8~15 mm实性肺癌中18F-氟脱氧葡萄糖PET低摄取病灶的CT特征分析
研究纳入235例8~15 mm无磨玻璃成分的实性肺癌患者,分析CT征象与18F-FDG PET的SUVmax关系。伴有空气支气管征和凹陷形状的病灶SUVmax显著更低,而合并肺气肿背景的病灶SUVmax更高;胸膜附着与否无显著差异。作者认为18F-FDG PET在鉴别某些类型小实性肺癌时可能造成误导。
要点
- 8~15 mm实性肺癌伴空气支气管征或凹陷形状时,18F-FDG摄取常偏低,PET可能假阴性。
- 合并肺气肿背景的小实性肺癌SUVmax反而更高,阅片时需结合背景肺条件判读。
- 空气支气管征与背景肺气肿的观察者间一致性几乎完美(κ=0.882和0.927)。
核心结论
- 在8~15 mm实性肺癌中,空气支气管征、凹陷形状及无肺气肿背景与18F-FDG低蓄积相关;18F-FDG PET在鉴别某些类型小实性肺癌时可能造成误导。
研究设计与样本
- 研究纳入2014年1月至2019年12月接受手术、术前CT示8~15 mm无磨玻璃成分实性结节且切除术前行18F-FDG PET的肺癌患者,共235例;由两名委员会认证放射科医师评估空气支气管征、凹陷形状、胸膜附着及背景肺气肿等CT征象。
关键影像表现/征象
- 有空气支气管征病灶SUVmax中位数1.55,无空气支气管征病灶2.56,前者显著更低(P < .001)。
- 有凹陷形状病灶SUVmax中位数1.66,无凹陷形状病灶2.45,前者显著更低(P < .001)。
- 起源于肺气肿肺的病灶SUVmax中位数2.90,起源于非肺气肿肺的病灶1.69,前者显著更高(P < .001)。
- 胸膜附着与未附着病灶间SUVmax无显著差异。
- 有空气支气管征且起源于非肺气肿肺的病灶中,89.7%的SUVmax低于2.5。
诊断标准与关键数值
- 空气支气管征观察者间一致性κ=0.882,背景肺气肿观察者间一致性κ=0.927。
- 有空气支气管征且起源于非肺气肿肺的病灶中,89.7%的SUVmax低于2.5。
临床应用与阅片要点
- 阅片时注意8~15 mm实性肺癌若伴空气支气管征或凹陷形状,18F-FDG PET可能显示低摄取,不应据此排除恶性。
- 判读小实性肺癌PET时应结合背景肺气肿情况,肺气肿背景病灶SUVmax可能更高。
- 胸膜附着与否对SUVmax无显著影响,不应作为判断FDG摄取的依据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine the image characteristics associated with low 18F-FDG (18F-fluorodeoxyglucose) avidity among 8-15 mm solid lung cancer.
METHODS: Patients satisfying the following criteria were included: underwent surgery between January 2014 and December 2019 for lung cancer, presented 8-15 mm nodule without measurable ground glass component on preoperative CT, and underwent 18F-FDG PET before resection. Image characteristics, including air bronchogram, concave shape, pleural attachment, and background emphysema, were evaluated by two board-certified radiologists. The Mann-Whitney U test was used to compare maximum standardized uptake (SUVmax) values from 18F-FDG PET images.
RESULTS: The analysis included 235 patients. The SUVmax values of lesions with air bronchogram and concave shape were significantly lower than the SUVmax values of lesions without these features (median: 1.55 vs 2.56 and 1.66 vs 2.45, both P < .001), whereas lesions arising from emphysematous lungs had significantly higher SUVmax values than lesions arising from non-emphysematous lungs (2.90 vs 1.69, P < .001). No significant differences were detected between lesions attached and not attached to pleura. The interobserver agreement was almost perfect for air bronchograms and background emphysema (κ = 0.882 and 0.927, respectively), and 89.7% of lesions with air bronchograms and arising from non-emphysematous lungs showed SUVmax values below 2.5.
CONCLUSIONS: Among 8-15 mm solid lung cancer, the presence of air bronchograms and concave shape and the absence of background emphysema were associated with low 18F-FDG accumulation.
ADVANCES IN KNOWLEDGE: 18F-FDG PET can be misleading in differentiating certain type of small solid lung cancer.
引用
- Sugawara H, Kikkawa N, Ito K, et al. Is 18F-fluorodeoxyglucose PET recommended for small lung nodules? CT findings of 18F-fluorodeoxyglucose non-avid lung cancer. Br J Radiol. 2024. PMID: 38308036. doi:10.1093/bjr/tqad048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。