深度学习在基于视频的超声乳腺癌筛查中的诊断性能:一项回顾性多中心研究
该回顾性多中心研究纳入3907例22至86岁女性患者,构建基于DenseNet121、MobileNet和Xception的深度学习框架处理视频与图像超声数据,MobileNet视频模型在真实世界数据中准确率92.59%,超过DenseNet121和Xception视频模型及人类专家76.00%至85.60%的准确率范围。
要点
- MobileNet视频模型在真实世界数据测试中准确率92.59%,超过人类专家76.00%至85.60%的准确率范围。
- MobileNet视频模型在准确率、敏感度、特异度、F1分数和AUC所有评估指标上均超过图像模型和其他视频模型。
- 视频模型的专业水平高于基于图像的模型,该人工智能框架可能有助于乳腺癌诊断并缓解经验丰富的专家短缺。
核心结论
- 视频模型达到的专业水平高于基于图像的模型,所开发的人工智能框架可能有助于乳腺癌诊断并缓解经验丰富的专家短缺。
研究设计与样本
- 回顾性多中心研究,使用3907例患者数据训练和评估模型,框架以DenseNet121、MobileNet和Xception为骨干,分别构建视频和图像模型,并通过视频和图像方法及人类专家阅读研究进行测试。
诊断标准与关键数值
- MobileNet视频模型在前瞻性数据测试中AUROC为0.961,超过DenseNet121视频模型。
- MobileNet视频模型在真实世界数据测试中准确率92.59%,超过DenseNet121和Xception视频模型,并超过人类专家76.00%至85.60%的准确率范围。
- MobileNet视频模型在准确率、敏感度、特异度、F1分数和AUC所有评估指标上均超过图像模型和其他视频模型。
临床应用与阅片要点
- MobileNet视频模型表现优异,尤其适合资源有限的临床环境,展示其在乳腺癌筛查中临床应用的潜力。
- 视频模型达到的专业水平高于基于图像的模型,该人工智能框架可能有助于乳腺癌诊断并缓解经验丰富的专家短缺。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Although ultrasound is a common tool for breast cancer screening, its accuracy is often operator-dependent. In this study, we proposed a new automated deep-learning framework that extracts video-based ultrasound data for breast cancer screening.
METHODS: Our framework incorporates DenseNet121, MobileNet, and Xception as backbones for both video- and image-based models. We used data from 3907 patients to train and evaluate the models, which were tested using video- and image-based methods, as well as reader studies with human experts.
RESULTS: This study evaluated 3907 female patients aged 22 to 86 years. The results indicated that the MobileNet video model achieved an AUROC of 0.961 in prospective data testing, surpassing the DenseNet121 video model. In real-world data testing, it demonstrated an accuracy of 92.59%, outperforming both the DenseNet121 and Xception video models, and exceeding the 76.00% to 85.60% accuracy range of human experts. Additionally, the MobileNet video model exceeded the performance of image models and other video models across all evaluation metrics, including accuracy, sensitivity, specificity, F1 score, and AUC. Its exceptional performance, particularly suitable for resource-limited clinical settings, demonstrates its potential for clinical application in breast cancer screening.
CONCLUSIONS: The level of expertise reached by the video models was greater than that achieved by image-based models. We have developed an artificial intelligence framework based on videos that may be able to aid breast cancer diagnosis and alleviate the shortage of experienced experts.
引用
- Chen J, Huang Z, Jiang Y, et al. Diagnostic Performance of Deep Learning in Video-Based Ultrasonography for Breast Cancer: A Retrospective Multicentre Study. Ultrasound Med Biol. 2024. PMID: 38369431. doi:10.1016/j.ultrasmedbio.2024.01.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。