比较CT衍生血流储备分数与冠状动脉CT血管成像在不同冠状动脉钙化积分水平下诊断性能的Meta分析
本Meta分析纳入10项研究,以有创血流储备分数为参考标准,比较CT-FFR与CCTA在四个冠状动脉钙化积分组中基于患者和基于血管的诊断性能。除CACS≥400组外,CT-FFR在其他CACS亚组的AUC均高于CCTA。作者结论认为CT-FFR在低CACS组(CACS<400)检测血流动力学狭窄的诊断性能优于CCTA。
要点
- CACS<100组基于患者AUC:CT-FFR 0.9 vs CCTA 0.32,CT-FFR更高。
- CACS<400组基于血管AUC:CT-FFR 0.8 vs CCTA 0.74,CT-FFR更高(p=0.02)。
- CACS≥400组CT-FFR的AUC未高于CCTA,原文未报告该组具体数值。
核心结论
- CT-FFR在低CACS组(CACS<400)检测冠状动脉疾病患者血流动力学狭窄的诊断性能优于CCTA。
研究设计与样本
- Meta分析,检索PubMed、Embase和Cochrane Library,纳入10项关于CCTA、CT-FFR与有创FFR的研究,以有创FFR为参考标准,在四个CACS组中评估基于患者和基于血管的诊断性能。
诊断标准与关键数值
- CACS<100组基于患者AUC:CT-FFR 0.9(95%CI 0.87-0.92)vs CCTA 0.32(95%CI 0.28-0.36),p<0.001。
- CACS<100组基于血管AUC:CT-FFR 0.92(95%CI 0.89-0.94)vs CCTA 0.66(95%CI 0.62-0.7),p<0.001。
- CACS≥100组基于患者AUC:CT-FFR 0.86(95%CI 0.82-0.88)vs CCTA 0.44(95%CI 0.4-0.48),p<0.001;基于血管AUC:CT-FFR 0.88(95%CI 0.85-0.9)vs CCTA 0.51(95%CI 0.46-0.55),p<0.001。
- CACS<400组基于患者AUC:CT-FFR 0.9(95%CI 0.87-0.93)vs CCTA 0.74(95%CI 0.7-0.78),p<0.001;基于血管AUC:CT-FFR 0.8(95%CI 0.76-0.83)vs CCTA 0.74(95%CI 0.7-0.78),p=0.02。
- CACS≥400组:原文仅述CT-FFR的AUC未高于CCTA,未报告具体数值。
临床应用与阅片要点
- 作者认为,对于CACS<400的冠状动脉疾病患者,CT-FFR或可用于判断有创冠状动脉造影的必要性。
- 对于低冠状动脉钙化积分组,CT-FFR可能是检测冠状动脉疾病患者血流动力学狭窄的良好无创方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The impact of coronary calcification on the diagnostic accuracy of computed tomography-derived fractional flow reserve (CT-FFR) and coronary computed tomography angiography (CCTA) remains a crucial consideration. This meta-analysis aims to compare the diagnostic performance of CT-FFR and CCTA at different levels of coronary artery calcium score (CACS).
METHODS AND RESULTS: We searched PubMed, Embase, and the Cochrane Library for relevant articles on CCTA, CT-FFR, and invasive fractional flow reserve (FFR). Ten studies were included to evaluate the diagnostic performance of CT-FFR and CCTA at the per-patient and per-vessel levels in four CACS groups. Invasive FFR was used as the reference standard. Except for the CACS ≥ 400 group, the AUC of CT-FFR was higher than those of CCTA in other subgroups of CACS (in CACS < 100 (per-patient, 0.9 (95% CI 0.87-0.92) vs. 0.32 (95% CI 0.28-0.36); per-vessel, 0.92 (95% CI 0.89-0.94) vs. 0.66 (95% CI 0.62-0.7); both p < 0.001), CACS ≥ 100 (per-patient, 0.86 (95% CI 0.82-0.88) vs. 0.44 (95% CI 0.4-0.48); per-vessel, 0.88 (95% CI 0.85-0.9) vs. 0.51 (95% CI 0.46-0.55); both p < 0.001), and CACS < 400 (per-patient, 0.9 (95% CI 0.87-0.93) vs. 0.74 (95% CI 0.7-0.78), p < 0.001; per-vessel, 0.8 (95% CI 0.76-0.83) vs. 0.74 (95% CI 0.7-0.78); p = 0.02)).
CONCLUSIONS: CT-FFR demonstrates superior diagnostic performance in low CACS groups (CACS < 400) than CCTA in detecting hemodynamic stenoses in patients with coronary artery disease (CAD).
CLINICAL RELEVANCE STATEMENT: Computed tomography-derived fractional flow reserve might be utilized to determine the necessity of invasive coronary angiography in coronary artery disease patients with coronary artery calcium score < 400.
KEY POINTS: • There is a lack of meta-analysis comparing the diagnostic performance of computed tomography-derived fractional flow reserve and coronary computed tomography angiography at different levels of calcification. • Computed tomography-derived fractional flow reserve only has a better diagnostic performance than coronary computed tomography angiography with low amounts of coronary calcium. • For the low coronary artery calcium score group, computed tomography-derived fractional flow reserve might be a good non-invasive method to detect hemodynamic stenoses in coronary artery disease patients.
引用
- Ma Z, Tu C, Zhang B, et al. A meta-analysis comparing the diagnostic performance of computed tomography-derived fractional flow reserve and coronary computed tomography angiography at different levels of coronary artery calcium score. Eur Radiol. 2024. PMID: 38334761. doi:10.1007/s00330-024-10591-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。