本研究在2020年6月至2022年3月期间,采用历史对照与前瞻性评估,评价一款商业化人工智能软件对CT颈椎骨折的优先排序效果。共分析2973例患者(回顾性2036例,前瞻性938例),骨折总体患病率7.6%。前瞻性队列中,所有扫描的首次打开时间缩短18%(5分钟),骨折阳性扫描缩短46%(16分钟);AI总体敏感度89.8%、特异度95.3%、诊断准确率94.8%,但漏诊22处骨折,其中5处需稳定治疗。

要点

  • AI软件可缩短颈椎骨折CT诊断时间,骨折阳性病例缩短16分钟。
  • AI总体敏感度89.8%、特异度95.3%、阴性预测值99.1%。
  • AI漏诊22处骨折,其中5处需稳定治疗,提示临床相关骨折可能被遗漏。

核心结论

  • 引入AI后,骨折病例的诊断时间缩短16分钟;尽管AI辅助的工作流程优先排序在CT颈椎骨折检测中显示出高诊断准确率,但临床相关病例仍被漏诊。

研究设计与样本

  • 研究类型为历史对照与前瞻性评估;总样本2973例(回顾性2036例,前瞻性938例),平均年龄55.4±19.7岁,男性1857例;所有患者接受颈椎非增强CT;参考标准为常规临床工作流程中生成的放射学报告,并由一名高级放射科医生调整。

诊断标准与关键数值

  • AI总体敏感度89.8%(95%CI:84.2-94.0%),特异度95.3%(95%CI:94.2-96.2%),诊断准确率94.8%(95%CI:93.8-95.8%),阴性预测值99.1%(95%CI:98.5-99.4%),阳性预测值63.0%(95%CI:58.0-67.8%);骨折总体患病率7.6%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • AI漏诊22处骨折,其中5处需要稳定治疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Artificial intelligence (AI) applications can facilitate detection of cervical spine fractures on CT and reduce time to diagnosis by prioritizing suspected cases.

PURPOSE: To assess the effect on time to diagnose cervical spine fractures on CT and diagnostic accuracy of a commercially available AI application.

MATERIALS AND METHODS: In this study (June 2020 - March 2022) with historic controls and prospective evaluation, we evaluated regulatory-cleared AI-software to prioritize cervical spine fractures on CT. All patients underwent non-contrast CT of the cervical spine. The time between CT acquisition and the moment the scan was first opened (DNT) was compared between the retrospective and prospective cohorts. The reference standard for determining diagnostic accuracy was the radiology report created in routine clinical workflow and adjusted by a senior radiologist. Discrepant cases were reviewed and clinical relevance of missed fractures was determined.

RESULTS: 2973 (mean age, 55.4 ± 19.7 [standard deviation]; 1857 men) patients were analyzed by AI, including 2036 retrospective and 938 prospective cases. Overall prevalence of cervical spine fractures was 7.6 %. The DNT was 18 % (5 min) shorter in the prospective cohort. In scans positive for cervical spine fracture according to the reference standard, DNT was 46 % (16 min) shorter in the prospective cohort. Overall sensitivity of the AI application was 89.8 % (95 % CI: 84.2-94.0 %), specificity was 95.3 % (95 % CI: 94.2-96.2 %), and diagnostic accuracy was 94.8 % (95 % CI: 93.8-95.8 %). Negative predictive value was 99.1 % (95 % CI: 98.5-99.4 %) and positive predictive value was 63.0 % (95 % CI: 58.0-67.8 %). 22 fractures were missed by AI of which 5 required stabilizing therapy.

CONCLUSION: A time gain of 16 min to diagnosis for fractured cases was observed after introducing AI. Although AI-assisted workflow prioritization of cervical spine fractures on CT shows high diagnostic accuracy, clinically relevant cases were missed.