屈肘、肩外展、前臂旋后(FABS)位三维肘关节MRI重建:肱二头肌头解剖与病变的诊断性能评估
研究对48例肘关节三维各向同性MRI进行数字化虚拟FABS位重建,由6名肌骨放射科医师独立评估肱二头肌肌腱完整性、两头可见性、撕裂类型及回缩程度。FABS重建全部成功,肌腱完整性、两头可见性、撕裂类型的Kappa分别为0.66、0.24、0.55,回缩程度ICC为0.85(含无回缩)和0.78(仅有回缩),撕裂vs无撕裂AUC为0.82至0.96,结论为FABS重建可行且对单个肌腱头撕裂和回缩评估良好。
要点
- FABS重建在全部48例中成功获得,可用于评估肱二头肌远端肌腱各头。
- 肌腱完整性Kappa 0.66,撕裂类型Kappa 0.55,两头可见性Kappa仅0.24。
- 回缩程度ICC 0.85(含无回缩肌腱)和0.78(仅含回缩肌腱)。
核心结论
- 数字化FABS位重建可行,对单个肌腱头撕裂和回缩的评估良好,诊断性能高。
研究设计与样本
- 由6名肌骨放射科医师独立评估肘关节MRI虚拟FABS重建图像,盲于临床发现和最终诊断,共48例。
关键影像表现/征象
- FABS重建在全部48例中成功获得。
- 评估内容包括肌腱是否完整、两头是否可见、撕裂类型及回缩程度(厘米)。
诊断标准与关键数值
- 肌腱完整性Kappa 0.66(95%CI 0.53-0.78)。
- 两头可见性Kappa 0.24(95%CI 0.12-0.37)。
- 撕裂类型Kappa 0.55(95%CI 0.43-0.66)。
- 回缩程度ICC 0.85(95%CI 0.79-0.91,含无回缩肌腱)和0.78(95%CI 0.61-0.91,仅含回缩肌腱)。
- 撕裂vs无撕裂AUC 0.82(95%CI 0.74-0.89)至0.96(95%CI 0.91-1.01)。
临床应用与阅片要点
- FABS重建可用于评估肱二头肌远端肌腱各头的撕裂及回缩程度。
- 两头可见性的读者间一致性较低(Kappa 0.24),阅片时需注意。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To determine inter-reader analysis and diagnostic performance on digitally reconstructed virtual flexed, abducted, supinated (FABS) imaging from three-dimensional (3D) isotropic elbow magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Six musculoskeletal radiologists independently evaluated elbow MRI images with virtual FABS reconstructions, blinded to clinical findings and final diagnoses. Each radiologist recorded a binary result as to whether the tendon was intact and if both heads were visible, along with a categorical value to the type of tear and extent of retraction in centimetres where applicable. Kappa and interclass correlation (ICC) were reported with 95% confidence intervals. Areas under the receiver operating curve (AUC) were reported.
RESULTS: FABS reconstructions were obtained successfully in all 48 cases. With respect to tendon intactness, visibility of both heads, and type of tear, the Kappa values were 0.66 (0.53-0.78), 0.24 (0.12-0.37), and 0.55 (0.43-0.66), respectively. For the extent of retraction, the ICC was 0.85 (0.79-0.91) when including the tendons with and without retraction and 0.78 (0.61-0.91) when only including tendons with retraction. For tear versus no tear, AUC values were 0.82 (0.74-0.89) to 0.96 (0.91-1.01).
CONCLUSION: Digital reconstruction of FABS positioning is feasible and allows good assessment of individual tendon head tears and retraction with high diagnostic performance.
引用
- Aggarwal VA, Thakur U, Silva FD, et al. Flexed elbow, abducted shoulder, forearm supinated (FABS) reconstruction from three-dimensional elbow MRI: diagnostic performance assessment in biceps head anatomy and pathology. Clin Radiol. 2024. PMID: 38341341. doi:10.1016/j.crad.2023.12.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。