同相位与反相位Dixon化学位移成像评估骨骼骨髓病变:纵向序列与轴向序列测量值的比较
研究纳入96例疑似骨肿瘤患者共100个病灶,比较纵向(冠状或矢状)与轴向化学位移成像测量值。9%-14%病例出现脂肪含量分类差异,但纵向平面诊断准确率79%、轴向平面75%-80%,差异对总体诊断准确率无明显影响。
要点
- 不同平面化学位移成像测量值在9%-14%病灶中存在显著差异。
- 纵向平面诊断准确率为79%,轴向平面为75%-80%。
- 平面间测量差异对总体诊断准确率无明显影响。
核心结论
- 基于成像平面的化学位移成像测量值在9%-14%病例中出现显著差异,但对诊断准确率无明显影响。
研究设计与样本
- 连续纳入96例疑似骨肿瘤患者共100个病灶,行同相位与反相位化学位移成像,脊柱病灶取矢状与轴向平面、其他部位取冠状与轴向平面,参考标准为典型影像特征(n=57)或组织学(n=43)。
关键影像表现/征象
- 纵向平面将病灶分类为含脂肪(信号强度下降>20%-25%)而轴向平面分类为脂肪替代(信号强度下降<20%-25%),或反之,见于9%-14%病例。
诊断标准与关键数值
- 含脂肪判定为信号强度下降>20%-25%,脂肪替代判定为信号强度下降<20%-25%。
- 纵向平面诊断准确率79%,轴向平面诊断准确率75%-80%。
- 100个病灶中非肿瘤性22个(22%)、良性肿瘤44个(44%)、中间级别肿瘤6个(6%)、恶性肿瘤28个(28%)。
临床应用与阅片要点
- 放射科医生应知晓不同平面化学位移成像测量值在高达14%的病灶中似乎存在显著差异。
- 诊断准确率似乎未受平面间测量差异的显著影响。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: In-phase and opposed-phase chemical shift imaging (CSI) is a useful technique for assessing skeletal lesions. This study determined the frequency of significant differences in measurements obtained from longitudinal (coronal or sagittal) sequences to those obtained from axial sequences.
METHODS: Chemical shift imaging was undertaken in 96 consecutive patients referred from the Musculoskeletal Sarcoma and Spinal Oncology services for assessment of possible bone tumours as part of a standard tumour protocol, which included turbo spin echo and inversion recovery sequences. For spinal lesions, CSI was obtained in the sagittal and axial planes, while for all other sites, it was obtained in the coronal and axial planes.
RESULTS: The study included 49 (51.0%) males and 47 (49.0%) females with mean age 42.4 years (range 2-91 years). In 4 cases, 2 individual lesions were assessed, making a total of 100 lesions. Based on typical imaging features (n = 57) or histology (n = 43), 22 lesions (22%) were classified as non-neoplastic, 44 (44%) as benign neoplasms, 6 (6%) as intermediate-grade neoplasms, and 28 (28%) as malignant neoplasms. A significant discrepancy, wherein a lesion was classified as fat-containing (% SI drop >20%-25%) in the longitudinal plane, while in the axial plane it was classified as fat-replacing (% SI drop <20%-25%), or vice versa, occurred in 9%-14% of cases. However, this discrepancy had no appreciable effect on overall diagnostic accuracy, which was calculated at 79% for the longitudinal plane and 75%-80% for the axial plane.
CONCLUSIONS: Significant differences in CSI measurements occur in 9%-14% of cases based on imaging plane, but with no significant effect on diagnostic accuracy.
ADVANCES IN KNOWLEDGE: Radiologists should be aware that CSI measurements in different planes appear to have significant differences in up to 14% of lesions. However, diagnostic accuracy does not seem to be significantly affected.
引用
- Saifuddin A, Ali M, Santiago R, et al. In-phase and opposed-phase Dixon chemical shift imaging for the assessment of skeletal marrow lesions: comparison of measurements from longitudinal sequences to those from axial sequences. Br J Radiol. 2024. PMID: 38321150. doi:10.1093/bjr/tqae031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。