联合潜在应变弹性成像与影像组学诊断BI-RADS 4类乳腺病变:预测列线图的构建与验证
该研究回顾性纳入2017至2022年709例BI-RADS 4类乳腺病变患者,基于术前超声图像构建影像组学特征,联合B型超声、应变比和影像组学特征建立列线图,以组织学为金标准。训练集中列线图AUC为0.93,优于B型超声的0.84、应变比的0.78和影像组学特征的0.85(Delong检验均p<0.05),验证集用于评估其性能。
要点
- BI-RADS 4类病变中,列线图预测恶性的AUC=0.93,高于B型超声0.84、应变比0.78和影像组学特征0.85。
- 列线图整合了B型超声、应变比和影像组学特征,校准和判别性能良好。
- 研究为回顾性设计,训练集497例、验证集212例,组织学为金标准。
核心结论
- 校准后的列线图可专门用于预测BI-RADS 4类乳腺病变的恶性风险。
研究设计与样本
- 回顾性纳入2017至2022年709例连续BI-RADS 4类病变患者,训练集497例、验证集212例,以组织学为金标准。
诊断标准与关键数值
- 训练集中B型超声诊断BI-RADS 4类病变良恶性的AUC为0.84(95%CI 0.80-0.87)。
- 训练集中应变比诊断BI-RADS 4类病变良恶性的AUC为0.78(95%CI 0.74-0.82)。
- 训练集中影像组学特征诊断BI-RADS 4类病变良恶性的AUC为0.85(95%CI 0.81-0.88)。
- 训练集中列线图诊断BI-RADS 4类病变良恶性的AUC为0.93,优于B型超声、应变比和影像组学特征(Delong检验均p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To develop a nomogram by integrating B-mode ultrasound (US), strain ratio (SR), and radiomics signature (RS) effectively differentiating between benign and malignant lesions in the Breast Imaging Reporting and Data System (BI-RADS) 4.
MATERIALS AND METHODS: We retrospectively recruited 709 consecutive patients who were assigned a BI-RADS 4 and underwent curative resection or biopsy between 2017 and 2022. US images were collected before surgery. A RS was developed through a multistep feature selection and construction process. Histology findings served as the gold standard. Univariate and multivariate regression analysis were employed to analyze the clinical and US characteristics and identify variables for developing a nomogram. The calibration and discrimination of the nomogram were conducted to evaluate its performance.
RESULTS: The study included a total of 709 patients, with 497 in the training set and 212 in the validation set. In the training set, the B-mode US had an AUC of 0.84 (95% confidence interval [CI], 0.80, 0.87). The SR demonstrated an AUC of 0.78 (95% CI, 0.74, 0.82), while the RS showed an AUC of 0.85 (95% CI, 0.81, 0.88). Notably, the nomogram exhibited superior performance compared to the conventional US, SR, and RS (AUC=0.93, both p < 0.05, as per the Delong test). The clinical usefulness of the nomogram was favorable.
CONCLUSION: The calibrated nomogram can be specifically designed to predict the malignancy of breast lesions in the BI-RADS 4 category.