三维伪连续动脉自旋标记灌注成像全结直方图分析诊断鼻咽癌患者上颈淋巴结转移
回顾性纳入80例鼻咽癌患者共170枚经组织学证实的上颈淋巴结(67枚良性、103枚转移),评估治疗前三维伪连续动脉自旋标记血流量图的全结直方图参数及形态学特征。转移淋巴结的最小轴径、最小轴径/最大轴径比值、能量和熵值更大,II区(上颈静脉组)发生率更高,而BF10th值更低。联合模型诊断转移的AUC为0.932,准确率84.42%,敏感度80.6%,特异度90.29%。
要点
- 转移性上颈淋巴结BF10th值低于良性淋巴结,能量和熵值更高。
- 最小轴径、BF10th、能量和熵为诊断转移的独立预测因子。
- 联合模型诊断转移的AUC为0.932,特异度90.29%,敏感度80.6%。
核心结论
- 基于血流量图的全结直方图分析是区分鼻咽癌患者转移性与良性上颈淋巴结的可行工具,联合模型可进一步提高诊断效能。
研究设计与样本
- 回顾性研究纳入80例鼻咽癌患者共170枚经组织学证实的上颈淋巴结(67枚良性、103枚转移),于治疗前行三维伪连续动脉自旋标记成像并行全结直方图分析,以组织学为参考标准。
关键影像表现/征象
- 转移性上颈淋巴结较良性淋巴结有更大的最小轴径和最小轴径/最大轴径比值、更高的能量和熵值、更高的II区(上颈静脉组)发生率,以及更低的BF10th值(均p<0.05)。
诊断标准与关键数值
- 最小轴径、BF10th、能量和熵被验证为诊断转移性上颈淋巴结的独立预测因子。
- 联合模型诊断转移性上颈淋巴结的AUC为0.932,准确率84.42%,敏感度80.6%,特异度90.29%。
临床应用与阅片要点
- 原文结论认为全结直方图分析血流量图是区分转移性与良性上颈淋巴结的可行工具,联合模型可进一步提高诊断效能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate whole-node histogram parameters of blood flow (BF) maps derived from three-dimensional pseudo-continuous arterial spin-labelled (3D pCASL) imaging in discriminating metastatic from benign upper cervical lymph nodes (UCLNs) for nasopharyngeal carcinoma (NPC) patients.
MATERIALS AND METHODS: Eighty NPC patients with a total of 170 histologically confirmed UCLNs (67 benign and 103 metastatic) were included retrospectively. Pre-treatment 3D pCASL imaging was performed and whole-node histogram analysis was then applied. Histogram parameters and morphological features, such as minimum axis diameter (MinAD), maximum axis diameter (MaxAD), and location of UCLNs, were assessed and compared between benign and metastatic lesions. Predictors were identified and further applied to establish a combined model by multivariate logistic regression in predicting the probability of metastatic UCLNs. Receiver operating characteristic (ROC) curves were used to analyse the diagnostic performance.
RESULTS: Metastatic UCLNs had larger MinAD and MinAD/MaxAD ratio, greater energy and entropy values, and higher incidence of level II (upper jugular group), but lower BF10th value than benign nodes (all p<0.05). MinAD, BF10th, energy, and entropy were validated as independent predictors in diagnosing metastatic UCLNs. The combined model yielded an area under the curve (AUC) of 0.932, accuracy of 84.42 %, sensitivity of 80.6 %, and specificity of 90.29 %.
CONCLUSIONS: Whole-node histogram analysis on BF maps is a feasible tool to differentiate metastatic from benign UCLNs in NPC patients, and the combined model can further improve the diagnostic efficacy.
引用
- Shao L, Yang X, Sun Z, et al. Three-dimensional pseudo-continuous arterial spin-labelled perfusion imaging for diagnosing upper cervical lymph node metastasis in patients with nasopharyngeal carcinoma: a whole-node histogram analysis. Clin Radiol. 2024. PMID: 38341343. doi:10.1016/j.crad.2024.01.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。