文献速递腹部CT

双层光谱探测器CT:术前无创预测胰腺导管腺癌组织病理学分级的工具

Dual-layer spectral detector CT: A noninvasive preoperative tool for predicting histopathological differentiation in pancreatic ductal adenocarcinoma.
PubMed 文献 · Eur J Radiol · 2024-01-24

回顾性纳入128例经病理证实且术前行双层光谱探测器CT的胰腺导管腺癌患者,分为低级别组82例和高级别组46例。坏死_con、坏死_40keV和IEF_AP/VP为独立预测因子,联合模型敏感度72%、准确率79%,IEF_AP/VP特异度89%。双层光谱探测器CT变量有术前评估肿瘤分级的潜力,光谱变量及其联合优于常规CT变量。

要点

  • 静脉期与动脉期碘浓度比值IEF_AP/VP是独立预测因子,AUC 0.754,特异度89%。
  • 40keV虚拟单能图像评估坏死_40keV为光谱独立预测因子,OR 5.82。
  • 光谱变量联合模型AUC 0.812,敏感度72%、准确率79%,优于常规CT坏死征象。

核心结论

  • 双层光谱探测器CT衍生变量有术前评估胰腺导管腺癌肿瘤分级的潜力,光谱变量及其联合模型预测性能优于常规CT变量。

研究设计与样本

  • 回顾性纳入128例经组织病理学证实且术前行双层光谱探测器CT的胰腺导管腺癌患者,分为低级别组(高分化与中分化,n=82)和高级别组(低分化,n=46)。

关键影像表现/征象

  • 常规CT图像评估的坏死_con为常规变量中的独立预测因子,OR 2.84(95%CI 1.13-7.13;p<0.001)。
  • 40keV虚拟单能图像评估的坏死_40keV为光谱变量中的独立预测因子,OR 5.82(95%CI 1.98-17.11;p=0.001)。
  • 动脉期与静脉期碘浓度比值IEF_AP/VP为光谱变量中的独立预测因子,OR 1.12(95%CI 1.07-1.17;p<0.001)。

诊断标准与关键数值

  • IEF_AP/VP预测低级别与高级别胰腺导管腺癌的AUC为0.754(p=0.016),特异度89%。
  • 联合模型预测低级别与高级别胰腺导管腺癌的AUC为0.812(p<0.001),敏感度72%、准确率79%。
  • 坏死_con预测低级别与高级别胰腺导管腺癌的AUC为0.580。

临床应用与阅片要点

  • 术前可测量动脉期与静脉期碘浓度并计算IEF_AP/VP,用于辅助区分低级别与高级别胰腺导管腺癌。
  • 可在40keV虚拟单能图像上评估坏死_40keV,并与IEF_AP/VP联合用于术前分级预测。
  • 光谱变量及联合模型预测性能优于常规CT坏死_con,阅片时可结合光谱参数综合判断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To predict histopathological differentiation grades in patients with pancreatic ductal adenocarcinoma (PDAC) before surgery with quantitative and qualitative variables obtained from dual-layer spectral detector CT (DLCT).

METHODS: Totally 128 patients with histopathologically confirmed PDAC and preoperative DLCT were retrospectively enrolled and categorized into the low-grade (LG) (well and moderately differentiated, n = 82) and high-grade (HG) (poorly differentiated, n = 46) subgroups. Both conventional and spectral variables for PDAC were measured. The ratio of iodine concentration (IC) values in arterial phase(AP) and venous phase (VP) was defined as iodine enhancement fraction_AP/VP (IEF_AP/VP). Necrosis was visually assessed on both conventional CT images (necrosis_con) and virtual mono-energetic images (VMIs) at 40 keV (necrosis_40keV). Forward stepwise logistic regression method was conducted to perform univariable and multivariable analysis. Receiver operating characteristic (ROC) curves and the DeLong method were used to evaluate and compare the efficiencies of variables in predicting tumor grade.

RESULTS: Necrosis_con (odds ratio [OR] = 2.84, 95% confidence interval [CI]: 1.13-7.13; p < 0.001) was an independent predictor among conventional variables, and necrosis_40keV (OR = 5.82, 95% CI: 1.98-17.11; p = 0.001) and IEF_AP/VP (OR = 1.12, 95% CI:1.07-1.17; p < 0.001) were independent predictors among spectral variables for distinguishing LG PDAC from HG PDAC. IEF_AP/VP (AUC = 0.754, p = 0.016) and combination model (AUC = 0.812, p < 0.001) had better predictive performances than necrosis_con (AUC = 0.580). The combination model yielded the highest sensitivity (72%) and accuracy (79%), while IEF_AP/VP exhibited the highest specificity (89%).

CONCLUSION: Variables derived from DLCT have the potential to preoperatively evaluate PDAC tumor grade. Furthermore, spectral variables and their combination exhibited superior predictive performances than conventional CT variables.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Liu W, Xie T, Chen L, et al. Dual-layer spectral detector CT: A noninvasive preoperative tool for predicting histopathological differentiation in pancreatic ductal adenocarcinoma. Eur J Radiol. 2024. PMID: 38330535. doi:10.1016/j.ejrad.2024.111327

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。