筛查性自动乳腺超声中横断面联合冠状面与单独横断面的诊断效能比较
回顾性纳入644例40-70岁女性的自动乳腺超声图像,四名新手与四名有经验放射科医师分别以横断面联合冠状面(T+C)和单独横断面(T)两种模式阅片。T+C模式平均阅片时间显著短于T模式(115±32 vs 128±31秒,P<.05),乳腺癌病灶显著度更高(OR 1.76,95%CI 1.00-3.08,P=.04),但以BI-RADS 3或4为阈值时敏感度、特异度及平均AUC在两种模式间均无显著差异。
要点
- T+C模式较T模式平均阅片时间缩短(115±32 vs 128±31秒,P<.05)。
- T+C模式乳腺癌病灶显著度更高(OR 1.76,95%CI 1.00-3.08,P=.04)。
- 两种模式诊断效能无显著差异,BI-RADS 3阈值敏感度82% vs 81%、特异度68% vs 70%。
核心结论
- 在自动乳腺超声筛查中增加冠状面可节省阅片时间并提高乳腺癌病灶显著度,但未提高诊断效能。
研究设计与样本
- 回顾性研究,纳入2016年1月至2020年10月间644例40-70岁女性(无异常组396例、良性病变组143例、恶性病变组105例)的自动乳腺超声图像;四名具有1-5年乳腺超声经验的新手放射科医师和四名具有>5年经验的有经验放射科医师,分别在独立阅片 session 中以横断面联合冠状面(T+C)和单独横断面(T)模式阅片;采用方差分析比较诊断效能、病灶显著度和阅片时间。
关键影像表现/征象
- T+C模式较T模式平均阅片时间显著缩短(115±32 vs 128±31秒,P<.05)。
- T+C模式较T模式乳腺癌病灶显著度更高(OR 1.76,95%CI 1.00-3.08,P=.04)。
诊断标准与关键数值
- 以BI-RADS 3为阈值,T+C模式 vs T模式敏感度82%(95%CI 74-89%) vs 81%(95%CI 74-88%),P=.68;特异度68%(95%CI 62-75%) vs 70%(95%CI 64-75%),P=.39。
- 以BI-RADS 4为阈值,T+C模式 vs T模式敏感度70%(95%CI 64-76%) vs 69%(95%CI 63-75%),P=.39;特异度91%(95%CI 87-96%) vs 91%(95%CI 88-95%),P=.90。
- 所有放射科医师平均AUC在T+C模式 vs T模式分别为0.84(95%CI 0.79-0.89) vs 0.83(95%CI 0.78-0.89),P=.61。
临床应用与阅片要点
- 在自动乳腺超声筛查阅片中增加冠状面可缩短阅片时间并提高乳腺癌病灶显著度。
- 增加冠状面未显著改善以BI-RADS 3或4为阈值的敏感度、特异度及平均AUC。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The coronal plane is the unique display mode of automated breast (AB) ultrasound (US), which has valuable features of showing the entire breast anatomy and providing additional diagnostic value for breast lesions. However, whether adding the coronal plane could improve the diagnostic performance in screening breast cancer remains uncertain. This study aimed to evaluate the value of adding the coronal plane in interpretation for AB US screening.
METHODS: In this retrospective study, AB US images from 644 women (396 in the no-finding group, 143 with benign lesions, and 105 with malignant lesions) aged 40-70 years were collected between January 2016 and October 2020. Four novice radiologists (with 1-5 years of experience with breast US) and four experienced radiologists (with >5 years of experience with breast US) were assigned to read all AB US images in the transverse plane plus coronal plane (T + C planes) and transverse plane (T plane) alone in separate reading sessions. Diagnostic performance, lesion conspicuity, and reading time were compared using analysis of variance.
RESULTS: The mean reading time of all radiologists was significantly shorter in the T + C planes reading mode than in the T plane alone (115 ± 32 vs 128 ± 31 s, respectively; P < .05), and cancers had a higher conspicuity (odds ratio, 1.76; 95% confidence interval [CI], 1.00-3.08; P = .04). No significant differences were noted in the two reading modes (T + C planes vs T plane) in the sensitivity (82% [95% CI, 74-89%] vs 81% [95% CI, 74-88%], respectively; P = .68) and specificity (68% [95% CI, 62-75%] vs 70% [95% CI, 64-75%], respectively; P = .39) when Breast Imaging-Reporting and Data System (BI-RADS) 3 was set as the threshold. There were also no significant differences in the two reading modes (T + C planes vs T plane) in the sensitivity (70% [95% CI, 64-76%] vs 69% [95% CI, 63-75%], respectively; P = .39) and specificity (91% [95% CI, 87-96%] vs 91% [95% CI, 88-95%], respectively; P = .90) when BI-RADS 4 was set as the threshold. In addition, the mean areas under the receiver operating characteristic curves of all radiologists in the two reading modes (T + C planes vs T plane) were not significantly different (0.84 [95% CI, 0.79-0.89] vs 0.83 [95% CI, 0.78-0.89], respectively; P = .61).
CONCLUSIONS: Adding a coronal plane in the AB US screening setting saved the reading time and improved the conspicuity of breast cancers but not the diagnostic performance.
引用
- Wang Y, Yue J, Xing Y, et al. Assessing Diagnostic Performance Using the Transverse Plane Plus Coronal Plane Compared With the Transverse Plane Alone in Screening Automated Breast Ultrasound. J Ultrasound Med. 2024. PMID: 38323467. doi:10.1002/jum.16428
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。