深度学习和几何图像组合重建改进腰骶丛三维DESS磁共振神经成像

Improved 3D DESS MR neurography of the lumbosacral plexus with deep learning and geometric image combination reconstruction.
PubMed 文献 · Skeletal Radiol · 2024-02-22

前瞻性纳入40例成人患者行3.0T腰骶丛DESS磁共振神经成像,比较有无深度学习及几何图像组合重建的图像质量与神经显示度。DESS GIC DL相对信噪比更优,DESS S2 DL神经-背景对比度更优;DESS血管抑制和坐骨神经束状结构显示优于STIR-T2w DL但运动伪影更多,DESS GIC DL对较小远端神经段显示更好。

要点

  • DESS GIC DL重建在腰骶丛磁共振神经成像中相对信噪比最优(p<0.001)。
  • DESS S2 DL的神经-背景对比度优于其他重建(p值范围0.002至<0.001)。
  • DESS GIC DL对较小远端神经段的显示优于DESS S2 DL和STIR-T2w DL。

核心结论

  • 在DESS磁共振神经成像中应用深度学习重建联合几何图像组合可改善腰骶丛神经显示度,尤其对较小分支神经。

研究设计与样本

  • 前瞻性研究,纳入40例成人患者(22例女性,平均年龄48.6±18.5岁),行3.0T腰骶丛DESS磁共振神经成像,部分患者加扫三维T2加权短tau反转恢复序列(STIR-T2w)。

关键影像表现/征象

  • DESS序列血管抑制和坐骨神经束状结构显示优于STIR-T2w DL,但整体运动伪影更多。
  • DESS GIC DL对多个较小远端神经段的神经显示优于DESS S2 DL和STIR-T2w DL。

诊断标准与关键数值

  • DESS GIC DL相对信噪比最优(p<0.001)。
  • DESS S2 DL神经-背景对比度最优(p值范围0.002至<0.001)。
  • 三名放射科医师对4组图像(DESS S2、DESS S2 DL、DESS GIC DL、STIR-T2w DL)就整体运动、血管抑制、神经束状结构及整体神经显示度进行评分。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the impact of deep learning (DL) reconstruction in enhancing image quality and nerve conspicuity in LSP MRN using DESS sequences. Additionally, a geometric image combination (GIC) method to improve DESS signals' combination was proposed.

MATERIALS AND METHODS: Adult patients undergoing 3.0 Tesla LSP MRN with DESS were prospectively enrolled. The 3D DESS echoes were separately reconstructed with and without DL and DL-GIC combined reconstructions. In a subset of patients, 3D T2-weighted short tau inversion recovery (STIR-T2w) sequences were also acquired. Three radiologists rated 4 image stacks ('DESS S2', 'DESS S2 DL', 'DESS GIC DL' and 'STIR-T2w DL') for bulk motion, vascular suppression, nerve fascicular architecture, and overall nerve conspicuity. Relative SNR, nerve-to-muscle, -fat, and -vessel contrast ratios were measured. Statistical analysis included ANOVA and Wilcoxon signed-rank tests. p < 0.05 was considered statistically significant.

RESULTS: Forty patients (22 females; mean age = 48.6 ± 18.5 years) were enrolled. Quantitatively, 'DESS GIC DL' demonstrated superior relative SNR (p < 0.001), while 'DESS S2 DL' exhibited superior nerve-to-background contrast ratio (p value range: 0.002 to < 0.001). Qualitatively, DESS provided superior vascular suppression and depiction of sciatic nerve fascicular architecture but more bulk motion as compared to 'STIR-T2w DL'. 'DESS GIC DL' demonstrated better nerve visualization for several smaller, distal nerve segments than 'DESS S2 DL' and 'STIR-T2w DL'.

CONCLUSION: Application of a DL reconstruction with geometric image combination in DESS MRN improves nerve conspicuity of the LSP, especially for its smaller branch nerves.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Lin Y, Tan ET, Campbell G, et al. Improved 3D DESS MR neurography of the lumbosacral plexus with deep learning and geometric image combination reconstruction. Skeletal Radiol. 2024. PMID: 38386108. doi:10.1007/s00256-024-04613-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。