基于机器学习的CT血流储备分数与心脏MR灌注成像对稳定性冠心病缺血诊断的比较
研究前瞻性纳入110例稳定性冠心病患者,在2周内完成冠状动脉CTA、心脏MR及有创FFR检查,比较机器学习CT-FFR与心脏MR灌注定量指标MBF、MPR对有血流动力学意义狭窄的诊断效能。血管水平上MPR与CT-FFR的AUC分别为0.90和0.89(P=0.71),诊断效能相当;患者水平上MPR的AUC为0.96,优于CT-FFR的0.86(P=0.03)。
要点
- 血管水平:MPR的AUC 0.90与ML-based CT-FFR的AUC 0.89诊断效能相当(P=0.71)。
- 患者水平:MPR的AUC 0.96优于ML-based CT-FFR的AUC 0.86(P=0.03)。
- 定量灌注指标中,MPR识别有血流动力学意义狭窄的AUC最大(0.90)。
核心结论
- ML-based CT-FFR与心脏MR定量灌注在检测血管特异性有血流动力学意义狭窄方面诊断效能相当,而定量灌注成像在患者水平分析中表现更优。
研究设计与样本
- 前瞻性研究,2020年10月至2022年3月连续纳入110例稳定性冠心病患者(平均年龄62岁±8,73例男性),均完成冠状动脉CTA、心脏MR及有创FFR检查,检查间隔在2周内。
诊断标准与关键数值
- 有血流动力学意义狭窄定义为有创FFR≤0.8或侵入性冠状动脉造影(ICA)显示狭窄>90%;以有创FFR为参考标准。
临床应用与阅片要点
- 血管水平:MPR的AUC 0.90 vs ML-based CT-FFR的AUC 0.89(P=0.71),敏感度89% vs 79%(P=0.20),特异度87% vs 84%(P=0.48),准确率88% vs 83%(P=0.24)。患者水平:MPR的AUC 0.96 vs ML-based CT-FFR的AUC 0.86(P=0.03),特异度95% vs 82%(P=0.01),准确率95% vs 81%(P<0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the diagnostic performance of machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and cardiac magnetic resonance (MR) perfusion mapping for functional assessment of coronary stenosis.
METHODS: Between October 2020 and March 2022, consecutive participants with stable coronary artery disease (CAD) were prospectively enrolled and underwent coronary CTA, cardiac MR, and invasive fractional flow reserve (FFR) within 2 weeks. Cardiac MR perfusion analysis was quantified by stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Hemodynamically significant stenosis was defined as FFR ≤ 0.8 or > 90% stenosis on invasive coronary angiography (ICA). The diagnostic performance of CT-FFR, MBF, and MPR was compared, using invasive FFR as a reference.
RESULTS: The study protocol was completed in 110 participants (mean age, 62 years ± 8; 73 men), and hemodynamically significant stenosis was detected in 36 (33%). Among the quantitative perfusion indices, MPR had the largest area under receiver operating characteristic curve (AUC) (0.90) for identifying hemodynamically significant stenosis, which is in comparison with ML-based CT-FFR on the vessel level (AUC 0.89, p = 0.71), with comparable sensitivity (89% vs 79%, p = 0.20), specificity (87% vs 84%, p = 0.48), and accuracy (88% vs 83%, p = 0.24). However, MPR outperformed ML-based CT-FFR on the patient level (AUC 0.96 vs 0.86, p = 0.03), with improved specificity (95% vs 82%, p = 0.01) and accuracy (95% vs 81%, p < 0.01).
CONCLUSION: ML-based CT-FFR and quantitative cardiac MR showed comparable diagnostic performance in detecting vessel-specific hemodynamically significant stenosis, whereas quantitative perfusion mapping had a favorable performance in per-patient analysis.
CLINICAL RELEVANCE STATEMENT: ML-based CT-FFR and MPR derived from cardiac MR performed well in diagnosing vessel-specific hemodynamically significant stenosis, both of which showed no statistical discrepancy with each other.
KEY POINTS: • Both machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and quantitative perfusion cardiac MR performed well in the detection of hemodynamically significant stenosis. • Compared with stress myocardial blood flow (MBF) from quantitative perfusion cardiac MR, myocardial perfusion reserve (MPR) provided higher diagnostic performance for detecting hemodynamically significant coronary artery stenosis. • ML-based CT-FFR and MPR from quantitative cardiac MR perfusion yielded similar diagnostic performance in assessing vessel-specific hemodynamically significant stenosis, whereas MPR had a favorable performance in per-patient analysis.
引用
- Guo W, Zhao S, Xu H, et al. Comparison of machine learning-based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease. Eur Radiol. 2024. PMID: 38409549. doi:10.1007/s00330-024-10650-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。