比较不同采集平面磁敏感图加权MRI在神经退行性帕金森综合征诊断中的性能
回顾性单机构研究纳入194例运动障碍门诊患者,比较斜位与AC-PC平面SMwI鉴别神经退行性帕金森综合征的诊断性能,以18F-FP-CIT PET为参考标准。两平面敏感度与特异度无显著差异(P>0.05),结论为各机构可按临床设置选择采集平面。
要点
- SMwI斜位与AC-PC平面诊断性能无显著差异(P>0.05)。
- 两平面观察者间一致性良好(κ=0.658–0.772)。
- 以18F-FP-CIT PET为参考标准,各机构可按临床设置选择平面。
核心结论
- SMwI在斜位与AC-PC平面鉴别帕金森综合征患者与无该病患者时诊断性能无显著差异(P>0.05),各机构可按临床设置选择成像平面。
研究设计与样本
- 回顾性、观察性、单机构研究,纳入2021年9月至2021年12月连续就诊于运动障碍门诊并接受脑MRI与18F-FP-CIT PET的患者194例,由两位神经放射学家判读黑质高信号,以18F-FP-CIT PET为参考标准。
诊断标准与关键数值
- 斜位平面两位阅片者合并敏感度左侧86.4%(178/206)、右侧83.3%(175/210),AC-PC平面左侧87.4%(180/206)、右侧87.6%(184/210)。
- 斜位平面两位阅片者合并特异度左侧83.5%(152/182)、右侧82.0%(146/178),AC-PC平面左侧83.5%(152/182)、右侧86.0%(153/178)。
- 两平面诊断性能比较无显著差异(P>0.05)。
- 斜位平面观察者间一致性κ=0.772(左)/0.658(右),AC-PC平面κ=0.730(左)/0.741(右)。
临床应用与阅片要点
- 各机构可根据自身临床设置选择SMwI的采集平面。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic performance of susceptibility map-weighted imaging (SMwI) taken in different acquisition planes for discriminating patients with neurodegenerative parkinsonism from those without.
MATERIALS AND METHODS: This retrospective, observational, single-institution study enrolled consecutive patients who visited movement disorder clinics and underwent brain MRI and 18F-FP-CIT PET between September 2021 and December 2021. SMwI images were acquired in both the oblique (perpendicular to the midbrain) and the anterior commissure-posterior commissure (AC-PC) planes. Hyperintensity in the substantia nigra was determined by two neuroradiologists. 18F-FP-CIT PET was used as the reference standard. Inter-rater agreement was assessed using Cohen's kappa coefficient. The diagnostic performance of SMwI in the two planes was analyzed separately for the right and left substantia nigra. Multivariable logistic regression analysis with generalized estimating equations was applied to compare the diagnostic performance of the two planes.
RESULTS: In total, 194 patients were included, of whom 105 and 103 had positive results on 18F-FP-CIT PET in the left and right substantia nigra, respectively. Good inter-rater agreement in the oblique (κ = 0.772/0.658 for left/right) and AC-PC planes (0.730/0.741 for left/right) was confirmed. The pooled sensitivities for two readers were 86.4% (178/206, left) and 83.3% (175/210, right) in the oblique plane and 87.4% (180/206, left) and 87.6% (184/210, right) in the AC-PC plane. The pooled specificities for two readers were 83.5% (152/182, left) and 82.0% (146/178, right) in the oblique plane, and 83.5% (152/182, left) and 86.0% (153/178, right) in the AC-PC plane. There were no significant differences in the diagnostic performance between the two planes (P > 0.05).
CONCLUSION: There are no significant difference in the diagnostic performance of SMwI performed in the oblique and AC-PC plane in discriminating patients with parkinsonism from those without. This finding affirms that each institution may choose the imaging plane for SMwI according to their clinical settings.
引用
- Lee S, Suh CH, Jo S, et al. Comparative Performance of Susceptibility Map-Weighted MRI According to the Acquisition Planes in the Diagnosis of Neurodegenerative Parkinsonism. Korean J Radiol. 2024. PMID: 38413111. doi:10.3348/kjr.2023.0920
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。