金属股骨头假体在前列腺癌MR Linac成像中引起的几何畸变:空间变形的在体测量
在MR Linac上对5名观察者评估三种序列,通过骨性标志点坐标差异测量金属股骨头假体所致几何畸变,中位差异≤3 mm,组内相关系数0.70–0.83,提示畸变不构成骨盆放疗的障碍,但需进一步研究其对计划质量的影响。
要点
- 金属股骨头假体所致标志点位置中位差异≤3 mm(范围0.3–4.4 mm)。
- 观察者间组内相关系数平面内0.70、平面外0.78,观察者内0.76–0.83。
- 作者认为该畸变不构成MR Linac骨盆放疗的障碍,但需研究对计划质量的影响。
核心结论
- 这项在体可行性研究提示,金属髋关节假体所致畸变不构成MR Linac骨盆放疗的障碍,但需进一步研究其对计划质量的影响。
研究设计与样本
- 在体可行性研究,5名观察者参与,在MR Linac(Elekta Unity)上评估三种序列(两种厂商提供的T2W TSE 3D及一种优化以减少金属伪影畸变的T2W TSE 3D),由单一观察者基于骨性解剖将图像刚性配准至CT,选取3个冠状面和3个轴面图像,每层识别6对相邻骨性标志点,差异以标志点坐标差衡量。
诊断标准与关键数值
- 标志点位置中位差异≤3 mm(范围0.3–4.4 mm)。
- 单因素方差分析显示序列或患者间观察者均值无显著差异(平面内P=1.26,平面外P=0.11)。
- 观察者间组内相关系数平面内0.70、平面外0.78;3名观察者的观察者内组内相关系数分别为0.76、0.81、0.83。
临床应用与阅片要点
- 作者认为金属髋关节假体所致畸变不构成MR Linac骨盆放疗的障碍。
- 作者提出需进一步研究该畸变对计划质量的影响。
局限性
- 原文称该研究为小队列(small cohort)。
- 原文结论指出需进一步研究对计划质量的影响(Research on the impact on plan quality is warranted)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Metallic implants cause artefacts and distortion on MRI. To ensure accurate dose delivery and plan adaptation on an MR Linac, there is a need to evaluate distortion caused.
METHODS: Participants were imaged on an MR Linac (Elekta Unity, Elekta AB Stockholm). Three sequences were evaluated. Two vendor supplied (T2W TSE 3D), and one T2W TSE 3D optimized to reduce metal artefact distortions. Images were rigidly registered to CT images by a single observer, using bony anatomy. Three coronal and three axial images were selected, and six paired, adjacent, bony landmarks were identified on each slice. Images bisecting treatment isocentre were included. Difference between landmark coordinates was taken to be measure of distortion.
RESULTS: Five observers participated. Thirty six pairs of bony landmarks were identified. Median difference in position of landmarks was ≤3 mm (range 0.3-4.4 mm). One-way analysis of variance (ANOVA) between observer means showed no significant variation between sequences or patients (P = 1.26 in plane, P = 0.11 through plane). Interobserver intra class correlation (ICC) was 0.70 in-plane and 0.78 through-plane. Intra-observer ICC for three observers was 0.76, 0.81, 0.83, showing moderate to good reliability on this small cohort.
CONCLUSIONS: This in-vivo feasibility study suggests distortion due to metallic hip prosthesis is not an obstacle for pelvic radiotherapy on an MR Linac. Research on the impact on plan quality is warranted.
ADVANCES IN KNOWLEDGE: This work supports feasibility of treating patients with metallic hip prosthesis on an MR Linac.
引用
- McDaid L, Clough A, Benson RK, et al. Geometric distortion caused by metallic femoral head prosthesis in prostate cancer imaging on an MR Linac: in-vivo measurements of spatial deformation. Br J Radiol. 2024. PMID: 38407369. doi:10.1093/bjr/tqae044