深度学习重建的垂体高分辨率3D MRI在垂体腺瘤围手术期评估中的价值
本研究对24例垂体腺瘤或残留肿瘤患者行增强MRI,比较CUBE序列联合深度学习重建(DLR)与CUBE不联合DLR、1mm 2D T1WI联合DLR及3D SPGR的图像质量。结果显示CUBE联合DLR在显示垂体腺瘤或残留肿瘤方面评分显著更高,且观察者间一致性优于1mm 2D T1WI联合DLR。
要点
- CUBE联合DLR对垂体腺瘤或残留肿瘤的显示评分显著高于CUBE不联合DLR、1mm 2D T1WI联合DLR和SPGR(p<0.01)。
- CUBE联合DLR显示腺瘤与海绵窦边界的评分高于1mm 2D T1WI联合DLR(p=0.01),但与SPGR差异无统计学意义(p=0.20)。
- CUBE联合DLR评估腺瘤的观察者间一致性Kappa值为0.75,优于1mm 2D T1WI联合DLR的0.41。
核心结论
- 在增强MRI上,与CUBE不联合DLR、1mm 2D T1WI联合DLR和SPGR相比,CUBE联合DLR改善了垂体腺瘤和鞍旁区域的显示。
研究设计与样本
- 研究纳入24例垂体腺瘤或残留肿瘤患者,采用CUBE联合与不联合DLR、1mm层厚2D T1WI联合DLR及3D SPGR行增强MRI,由两名神经放射科医生进行显示评分并计算对比噪声比(CNR)。
关键影像表现/征象
- CUBE联合DLR显示垂体腺瘤或残留肿瘤的评分显著高于CUBE不联合DLR、1mm 2D T1WI联合DLR和SPGR(p<0.01)。
- CUBE联合DLR显示腺瘤与海绵窦边界的评分高于1mm 2D T1WI联合DLR(p=0.01),但与SPGR相比差异无统计学意义(p=0.20)。
- CUBE联合DLR评估腺瘤的观察者间一致性Kappa值为0.75,1mm 2D T1WI联合DLR为0.41。
- 腺瘤与脑实质的CNR从CUBE不联合DLR的3.8增至CUBE联合DLR的13.7,比值为3.6(p<0.01)。
- CUBE联合DLR的CNR显著高于SPGR,但与1mm 2D T1WI联合DLR相比差异无统计学意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic value of T1-weighted 3D fast spin-echo sequence (CUBE) with deep learning-based reconstruction (DLR) for depiction of pituitary adenoma and parasellar regions on contrast-enhanced MRI.
METHODS: We evaluated 24 patients with pituitary adenoma or residual tumor using CUBE with and without DLR, 1-mm slice thickness 2D T1WI (1-mm 2D T1WI) with DLR, and 3D spoiled gradient echo sequence (SPGR) as contrast-enhanced MRI. Depiction scores of pituitary adenoma and parasellar regions were assigned by two neuroradiologists, and contrast-to-noise ratio (CNR) was calculated.
RESULTS: CUBE with DLR showed significantly higher scores for depicting pituitary adenoma or residual tumor compared to CUBE without DLR, 1-mm 2D T1WI with DLR, and SPGR (p < 0.01). The depiction score for delineation of the boundary between adenoma and the cavernous sinus was higher for CUBE with DLR than for 1-mm 2D T1WI with DLR (p = 0.01), but the difference was not significant when compared to SPGR (p = 0.20). CUBE with DLR had better interobserver agreement for evaluating adenomas than 1-mm 2D T1WI with DLR (Kappa values, 0.75 vs. 0.41). The CNR of the adenoma to the brain parenchyma increased to a ratio of 3.6 (obtained by dividing 13.7, CNR of CUBE with DLR, by 3.8, that without DLR, p < 0.01). CUBE with DLR had a significantly higher CNR than SPGR, but not 1-mm 2D T1WI with DLR.
CONCLUSION: On the contrast-enhanced MRI, compared to CUBE without DLR, 1-mm 2D T1WI with DLR and SPGR, CUBE with DLR improves the depiction of pituitary adenoma and parasellar regions.
引用
- Ishimoto Y, Ide S, Watanabe K, et al. Usefulness of pituitary high-resolution 3D MRI with deep-learning-based reconstruction for perioperative evaluation of pituitary adenomas. Neuroradiology. 2024. PMID: 38374411. doi:10.1007/s00234-024-03315-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。