儿童髋关节MRI合成CT与常规CT的形态学与临床对比研究
该前瞻性研究纳入19例患者38个髋关节,对比3T MRI生成的合成CT与常规CT在儿童髋关节形态和成熟度评估中的等效性。结果显示两种方法形态学测量具有统计学等效性(P<0.05),平均差异<2°,表面距离0.23±0.18 mm,骨骺成熟度判定准确率98.4%,合成CT信噪比更高,总体诊断质量无显著差异。
要点
- 合成CT与常规CT髋关节形态学测量具有统计学等效性,平均差异<2°。
- 合成CT判定骨骺成熟度准确率98.4%(242/246,95%CI 96.0-99.6),以常规CT为参考标准。
- 合成CT信噪比高于常规CT(P<0.001),总体诊断质量、骨边缘清晰度、皮质髓质分化和伪影无显著差异。
核心结论
- 在儿童患者中,合成CT在髋关节形态、骨骺状态和放射密度评估方面与常规CT等效。
研究设计与样本
- 前瞻性研究,纳入19例患者共38个髋关节(年龄16.6±3岁,范围9.9-20.9岁;男性5例),采用3T MRI双回波梯度回波序列经商用后处理软件(BoneMRI v1.5研究版,MRIguidance BV,荷兰乌得勒支)生成合成CT,以常规CT为参考标准,由两名儿童肌肉骨骼放射科医师测量7项髋关节形态学参数。
诊断标准与关键数值
- 合成CT与常规CT形态学测量组间和组内ICC为0.77<ICC<0.98,等效性检验P<0.05,平均组间差异<2°;三维表面距离平均0.23±0.18 mm;骨骺成熟度判定准确率98.4%(242/246,95%CI 96.0-99.6),以常规CT为参考标准,在7个位置评估骨骺状态。
临床应用与阅片要点
- 合成CT可用于儿童髋关节形态和骨骺成熟度的评估,其信噪比高于常规CT,骨边缘清晰度、皮质髓质分化和伪影与常规CT无显著差异,HU值在合成CT和常规CT上均在参考值范围内。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: MRI-based synthetic CT (sCT) generates CT-like images from MRI data.
OBJECTIVE: To evaluate equivalence, inter- and intraobserver reliability, and image quality of sCT compared to conventional (cCT) for assessing hip morphology and maturity in pediatric patients.
MATERIALS AND METHODS: We prospectively enrolled patients <21 years old with cCT and 3T MRI of the hips/pelvis. A dual-echo gradient-echo sequence was used to generate sCT via a commercially available post-processing software (BoneMRI v1.5 research version, MRIguidance BV, Utrecht, NL). Two pediatric musculoskeletal radiologists measured seven morphologic hip parameters. 3D surface distances between cCT and sCT were computed. Physeal status was established at seven locations with cCT as reference standard. Images were qualitatively scored on a 5-point Likert scale regarding diagnostic quality, signal-to-noise ratio, clarity of bony margin, corticomedullary differentiation, and presence and severity of artifacts. Quantitative evaluation of Hounsfield units (HU) was performed in bone, muscle, and fat tissue. Inter- and intraobserver reliability were measured by intraclass correlation coefficients. The cCT-to-sCT intermodal agreement was assessed via Bland-Altman analysis. The equivalence between modalities was tested using paired two one-sided tests. The quality parameter scores of each imaging modality were compared via Wilcoxon signed-rank test. For tissue-specific HU measurements, mean absolute error and mean percentage error values were calculated using the cCT as the reference standard.
RESULTS: Thirty-eight hips in 19 patients were included (16.6 ± 3 years, range 9.9-20.9; male = 5). cCT- and sCT-based morphologic measurements demonstrated good to excellent inter- and intraobserver correlation (0.77<ICC<0.98). Measurements were statistically equivalent (P < 0.05), with average intermodal differences <2°. Mean surface distance between cCT and sCT was 0.23 ± 0.18 mm. Accuracy to determine physeal maturity status by sCT was 98.4% (242/246, 95% CI 96.0-99.6). No significant differences were found on overall diagnostic quality, bony margin clarity, corticomedullary differentiation, and artifacts between sCT and cCT; signal-to-noise ratio was higher on sCT (P < 0.001). HU were within reference values on both sCT and cCT.
CONCLUSION: sCT is equivalent to cCT for the assessment of hip morphology, physeal status, and radiodensity assessment in pediatric patients.
引用
- Iwasaka-Neder J, Bedoya MA, Connors J, et al. Morphometric and clinical comparison of MRI-based synthetic CT to conventional CT of the hip in children. Pediatr Radiol. 2024. PMID: 38421417. doi:10.1007/s00247-024-05888-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。