文献速递妇产影像US

宫内节育器位置异常与既往剖宫产及子宫解剖学改变的相关性

Association of Intrauterine Device Malposition With Previous Cesarean Delivery and Related Uterine Anatomical Changes.
PubMed 文献 · J Ultrasound Med · 2024-02-29

回顾性队列纳入2年内因妇科指征行盆底二维及三维超声的296例宫内节育器使用者,其中56例(18.9%)位置异常,最常见位于子宫下段及宫颈(67.9%)。校正混杂因素后,既往剖宫产与位置异常显著相关(aOR 3.50,95%CI 1.31-9.35,P=.01);剖宫产者中子宫后屈及较大剖宫产瘢痕缺损为独立危险因素。

要点

  • 既往剖宫产者发生位置异常的风险约为无剖宫产者的3.50倍(aOR 3.50,95%CI 1.31-9.35)。
  • 剖宫产者中子宫后屈(aOR 4.1,95%CI 1.1-15.9)与较大剖宫产瘢痕缺损(aOR 5.4,95%CI 1.4-20.9)为独立危险因素。

核心结论

  • 既往剖宫产与宫内节育器位置异常风险显著增加相关;剖宫产者中子宫后屈及较大剖宫产瘢痕缺损者更易发生位置异常。

研究设计与样本

  • 回顾性队列研究,纳入2年内因任何妇科指征行盆底二维及三维超声的296例宫内节育器使用者。

关键影像表现/征象

  • 位置异常定义为宫内节育器部分或完全位于子宫内膜腔外。
  • 宫内节育器位置异常最常见位于子宫下段及宫颈,占67.9%。
  • 评估了子宫位置、子宫屈曲度及剖宫产瘢痕缺损大小。

诊断标准与关键数值

  • 宫内节育器位置异常:宫内节育器部分或完全位于子宫内膜腔外。
  • 既往剖宫产与位置异常关联:aOR 3.50,95%CI 1.31-9.35,P=.01。
  • 剖宫产者中子宫后屈:aOR 4.1,95%CI 1.1-15.9,P=.04。
  • 剖宫产者中较大剖宫产瘢痕缺损:aOR 5.4,95%CI 1.4-20.9,P=.01。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We sought to determine the association between intrauterine device (IUD) malposition and previous cesarean delivery (CD) and related uterine anatomical changes.

METHODS: A retrospective cohort of all persons with an IUD presenting for two- and three-dimensional pelvic ultrasonography over 2 years, for any gynecologic indication, was compiled. IUD malposition was defined as IUD partially or completely positioned outside the endometrial cavity. Uterine position, uterine flexion, and cesarean scar defect (CSD) size were assessed. Patient characteristics and sonographic findings were compared between those with normally positioned and malpositioned IUD. Primary outcome was the rate of IUD malposition in persons with and without a history of CD. Logistic regression analysis was used to control for potential confounders.

RESULTS: Two hundred ninety-six persons with an IUD had a pelvic ultrasound, 240 (81.1%) had a normally positioned IUD, and 56 (18.9%) had a malpositioned IUD. The most common location of IUD malposition was low uterine segment and cervix (67.9%). Malpositioned IUD was associated with referral for evaluation of pelvic pain (P = .001). Prior CD was significantly associated with a malpositioned IUD, after adjusting for confounders (aOR 3.50, 95% CI 1.31-9.35, P = .01). Among persons with prior CD, uterine retroflexion and a large CSD were independent risk factors for IUD malposition (aOR 4.1, 95% CI 1.1-15.9, P = .04 and aOR 5.4, 95% CI 1.4-20.9, P = .01, respectively).

CONCLUSIONS: Prior CD is associated with significantly increased risk of IUD malposition. Among persons with previous CD, those with a retroflexed uterus and a large CSD are more likely to have a malpositioned IUD.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Doulaveris G, Jou J, Leung WK, et al. Association of Intrauterine Device Malposition With Previous Cesarean Delivery and Related Uterine Anatomical Changes. J Ultrasound Med. 2024. PMID: 38421056. doi:10.1002/jum.16440

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。