二维经会阴超声测量足月妊娠未产妇女肛提肌裂孔横径的新技术:可行性与可重复性研究

Feasibility and reproducibility of new technique for measurement of transverse diameter of levator ani muscle hiatus using two-dimensional transperineal ultrasound in nulliparous women with term pregnancy.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-01-01

在足月妊娠未产妇女中开发并描述冠状面二维经会阴超声测量肛提肌裂孔横径的技术,并评估其可行性与可重复性,以及与三维经会阴超声轴平面测量(金标准)的方法间一致性。

要点

  • 冠状面二维经会阴超声测量肛提肌裂孔横径在足月未产妇女中可行且可重复性高。
  • 二维测量与三维轴平面重建测量一致性几乎完美,组内相关系数0.85。
  • 测量平面位于尿道中心下方中位4 mm(范围0–9 mm)处。

核心结论

  • 利用本文描述的冠状面二维经会阴超声技术测量足月妊娠未产妇女肛提肌裂孔横径不仅可行,而且高度可重复且准确,其测量结果与三维经会阴超声重建轴平面所得测量结果相当。

研究设计与样本

  • 研究分两阶段:第一阶段纳入30例,采集三维经会阴超声容积并用多平面模式确定冠状面肛提肌外侧缘标志及测量平面与尿道中心距离;第二阶段纳入100例,每人采集三段冠状面二维视频剪辑和三维容积,二维视频上由一名操作者测量两次、另一名操作者测量一次,三维容积轴平面由一名操作者测量一次作为金标准,操作者相互盲法。

关键影像表现/征象

  • 冠状面肛提肌裂孔横径外侧缘标志表现为高回声肛提肌结构内侧缘处两个对称的低回声凹陷,位于肛提肌两侧距离最大处。
  • 三维经会阴超声轴平面测量横径的平面与尿道之间距离中位4 mm,范围0–9 mm。

诊断标准与关键数值

  • 观察者内可重复性组内相关系数0.95(95%CI 0.92–0.96),平均差异0.1 mm。
  • 观察者间可重复性组内相关系数0.87(95%CI 0.78–0.92),平均差异1.0 mm,观察者间分析存在系统性差异但临床不显著(38.2 mm vs 37.2 mm,P=0.01)。
  • 二维与三维方法间一致性组内相关系数0.85(95%CI 0.78–0.90),平均差异0.2 mm。
  • 母亲体重指数和母亲年龄对观察者内、观察者间及方法间信度均无统计学显著影响。

临床应用与阅片要点

  • 冠状面二维经会阴超声可作为测量足月未产妇女肛提肌裂孔横径的可行方法,测量结果与三维轴平面重建结果相当。
  • 测量时以高回声肛提肌结构内侧缘的两个对称低回声凹陷作为外侧缘标志,测量平面位于尿道中心下方中位4 mm处。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of the present study was two-fold. Firstly, we aimed to develop and describe a technique for measurement of the transverse diameter (TD) of the levator ani muscle (LAM) hiatus in the coronal view using two-dimensional (2D) transperineal ultrasound (TPUS) in nulliparous women with a term pregnancy. Secondly, we aimed to evaluate the feasibility and reproducibility of 2D-TPUS assessment of LAM hiatal TD and assess intermethod agreement between 2D-TPUS and three-dimensional (3D) TPUS measurement of TD in the axial plane, which is considered the gold standard in nulliparous women with term pregnancy.

METHODS: We recruited a group of nulliparous women with term pregnancy before the onset of labor. The study was conducted in two phases: Phase 1 involved developing and describing the 2D-TPUS technique for measuring LAM hiatal TD, and Phase 2 focused on assessing the technique's feasibility, reproducibility and intermethod agreement with 3D-TPUS measurement of LAM hiatal TD. In Phase 1, we enrolled 30 women. Each woman underwent acquisition of a 3D-TPUS volume, which was analyzed using multiplanar mode to identify and determine the appearance of the lateral borders of the LAM in the coronal plane, at the level of the plane of minimal hiatal dimensions. These borders were used as landmarks for TD measurement. Additionally, we measured the distance between the plane used for TD measurement and the center of the urethra in the axial view. In Phase 2, we recruited 100 women. Each woman underwent acquisition of three 2D-TPUS videoclips in the coronal plane, each encompassing a sweep of the entire LAM hiatus, and a 3D volume, all obtained during rest. On the 2D videoclips, TD was measured twice by one operator and once by another operator. In the 3D volume, TD was measured once, by one operator, in the axial plane; this measurement was considered the gold standard. Each operator was blinded to all other measurements during their assessments. We analyzed intraobserver and interobserver reproducibility and performed an intermethod (2D vs 3D) comparison. Bland-Altman analysis was conducted, and Levene's W0 test and Student's t-test were performed to explore clinical factors that might contribute to systematic differences.

RESULTS: In Phase 1, we identified successfully the landmarks denoting the lateral borders of the LAM hiatal TD in the coronal view. These appeared as two symmetrical hypoechogenic indentations located at the inner border of the hyperechogenic structure of the LAM, at the point of maximum distance between the two sides of the LAM. The distance between the urethra and the plane where TD should be measured using 3D-TPUS in the axial plane had a median of 4 mm and varied from 0 to 9 mm. This enabled us to describe a method for assessing LAM hiatal TD in the coronal plane using 2D-TPUS. In Phase 2, LAM hiatal TD was measured successfully in all 2D and 3D acquisitions from the entire group of 100 women. The analyses for intraobserver and interobserver reproducibility and the intermethod comparison (2D vs 3D) revealed almost perfect agreement in TD measurements using 2D-TPUS, with intraclass correlation coefficients of 0.95 (95% CI, 0.92-0.96), 0.87 (95% CI, 0.78-0.92) and 0.85 (95% CI, 0.78-0.90), respectively. The average differences between measurements were 0.1 mm for intraobserver, 1.0 mm for interobserver and 0.2 mm for intermethod repeatability. No systematic differences were observed in any of the measurement sets, except in the interobserver analysis, although this difference was clinically not significant (38.2 vs 37.2 mm, P = 0.01). None of the examined clinical factors (maternal body mass index and maternal age) exhibited a statistically significant impact on intraobserver, interobserver or intermethod reliability.

CONCLUSIONS: Utilizing our technique, described herein, to measure the LAM hiatal TD in the coronal view using 2D-TPUS is not only feasible but also highly reproducible and accurate in nulliparous women with term pregnancy. Moreover, it yields measurements that are comparable to those obtained in the reconstructed axial plane generated by 3D-TPUS. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Youssef A, Del Magno A, Nedu B, et al. Feasibility and reproducibility of new technique for measurement of transverse diameter of levator ani muscle hiatus using two-dimensional transperineal ultrasound in nulliparous women with term pregnancy. Ultrasound Obstet Gynecol. 2024. PMID: 38308852. doi:10.1002/uog.27595