子痫前期/子痫可能通过减少心肌致密化影响新生儿心脏结构与功能
本研究对2594名新生儿行超声心动图筛查,其中556名纳入影像组学分析,采用多块稀疏偏最小二乘法模型整合心脏形状、运动和纹理特征。子痫前期/子痫组新生儿左心室射血分数低于对照组(61.1% vs. 66.2%),代表心肌非致密化的纹理特征与子痫前期/子痫相关性最强(r=0.63),提示子痫前期/子痫可能导致更明显的心肌非致密化。
要点
- 子痫前期/子痫组新生儿左心室射血分数低于对照组(61.1% vs. 66.2%)。
- 心肌非致密化纹理特征与子痫前期/子痫相关性最强(r=0.63)。
- 子痫前期/子痫可能表现为非致密化层增厚和心脏小梁化增多。
核心结论
- 超声心动图影像组学可用于评估子痫前期/子痫对新生儿心脏功能的影响;子痫前期/子痫与心肌非致密化的相关性提示需对子痫前期/子痫母亲所生新生儿加强心脏监测。
研究设计与样本
- 研究纳入2594名接受超声心动图筛查的新生儿,其中556名纳入详细影像组学分析,采用多块稀疏偏最小二乘法模型整合心脏形状、运动和纹理特征。
关键影像表现/征象
- 子痫前期/子痫组新生儿左心室射血分数低于对照组(61.1% vs. 66.2%)。
- 纹理特征可视化提示子痫前期/子痫可能导致更明显的心肌非致密化,表现为非致密化层增厚和心脏小梁化增多。
诊断标准与关键数值
- 每名新生儿提取15494个影像组学特征,多块稀疏偏最小二乘法模型识别出17个与子痫前期/子痫显著相关的特征。
- 代表心肌非致密化的纹理特征与子痫前期/子痫相关性最强(相关系数r=0.63)。
临床应用与阅片要点
- 对子痫前期/子痫母亲所生新生儿进行超声心动图检查时,可关注心肌非致密化相关纹理特征及左心室射血分数。
- 影像组学方法可能有助于更全面地评估子痫前期/子痫对新生儿心脏结构和功能的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Preeclampsia/Eclampsia (PE/E) poses significant risks to neonatal cardiac health. Traditional echocardiographic methods have limitations in detailing these impacts. This study hypothesized that echocardiographic radiomics could provide a more comprehensive assessment of the cardiac changes in neonates affected by PE/E.
METHOD: In a comprehensive analysis, 2594 neonates underwent echocardiographic screening. From these, 556 were selected for detailed radiomics analysis, focusing on cardiac shape, movement, and texture features. A multiblock sparse partial least squares (sPLS) model integrated these features to assess their association with PE/E.
RESULTS: Newborns from PE/E-affected pregnancies displayed lower left ventricular ejection fractions compared to the control group (61.1 % vs. 66.2 %). Our radiomics approach extracted 15,494 features per neonate, with the sPLS model identifying 17 features significantly correlated with PE/E. Among these, texture features representing myocardial non-compaction were most strongly correlated with PE/E (correlation coefficient r = 0.63). Detailed visualization of these texture features suggested that PE/E might lead to more pronounced myocardial non-compaction, characterized by a thicker non-compaction layer and increased cardiac trabeculation.
CONCLUSIONS: Our findings demonstrate the potential of echocardiographic radiomics as a tool for assessing the impact of PE/E on neonatal cardiac function. The correlation between PE/E and myocardial non-compaction underlines the need for enhanced cardiac monitoring in neonates born to PE/E-affected mothers. This study contributes to a better understanding of PE/E's cardiac implications, potentially guiding future clinical practices.
引用
- Li Z, Zhu J, Chen Y, et al. Preeclampsia/eclampsia impacts the structure and function of neonatal hearts probably by reducing myocardial compaction. Eur J Radiol. 2024. PMID: 38382423. doi:10.1016/j.ejrad.2024.111382
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。