文献速递儿科影像腹部US

高频探头对婴儿幽门肌厚度超声测量的影响

The impact of high-frequency transducers on the sonographic measurements of the pyloric muscle thickness in infants.
PubMed 文献 · Pediatr Radiol · 2024-02-29

回顾性分析2019年1月至2020年12月300例疑似肥厚性幽门狭窄婴儿的腹部超声,比较两种幽门肌厚度测量方法的诊断准确性:仅测量固有肌层的测量(b)准确率98.0%,高于包含黏膜肌层的测量(a)的89.7%;幽门壁分层消失和固有肌层回声增强仅见于肥厚性幽门狭窄。

要点

  • 仅测量固有肌层的测量(b)诊断准确率98.0%,优于测量(a)的89.7%。
  • 测量(b)中位厚度正常1.4 mm、肥厚性幽门狭窄4.0 mm;测量(a)为2.4 mm和4.8 mm。
  • 幽门壁分层消失仅见于肥厚性幽门狭窄(28/59,47.5%),正常例均保留分层。

核心结论

  • 仅测量固有肌层具有更好的诊断准确性,可减少阴性与阳性病例的重叠;幽门壁分层消失和固有肌层回声增强仅见于肥厚性幽门狭窄。

研究设计与样本

  • 回顾性分析2019年1月至2020年12月疑似肥厚性幽门狭窄婴儿的腹部超声,共300例(女114例,男186例),其中肥厚性幽门狭窄59例、正常241例;由两名儿科放射科医生独立测量,前100例评估读者间一致性。

关键影像表现/征象

  • 所有正常例均保留幽门分层,肥厚性幽门狭窄中31/59(52.5%)保留分层。
  • 肥厚性幽门狭窄中28/59(47.5%)出现幽门壁分层完全或部分消失。
  • 所有肥厚性幽门狭窄病例的固有肌层均呈回声增强。

诊断标准与关键数值

  • 测量(a)纳入固有肌层和黏膜肌层:正常中位厚度2.4 mm,肥厚性幽门狭窄4.8 mm;准确率89.7%(95%CI 85.7-92.8%),敏感度98.3%,特异度87.6%。
  • 测量(b)仅纳入固有肌层:正常中位厚度1.4 mm,肥厚性幽门狭窄4.0 mm;准确率98.0%(95%CI 95.7-99.3%),敏感度89.8%,特异度100.0%。
  • 前100例读者间一致性ICC为0.99(95%CI 0.98-0.99)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Ultrasound is the modality of choice for the diagnosis of hypertrophic pyloric stenosis (HPS). The evolution of high-frequency transducers in ultrasound has led to inconsistent ways of measuring the pylorus.

OBJECTIVE: To standardize the measurements and evaluate the appearance of the normal and hypertrophied pylorus with high-frequency transducers.

MATERIALS AND METHODS: We retrospectively analyzed abdominal ultrasounds of infants with suspected HPS from January 2019-December 2020. We classified the layers of the pylorus while assessing the stratified appearance. Two pediatric radiologists measured the muscle thickness of the pylorus independently by two methods for interrater agreement. Measurement (a) includes the muscularis propria and muscularis mucosa. Measurement (b) includes only the muscularis propria. We also evaluated the echogenicity of the muscularis propria. The interrater agreement, mean, range of the muscle thickness, and the diagnostic accuracy of the two sets of measurements were calculated.

RESULTS: We included 300 infants (114 F:186 M), 59 with HPS and 241 normal cases. There was a strong agreement between the readers assessed in the first 100 cases, and ICC was 0.99 (95% CI, 0.98-0.99). Measurement (a), median thickness is 2.4 mm in normal cases and 4.8 mm in HPS. Measurement (b), median thickness is 1.4 mm in normal cases and 4.0 mm in HPS. Measurement (a) has an accuracy of 89.7% (95% CI, 85.7-92.8%) with 98.3% sensitivity and 87.6% specificity. Measurement (b) has an accuracy of 98.0% (95% CI, 95.7-99.3%) with 89.8% sensitivity and 100.0% specificity. The pylorus stratification is preserved in all normal cases and 31/59 (52.5%) cases of HPS. There was complete/partial loss of stratification in 28/59 (47.5%) cases of HPS. In all HPS cases, the muscularis propria was echogenic.

CONCLUSION: Measuring the muscularis propria solely has a better diagnostic accuracy, decreasing the overlap of negative and positive cases. The loss of pyloric wall stratification and echogenic muscularis propria is only seen in HPS.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Yousef A, Daneman A, Amirabadi A, et al. The impact of high-frequency transducers on the sonographic measurements of the pyloric muscle thickness in infants. Pediatr Radiol. 2024. PMID: 38418631. doi:10.1007/s00247-024-05881-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。