结直肠癌肝转移的多序列MRI影像组学:哪些特征在不同阅片者之间具有可重复性
研究在23例患者30个结直肠癌肝转移灶上,由3名阅片者于化疗前在CE-T1W、T2W和b800 DWI上手动勾画(DWI勾画复制至ADC图),每序列提取107个影像组学特征并以ICC>0.9判定可重复。CE-T1W、DWI、T2W和ADC分别有90%、81%、80%和58%的特征可重复;CE-T1W略优于DWI和T2W,ADC特征似乎更易受阅片者差异影响。
要点
- CE-T1W可重复特征比例最高(90%),中位ICC 0.98,ADC最低(58%),中位ICC 0.91。
- 以ICC 95%CI下限≥0.9计,CE-T1W、DWI、T2W、ADC分别仅58%、66%、54%、29%达标。
- 最佳可重复的特征类别因序列而异,ADC特征似乎更易受阅片者差异影响。
核心结论
- 结直肠癌肝转移CE-T1W、T2W、DWI和ADC的多数MRI影像组学特征对阅片者间勾画变异具有稳健性,CE-T1W的可重复性略优于DWI和T2W,ADC特征似乎更易受阅片者差异影响。
研究设计与样本
- 研究论文;23例患者共30个结直肠癌肝转移灶,化疗开始前由3名阅片者在CE-T1W门静脉期、T2W和b800 DWI上手动勾画,DWI勾画复制至ADC图,每序列提取107个影像组学特征,以ICC>0.9判定可重复。
诊断标准与关键数值
- 可重复判定标准为ICC>0.9;CE-T1W可重复特征占90%,中位ICC 0.98(范围0.76-1.00);DWI占81%,中位ICC 0.97(范围0.38-1.00);T2W占80%,中位ICC 0.96(范围0.55-0.99);ADC占58%,中位ICC 0.91(范围0.38-0.99)。
临床应用与阅片要点
- CE-T1W可重复特征比例90%高于DWI的81%和T2W的80%,ADC最低为58%。
- 以ICC 95%CI下限≥0.9计,CE-T1W、DWI、T2W、ADC分别有58%、66%、54%、29%的特征达标。
- 最佳可重复的特征类别因序列而异,ADC特征似乎更易受阅片者差异影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the inter-reader reproducibility of radiomics features on multiple MRI sequences after segmentations of colorectal liver metastases (CRLM).
METHOD: 30 CRLM (in 23 patients) were manually delineated by three readers on MRI before the start of chemotherapy on the contrast enhanced T1-weighted images (CE-T1W) in the portal venous phase, T2-weighted images (T2W) and b800 diffusion weighted images (DWI). DWI delineations were copied to the ADC-maps. 107 radiomics features were extracted per sequence. The intraclass correlation coefficient (ICC) was calculated per feature. Features were considered reproducible if ICC > 0.9.
RESULTS: 90% of CE-T1W features were reproducible with a median ICC of 0.98 (range 0.76-1.00). 81% of DWI features were robust with median ICC = 0.97 (range 0.38-1.00). The T2W features had a median ICC of 0.96 (range 0.55-0.99) and were reproducible in 80%. ADC showed the lowest number of reproducible features with 58% and median ICC = 0.91 (range 0.38-0.99) When considering the lower bound of the ICC 95% confidence intervals, 58%, 66%, 54% and 29% reached 0.9 for the CE-T1W, DWI, T2W and ADC features, respectively. The feature class with the best reproducibility differed per sequence.
CONCLUSIONS: The majority of MRI radiomics features from CE-T1W, T2W, DWI and ADC in colorectal liver metastases were robust for segmentation variability between readers. The CE-T1W yielded slightly better reproducibility results compared to DWI and T2W. The ADC features seem more susceptible to reader differences compared to the other three sequences.
引用
- van der Reijd DJ, Chupetlovska K, van Dijk E, et al. Multi-sequence MRI radiomics of colorectal liver metastases: Which features are reproducible across readers? Eur J Radiol. 2024. PMID: 38309217. doi:10.1016/j.ejrad.2024.111346
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。