文献速递骨肌MR

屈肘、肩外展、前臂旋后(FABS)位三维肘关节MRI重建:肱二头肌头解剖与病变的诊断性能评估

Flexed elbow, abducted shoulder, forearm supinated (FABS) reconstruction from three-dimensional elbow MRI: diagnostic performance assessment in biceps head anatomy and pathology.
PubMed 文献 · Clin Radiol · 2024-01-13

研究对48例肘关节三维各向同性MRI进行数字化虚拟FABS位重建,由6名肌骨放射科医师独立评估肱二头肌肌腱完整性、两头可见性、撕裂类型及回缩程度。FABS重建全部成功,肌腱完整性、两头可见性、撕裂类型的Kappa分别为0.66、0.24、0.55,回缩程度ICC为0.85(含无回缩)和0.78(仅有回缩),撕裂vs无撕裂AUC为0.82至0.96,结论为FABS重建可行且对单个肌腱头撕裂和回缩评估良好。

要点

  • FABS重建在全部48例中成功获得,可用于评估肱二头肌远端肌腱各头。
  • 肌腱完整性Kappa 0.66,撕裂类型Kappa 0.55,两头可见性Kappa仅0.24。
  • 回缩程度ICC 0.85(含无回缩肌腱)和0.78(仅含回缩肌腱)。

核心结论

  • 数字化FABS位重建可行,对单个肌腱头撕裂和回缩的评估良好,诊断性能高。

研究设计与样本

  • 由6名肌骨放射科医师独立评估肘关节MRI虚拟FABS重建图像,盲于临床发现和最终诊断,共48例。

关键影像表现/征象

  • FABS重建在全部48例中成功获得。
  • 评估内容包括肌腱是否完整、两头是否可见、撕裂类型及回缩程度(厘米)。

诊断标准与关键数值

  • 肌腱完整性Kappa 0.66(95%CI 0.53-0.78)。
  • 两头可见性Kappa 0.24(95%CI 0.12-0.37)。
  • 撕裂类型Kappa 0.55(95%CI 0.43-0.66)。
  • 回缩程度ICC 0.85(95%CI 0.79-0.91,含无回缩肌腱)和0.78(95%CI 0.61-0.91,仅含回缩肌腱)。
  • 撕裂vs无撕裂AUC 0.82(95%CI 0.74-0.89)至0.96(95%CI 0.91-1.01)。

临床应用与阅片要点

  • FABS重建可用于评估肱二头肌远端肌腱各头的撕裂及回缩程度。
  • 两头可见性的读者间一致性较低(Kappa 0.24),阅片时需注意。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To determine inter-reader analysis and diagnostic performance on digitally reconstructed virtual flexed, abducted, supinated (FABS) imaging from three-dimensional (3D) isotropic elbow magnetic resonance imaging (MRI).

MATERIALS AND METHODS: Six musculoskeletal radiologists independently evaluated elbow MRI images with virtual FABS reconstructions, blinded to clinical findings and final diagnoses. Each radiologist recorded a binary result as to whether the tendon was intact and if both heads were visible, along with a categorical value to the type of tear and extent of retraction in centimetres where applicable. Kappa and interclass correlation (ICC) were reported with 95% confidence intervals. Areas under the receiver operating curve (AUC) were reported.

RESULTS: FABS reconstructions were obtained successfully in all 48 cases. With respect to tendon intactness, visibility of both heads, and type of tear, the Kappa values were 0.66 (0.53-0.78), 0.24 (0.12-0.37), and 0.55 (0.43-0.66), respectively. For the extent of retraction, the ICC was 0.85 (0.79-0.91) when including the tendons with and without retraction and 0.78 (0.61-0.91) when only including tendons with retraction. For tear versus no tear, AUC values were 0.82 (0.74-0.89) to 0.96 (0.91-1.01).

CONCLUSION: Digital reconstruction of FABS positioning is feasible and allows good assessment of individual tendon head tears and retraction with high diagnostic performance.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Aggarwal VA, Thakur U, Silva FD, et al. Flexed elbow, abducted shoulder, forearm supinated (FABS) reconstruction from three-dimensional elbow MRI: diagnostic performance assessment in biceps head anatomy and pathology. Clin Radiol. 2024. PMID: 38341341. doi:10.1016/j.crad.2023.12.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。