文献速递腹部技术与安全CT

基于瘤内及瘤周CT影像组学预测胃癌微卫星不稳定状态

Intratumoral and peritumoral CT-based radiomics for predicting the microsatellite instability in gastric cancer.
PubMed 文献 · Abdom Radiol (NY) · 2024-02-02

回顾189例胃癌患者(MSI-H 63例,MSI-L/S 126例),从增强CT提取瘤内及5mm瘤周影像组学特征构建模型。联合模型在验证队列中预测MSI状态的AUC最高,为0.830(95%CI 0.727-0.906),校准曲线和决策曲线显示良好的模型拟合度和临床应用价值。

要点

  • 联合瘤内及瘤周影像组学与临床因素(肿瘤长度、位置)的模型预测MSI状态AUC为0.830。
  • 瘤内及5mm瘤周区域共筛选出11个影像组学特征用于建模。
  • CT测量的肿瘤长度和肿瘤位置是MSI状态的独立危险因素。

核心结论

  • 基于瘤内及瘤周增强CT影像组学特征联合临床因素的联合模型可在术前以中等准确度预测胃癌MSI状态,有助于制定个性化治疗策略。

研究设计与样本

  • 回顾性研究,纳入189例胃癌患者(MSI-H 63例,MSI-L/S 126例),随机分为训练队列和验证队列,从增强CT图像提取瘤内及5mm瘤周区域影像组学特征,以病理MSI状态为参考标准。

诊断标准与关键数值

  • 联合模型在验证队列中预测MSI状态的AUC为0.830(95%CI 0.727-0.906)。
  • 基于瘤内+5mm瘤周区域筛选出11个影像组学特征建立影像组学模型。
  • CT测量的肿瘤长度和肿瘤位置为MSI状态的独立危险因素。

临床应用与阅片要点

  • 可基于增强CT提取瘤内及瘤周5mm区域影像组学特征,结合肿瘤长度和位置,术前评估胃癌MSI状态。
  • 联合模型在验证队列中校准曲线和决策曲线显示良好的模型拟合度和临床应用价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the value of intratumoral and peritumoral radiomics based on contrast-enhanced computer tomography (CECT) to preoperatively predict microsatellite instability (MSI) status in gastric cancer (GC) patients.

METHODS: A total of 189 GC patients, including 63 patients with MSI-high (MSI-H) and 126 patients with MSI-low/stable (MSI-L/S), were randomly divided into the training cohort and validation cohort. Intratumoral and 5-mm peritumoral regions' radiomics features were extracted from CECT images. The features were standardized by Z-score, and the Inter- and intraclass correlation coefficient, univariate logistic regression analysis, and least absolute shrinkage and selection operator (LASSO) were applied to select the optimal radiomics features. Radiomics scores (Rad-score) based on intratumoral regions, peritumoral regions, and intratumoral + 5-mm peritumoral regions were calculated by weighting the linear combination of the selected features with their respective coefficients to construct the intratumoral model, peritumoral model, and intratumoral + peritumoral model. Logistic regression was used to establish a combined model by combining clinical characteristics, CT semantic features, and Rad-score of intratumoral and peritumoral regions.

RESULTS: Eleven radiomics features were selected to establish a radiomics intratumoral + peritumoral model. CT-measured tumor length and tumor location were independent risk factors for MSI status. The established combined model obtained the highest area under the receiver operating characteristic (ROC) curve (AUC) of 0.830 (95% CI, 0.727-0.906) in the validation cohort. The calibration curve and decision curve demonstrated its good model fitness and clinical application value.

CONCLUSION: The combined model based on intratumoral and peritumoral CECT radiomics features and clinical factors can predict the MSI status of GS with moderate accuracy before surgery, which helps formulate personalized treatment strategies.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Chen X, Zhuang Z, Pen L, et al. Intratumoral and peritumoral CT-based radiomics for predicting the microsatellite instability in gastric cancer. Abdom Radiol (NY). 2024. PMID: 38305796. doi:10.1007/s00261-023-04165-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。