文献速递骨肌介入CTUSDR

疑似恶性骨病变影像引导粗针活检的诊断效能:单学术机构的回顾性队列研究

Diagnostic efficacy of image-guided core needle biopsy of suspected malignant osseous lesions: a retrospective cohort study from a single academic institution.
PubMed 文献 · Eur Radiol · 2024-02-22

回顾性分析2010至2021年2321例疑似恶性骨病变的影像引导粗针活检,诊断产出率98.2%(2279/2321),准确率97.6%(120/123)。总芯长增加、芯数增加及存在原发恶性肿瘤与产出率提高相关,肢体部位和透视引导与产出率降低相关;总芯长20 mm和3条芯为优化产出率的阈值。

要点

  • 疑似恶性骨病变影像引导粗针活检诊断产出率98.2%、准确率97.6%。
  • 总芯长增加(OR=2.34)和芯数增加(OR=1.51)与诊断产出率提高相关。
  • 总芯长20 mm和3条芯为与产出率提高相关的阈值。

核心结论

  • 影像引导粗针活检对疑似恶性骨病变具有很高的诊断产出率和准确率;总芯长20 mm和3条芯可优化产出率,分析的因素均未影响诊断准确率。

研究设计与样本

  • 单学术机构回顾性队列研究,分析2010至2021年2321例影像引导粗针活检,采用多变量统计分析患者、病变及技术因素与产出率和准确率的关系。

诊断标准与关键数值

  • 诊断产出率98.2%(2279/2321),准确率97.6%(120/123);总芯长增加OR=2.34(95%CI 1.41-3.90,p=0.001),芯数增加OR=1.51(95%CI 1.06-2.16,p=0.02),存在原发恶性肿瘤OR=2.81(95%CI 1.40-5.62,p=0.004);肢体部位OR=0.27(95%CI 0.11-0.68,p=0.006),透视引导OR=0.33(95%CI 0.12-0.90,p=0.03);总芯长20 mm阈值边缘OR=4.16(95%CI 2.09-9.03,p<0.001),3条芯阈值边缘OR=2.78(95%CI 1.34-6.54,p=0.005)。

临床应用与阅片要点

  • 作者结论认为获取20 mm总芯长和3条芯可优化诊断产出率;存在原发恶性肿瘤与产出率提高相关,肢体部位和透视引导与产出率降低相关,分析的因素均未影响诊断准确率。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate diagnostic yield and accuracy of image-guided core needle biopsy (ICNB) of suspected malignant osseous lesions in a large cohort of adults, evaluate what factors influence these measures, and offer technical recommendations to optimize yield.

METHODS: A retrospective analysis of 2321 ICNBs performed from 2010 to 2021 was completed. The diagnostic yield and accuracy of the biopsies as well as a series of patient, lesion-related, and technical factors were retrospectively analyzed. Multivariate statistical analysis was performed to evaluate what factors were associated with yield and accuracy. Different cutoff values of total core length and core number were then tested to determine threshold values in relation to increased diagnostic yield.

RESULTS: Diagnostic yield was 98.2% (2279/2321) and accuracy was 97.6% (120/123). Increased total core length (odds ratio [OR] = 2.34, 95% confidence interval [CI] (1.41-3.90), p = 0.001), core number (OR = 1.51, 95% CI (1.06-2.16), p = 0.02) and presence of primary malignancy (OR = 2.81, 95% CI (1.40-5.62), p = 0.004) were associated with improved yield. Lesion location in an extremity (OR = 0.27, 95% CI (0.11-0.68), p = 0.006) and using fluoroscopic imaging guidance (OR = 0.33, 95% CI (0.12-0.90), p = 0.03) were associated with lower yield. Cutoff thresholds in relation to increased diagnostic yield were found to be 20 mm total core length (marginal OR = 4.16, 95% CI = (2.09-9.03), p < 0.001), and three total cores obtained (marginal OR = 2.78, 95% CI (1.34-6.54), p = 0.005). None of the analyzed factors influenced diagnostic accuracy.

CONCLUSIONS: ICNB has a high rate of diagnostic yield and accuracy. Several factors influence diagnostic yield; 20 mm core length and three total cores optimize yield.

CLINICAL RELEVANCE STATEMENT: Image-guided core needle biopsy of suspected malignant osseous lesions is a safe procedure with a very high rate of diagnostic yield and accuracy. Obtaining 20 mm total core length and three total cores optimizes diagnostic yield.

KEY POINTS: • In a retrospective cohort study, image-guided core needle biopsy of suspected osseous malignant lesions in adults was found to have very high rates of diagnostic yield and accuracy. • Increased total core length and core number of biopsies were each associated with increased diagnostic yield, and these relationships reached thresholds at 20 mm total core length and three total cores obtained. • The presence of a known primary malignancy was also associated with increased yield while using fluoroscopic imaging guidance and lesion location in an extremity were associated with decreased yield.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Winkler WL, Baker JC, Tomasian A, et al. Diagnostic efficacy of image-guided core needle biopsy of suspected malignant osseous lesions: a retrospective cohort study from a single academic institution. Eur Radiol. 2024. PMID: 38388720. doi:10.1007/s00330-024-10663-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。