文献速递神经外周血管CT

双能CT评估急性缺血性卒中血栓切除术后脑出血:临床实践中的可靠性如何

Assessment of post-thrombectomy brain hemorrhage in acute ischemic stroke with dual-energy CT: how reliable is it in clinical practice?
PubMed 文献 · Radiol Med · 2024-02-17

该回顾性研究纳入44例在都灵San Giovanni Bosco医院接受血管内再通治疗的急性缺血性卒中患者,术后行双能CT(DECT)检查,以后续扫描为标准。DECT检出血液者随访发生出血性梗死的风险为无血液者的2.02倍(RR 2.02);DECT敏感度70%、特异度90%、总诊断准确率76%,阳性预测值95%、阴性预测值53%。作者认为DECT识别早期出血性梗死具有极好特异度和良好总体诊断准确率,是日常临床实践中可靠的诊断工具。

要点

  • DECT术后检出血液者随访出血性梗死风险为无血液者的2.02倍(RR 2.02)。
  • DECT诊断出血性梗死的敏感度70%、特异度90%、总准确率76%。
  • 阳性预测值95%、阴性预测值53%,特异度高而敏感度中等。

核心结论

  • 血管内再通治疗后双能CT可识别早期出血性梗死,特异度极好、总体诊断准确率良好,是日常临床实践中可靠的诊断工具。

研究设计与样本

  • 回顾性研究,纳入44例在都灵San Giovanni Bosco医院接受血管内再通治疗的急性缺血性卒中患者,术后行DECT检查,以后续扫描为参考标准。

关键影像表现/征象

  • 双能CT利用区分不同物质的能力鉴别血液与碘对比剂。
  • 术后即刻脑CT难以区分血液与因血脑屏障破坏而存在于缺血组织中的碘对比剂。

诊断标准与关键数值

  • DECT诊断出血性梗死的敏感度70%、特异度90%。
  • 总诊断准确率76%,阳性预测值95%、阴性预测值53%。
  • DECT检出血液者随访出血性梗死的相对危险度RR 2.02。
  • χ²检验显示DECT术后检出血液与后续扫描同一区域存在血液相关:χ²(1, N=37)=10.7086,p=0.0010。

临床应用与阅片要点

  • 血管内再通治疗后可行双能CT评估围手术期并发症,以区分血液与碘对比剂。
  • 后续扫描作为标准,因对比剂染色中的碘通常在24小时内吸收而血液持续更久。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Acute ischemic stroke is currently among the main causes of mortality in Western countries. The current guidelines suggest different flowcharts of diagnostic work-up and treatment modalities, including endovascular thrombectomy. Immediately after intra-arterial recanalization, a brain CT scan is usually performed to assess for the presence of peri-procedural complications; in this setting, it is very hard, if possible, to differentiate blood from iodinated contrast material, which is normally present in ischemic tissue because of BBB disruption. Dual-energy CT may be used for this purpose, exploiting its ability to discriminate different materials.

MATERIALS AND METHODS: We retrospectively studied 44 patients with acute ischemic stroke who were treated with endovascular recanalization at San Giovanni Bosco Hospital in Turin and were then scanned with DECT technology. Subsequent scan was used as standard, since iodine from contrast staining is usually reabsorbed in 24 h and blood persists longer. A χ2 test of independence was performed to examine the relationship between blood detected by DECT scan after the endovascular procedure and the presence of blood in the same areas on the following scans, with a significant result: χ2 (1, N = 37) = 10.7086, p = 0.0010.

RESULTS: Patients with blood detected on DECT scans had a double chance of having hemorrhagic infarction in follow-up scans, (RR 2.02). The sensitivity and specificity of DECT were respectively 70% and 90%, with an overall diagnostic accuracy of 76% and a positive and negative predictive value, respectively, of 95% and 53%.

CONCLUSION: Dual-energy CT scan after endovascular recanalization in ischemic stroke identifies early hemorrhagic infarction with excellent specificity and good overall diagnostic accuracy, representing a reliable diagnostic tool in everyday clinical practice.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Pacielli A, Vaudano GP, Bergamasco L, et al. Assessment of post-thrombectomy brain hemorrhage in acute ischemic stroke with dual-energy CT: how reliable is it in clinical practice? Radiol Med. 2024. PMID: 38368280. doi:10.1007/s11547-023-01749-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。