT图像噪声较高、CNR较低,但主观图像质量仍可接受。

局限性

  • 样本量小(8例患者),可能影响统计效能和结论外推。
  • 单中心研究,设备协议和评估者主观性可能影响结果。
  • 仅评估舟骨骨折,结论不适用于其他部位骨折。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Scaphoid fractures in patients and assessment of healing using PCD-CT have, as far as we know, not yet been studied. Therefore, the aim was to compare photon counting detector CT (PCD-CT) with energy integrating detector CT (EID-CT) in terms of fracture visibility and evaluation of fracture healing.

METHOD: Eight patients with scaphoid fracture were examined with EID-CT and PCD-CT within the first week post-trauma, and with additional scans at 4, 6 and 8 weeks. Our clinical protocol for wrist examination with EID-CT was used (CTDIvol 3.1 ± 0.1 mGy, UHR kernel Ur77). For PCD-CT matched radiation dose, reconstruction kernel Br89. Quantitative analyses of noise, CNR, trabecular and cortical sharpness, and bone volume fraction were conducted. Five radiologists evaluated the images for fracture visibility, fracture gap consolidation and image quality, and rated their confidence in the diagnosis.

RESULTS: The trabecular and cortical sharpness were superior in images obtained with PCD-CT compared with EID-CT. A successive reduction in trabecular bone volume fraction during the immobilized periods was found with both systems. Despite higher noise and lower CNR with PCD-CT, radiologists rated the image quality of PCD-CT as superior. The visibility of the fracture line within 1-week post-trauma was rated higher with PCD-CT as was diagnostic confidence, but the subsequent assessments of fracture gap consolidation during healing process and the confidence in diagnosis were found equivalent between both systems.

CONCLUSION: PCD-CT offers superior visibility of bone microstructure compared with EID-CT. The evaluation of fracture healing and confidence in diagnosis were rated equally with both systems, but the radiologists found primary fracture visibility and overall image quality superior with PCD-CT.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kämmerling N, Tesselaar E, Booij R, et al. A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT. Eur J Radiol. 2024. PMID: 38377892. doi:10.1016/j.ejrad.2024.111383

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。