文献速递乳腺乳腺X线

对比增强乳腺X线摄影在乳腺浸润性小叶癌术前评估中的作用

The role of contrast-enhanced mammography in the preoperative evaluation of invasive lobular carcinoma of the breast.
PubMed 文献 · Clin Radiol · 2024-02-12

这项多中心、多厂商、跨国回顾性研究纳入115个浸润性小叶癌病灶,评估对比增强乳腺X线摄影(CEM)术前分期的表现。CEM对病灶的敏感度优于标准乳腺X线摄影,与病理大小的相关性更高(r=0.626 vs 0.295),对多灶性病变的敏感度为70%(标准乳腺X线摄影为20%),但CEM平均高估肿瘤大小1.5倍。作者认为CEM是小叶癌局部 staging 的有用工具,可能作为乳腺MRI的替代选择。

要点

  • CEM对浸润性小叶癌的敏感度优于标准乳腺X线摄影,19%的小叶癌不加对比剂不可见。
  • CEM与病理大小的相关性优于标准乳腺X线摄影(r=0.626 vs 0.295)。
  • CEM对多灶性病变的敏感度为70%,标准乳腺X线摄影为20%。

核心结论

  • CEM是小叶癌局部 staging 的有用工具,可能作为乳腺MRI的替代选择。

研究设计与样本

  • 多中心、多厂商、跨国回顾性研究,纳入2013年12月至2021年12月间经组织学诊断的浸润性小叶癌且接受CEM的女性,共115个病灶;对接受原发手术切除的女性与组织学数据进行比较。

关键影像表现/征象

  • 115个浸润性小叶癌病灶中,46个(40%)有症状,69个为筛查发现。
  • 19%的小叶癌不加对比剂不可见。
  • CEM对多灶性病变的敏感度为70%,标准乳腺X线摄影为20%(p<0.0001)。

诊断标准与关键数值

  • CEM与病理大小的相关系数r=0.626,标准乳腺X线摄影r=0.295(p=0.001)。
  • CEM对多灶性病变的敏感度为70%,标准乳腺X线摄影为20%(p<0.0001)。
  • CEM平均高估肿瘤大小1.5倍,肿瘤越大差异越明显。
  • 行MRI的22例中,MRI平均高估肿瘤大小1.3倍;CEM肿瘤大小平均比MRI大0.5 cm。

临床应用与阅片要点

  • CEM可用于小叶癌的局部 staging,作者认为可能作为乳腺MRI的替代选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the performance of contrast-enhanced mammography (CEM) in the preoperative staging of invasive lobular carcinoma (ILC) of the breast.

MATERIALS AND METHODS: The present study was a multicentre, multivendor, multinational retrospective study of women with a histological diagnosis of ILC who had undergone CEM from December 2013 to December 2021. Index lesion size and multifocality were recorded for two-dimensional (2D) mammography, CEM, and when available magnetic resonance imaging (MRI). Comparison with histological data was undertaken for women treated by primary surgical excision. Pearson correlation coefficients and Bland-Altman's analysis of agreement were used to assess differences with a significance level of 0.05.

RESULTS: One hundred and fifteen ILC lesions were included, 46 (40%) presented symptomatically and 69 were screening detected. CEM demonstrated superior sensitivity when compared to standard mammography. The correlation between the histological size measured on the surgical excision specimen size was greater than with standard mammography (r=0.626 and 0.295 respectively, p=0.001), with 19% of lobular carcinomas not visible without a contrast agent. The sensitivity of CEM for multifocal disease was greater than standard mammography (70% and 20% respectively, p<0.0001). CEM overestimated tumour size by an average of 1.5 times, with the size difference increasing for larger tumour. When MRI was performed (n=22), tumour size was also overestimated by an average of 1.3 times. The degree of size overestimation was similar for both techniques, with the tumour size on CEM being on average 0.5 cm larger than MRI.

CONCLUSION: CEM is a useful tool for the local staging of lobular carcinomas and could be an alternative to breast MRI.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Giannotti E, Van Nijnatten TJA, Chen Y, et al. The role of contrast-enhanced mammography in the preoperative evaluation of invasive lobular carcinoma of the breast. Clin Radiol. 2024. PMID: 38383254. doi:10.1016/j.crad.2024.01.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。