光子计数探测器CT血管造影与数字减影血管造影在外周动脉疾病患者中的比较
本研究以数字减影血管造影(DSA)为诊断参考标准,在39例患者45条下肢光子计数探测器CT血管造影(PCD-CTA)中比较三种血管重建核(Bv36/48/56)的诊断置信度;Bv56核可减轻钙化伪影、提高血管锐利度,诊断置信度最高,狭窄分级与DSA的一致性也提高。
要点
- Bv56锐核可减轻钙化伪影、提高血管锐利度,诊断置信度最高。
- 各核狭窄定量敏感度相近(81.6% vs 81.5% vs 81.0%,p=0.797)。
- 严重钙化胫动脉特异度明显下降,Bv56核可改善(Bv36 vs Bv56 p=0.024)。
核心结论
- 下肢PCD-CTA中,锐卷积核通过改善血管勾画和减少钙化伪影、且图像噪声可接受,较DSA提高诊断置信度。
研究设计与样本
- 同组患者自身对照研究,39例患者共45条下肢PCD-CTA并随后行DSA,以DSA为诊断参考标准,CTA后处理采用Bv36/48/56三种血管核。
关键影像表现/征象
- 管腔衰减不随核变化而保持恒定;核越锐图像噪声明显增加,SNR和CNR下降;Bv56锐核主观钙化伪影减少、血管锐利度提高。
诊断标准与关键数值
- 狭窄定量敏感度Bv36 81.6% vs Bv48 81.5% vs Bv56 81.0%(p=0.797);特异度Bv36 71.1% vs Bv48 76.9% vs Bv56 79.6%(p=0.067);Bv36与Bv56狭窄分级与DSA一致性比较p=0.002;严重钙化胫血管特异度Bv36 vs Bv56 p=0.024。
临床应用与阅片要点
- 阅片及报告下肢PCD-CTA时可选用Bv56锐核以改善血管勾画、减少钙化伪影并提高诊断置信度;严重钙化胫动脉处特异度下降,Bv56核可改善。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD).
MATERIAL AND METHODS: In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.8% of patients. CTA post-processing comprised three vascular kernels (Bv36/48/56). Objective image quality assessment included vessel attenuation, image noise, contrast-to-noise (CNR) and signal-to-noise ratios (SNR). Subjective evaluation of calcium blooming, vessel sharpness, luminal attenuation and image noise was performed by three radiologists. Diagnostic performance and concordance to DSA were assessed.
RESULTS: The luminal attenuation remained kernel-independent constant. With sharper kernels, image noise increased substantially, while SNR and CNR decreased. Subjective reduction of calcium blooming and increased vessel sharpness were noted for the sharp Bv56 kernel. While sensitivity in stenosis quantification was comparable between kernels (81.6% vs. 81.5% vs. 81.0%, p = 0.797), specificity increased slightly higher sharpness (71.1% vs. 76.9% vs. 79.6%, p = 0.067). Diagnostic concordance of stenosis ratings compared to DSA increased likewise (Bv36 vs. Bv56, p = 0.002). Severe crural vessel calcifications had no influence on sensitivity, regardless of kernel selection. Contrarily, specificity was substantially worse in severely calcified tibial vessels but could be improved by using the sharp Bv56 kernel (Bv36 vs. Bv56 p = 0.024). Diagnostic confidence was highest for Bv56.
CONCLUSION: In lower leg PCD-CTA, sharp convolution kernels increase diagnostic confidence compared to DSA by improved vessel delineation and reduced calcium blooming with acceptable image noise.
引用
- Augustin AM, Hartung V, Grunz JP, et al. Photon-Counting Detector CT Angiography Versus Digital Subtraction Angiography in Patients with Peripheral Arterial Disease. Acad Radiol. 2024. PMID: 38403477. doi:10.1016/j.acra.2024.02.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。