文献速递骨肌MR

炎性膝滑膜炎:加速FLAIR序列与标准增强成像的评估对比

Inflammatory Knee Synovitis: Evaluation of an Accelerated FLAIR Sequence Compared With Standard Contrast-Enhanced Imaging.
PubMed 文献 · Invest Radiol · 2024-02-08

本研究回顾性纳入55例疑似膝滑膜炎患者,在3T磁共振上比较深度学习加速的非增强FLAIR脂肪抑制序列(采集时间1分38秒)与作为参考标准的增强T1加权脂肪抑制序列(采集时间4分50秒)。全膝滑膜炎半定量评分在两者间无显著差异(FLAIR平均10.69±8.83 vs T1 turbo spin-echo FS 10.74±10.32,P=0.521),读者间和读者内重现性均优秀(Cohen κ范围0.82-0.96)。结论认为DL加速非增强FLAIR FS序列评估炎性膝滑膜炎可行且与增强T1加权FS成像等效。

要点

  • DL加速非增强FLAIR FS序列(1分38秒)与增强T1加权FS序列(4分50秒)的全膝滑膜炎评分无显著差异(P=0.521)。
  • 读者间和读者内重现性均优秀,Cohen κ范围0.82-0.96。
  • 55例中27例(49%)为轻至中度滑膜炎(评分6-13),17例(31%)为重度(评分>14),11例(20%)无滑膜炎征象(评分<5)。

核心结论

  • 使用DL加速非增强FLAIR FS序列评估炎性膝滑膜炎是可行的,且与增强T1加权FS成像等效。

研究设计与样本

  • 回顾性纳入2023年1月至9月间疑似膝滑膜炎患者55例(平均年龄52±17岁,女性28例),均行3T膝关节磁共振,包括DL加速非增强FLAIR FS序列(采集时间1分38秒)和作为参考标准的增强T1加权FS序列(采集时间4分50秒)。

诊断标准与关键数值

  • 采用半定量改良膝滑膜炎评分、积液滑膜炎评分和Hoffa炎症评分进行评分;全膝滑膜炎评分DL加速FLAIR平均10.69±8.83 vs 增强T1 turbo spin-echo FS平均10.74±10.32,P=0.521,无显著差异;读者间和读者内重现性Cohen κ范围0.82-0.96。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to assess the diagnostic value and accuracy of a deep learning (DL)-accelerated fluid attenuated inversion recovery (FLAIR) sequence with fat saturation (FS) in patients with inflammatory synovitis of the knee.

MATERIALS AND METHODS: Patients with suspected knee synovitis were retrospectively included between January and September 2023. All patients underwent a 3 T knee magnetic resonance imaging including a DL-accelerated noncontrast FLAIR FS sequence (acquisition time: 1 minute 38 seconds) and a contrast-enhanced (CE) T1-weighted FS sequence (acquisition time: 4 minutes 50 seconds), which served as reference standard. All knees were scored by 2 radiologists using the semiquantitative modified knee synovitis score, effusion synovitis score, and Hoffa inflammation score. Diagnostic confidence, image quality, and image artifacts were rated on separate Likert scales. Wilcoxon signed rank test was used to compare the semiquantitative scores. Interreader and intrareader reproducibility were calculated using Cohen κ.

RESULTS: Fifty-five patients (mean age, 52 ± 17 years; 28 females) were included in the study. Twenty-seven patients (49%) had mild to moderate synovitis (synovitis score 6-13), and 17 patients (31%) had severe synovitis (synovitis score >14). No signs of synovitis were detected in 11 patients (20%) (synovitis score <5). Semiquantitative assessment of the whole knee synovitis score showed no significant difference between the DL-accelerated FLAIR sequence and the CE T1-weighted sequence (mean FLAIR score: 10.69 ± 8.83, T1 turbo spin-echo FS: 10.74 ± 10.32; P = 0.521). Both interreader and intrareader reproducibility were excellent (range Cohen κ [0.82-0.96]).

CONCLUSIONS: Assessment of inflammatory knee synovitis using a DL-accelerated noncontrast FLAIR FS sequence was feasible and equivalent to CE T1-weighted FS imaging.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Feuerriegel GC, Goller SS, von Deuster C, et al. Inflammatory Knee Synovitis: Evaluation of an Accelerated FLAIR Sequence Compared With Standard Contrast-Enhanced Imaging. Invest Radiol. 2024. PMID: 38329824. doi:10.1097/RLI.0000000000001065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。