文献速递神经外周血管CT

利用对侧局部归一化减少CT灌注梗死核心分割中的假阳性

Reducing False-Positives in CT Perfusion Infarct Core Segmentation Using Contralateral Local Normalization.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-03-07

回顾性纳入2830例疑似缺血性卒中CTP扫描,其中335例有明显微血管病变征象,在常规全局归一化基础上加用对侧镜像平滑局部归一化。局部归一化使有明显微血管病变病例的假阳性体积从平均14.7 mL降至平均3.7 mL,核心体积平均略小,提示分割对深部白质天然低血流值更稳健。

要点

  • 对侧局部归一化可减少CTP梗死核心分割的假阳性,尤其深部白质和明显微血管病变病例。
  • 有明显微血管病变病例假阳性体积平均14.7 mL vs 无微血管病变病例平均3.7 mL。
  • 局部归一化后核心体积平均略小,提示分割对深部白质天然低血流值更稳健。

核心结论

  • 所提出的局部归一化方法可减少梗死核心高估,尤其深部白质和明显微血管病变病例;CTP梗死核心分割假阳性若未正确解读可能导致次优治疗决策,该方法可能有助于缓解此问题。

研究设计与样本

  • 回顾性纳入2830例疑似缺血性卒中CTP扫描,其中335例有明显微血管病变征象;在常规全局归一化(正常灌注组织的中位值)基础上,将对侧镜像平滑后的rCBF图与原始rCBF图相除进行局部归一化,对两种方法分别目视评估并计算核心体积。

诊断标准与关键数值

  • 常规梗死核心分割采用rCBF<30%的全局阈值。
  • 局部归一化通过将rCBF图除以其镜像平滑对侧图,使每个体素值与对侧对应值相关,内在校正灰白质差异和对称的个体微血管病变。
  • 有明显微血管病变病例假阳性体积平均14.7 mL vs 无微血管病变病例平均3.7 mL。

临床应用与阅片要点

  • 作者建议在全局归一化之外加用对侧局部归一化,以减少梗死核心假阳性,尤其深部白质和明显微血管病变病例。
  • 作者指出CTP梗死核心分割假阳性若未正确解读可能导致次优治疗决策,所提方法可能有助于缓解此问题。

局限性

  • 原文为回顾性研究。
  • 原文报告所提方法可能有助于缓解假阳性问题,未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The established global threshold of rCBF <30% for infarct core segmentation can lead to false-positives, as it does not account for the differences in blood flow between GM and WM and patient-individual factors, such as microangiopathy. To mitigate this problem, we suggest normalizing each voxel not only with a global reference value (ie, the median value of normally perfused tissue) but also with its local contralateral counterpart.

MATERIALS AND METHODS: We retrospectively enrolled 2830 CTP scans with suspected ischemic stroke, of which 335 showed obvious signs of microangiopathy. In addition to the conventional, global normalization, a local normalization was performed by dividing the rCBF maps with their mirrored and smoothed counterpart, which sets each voxel value in relation to the contralateral counterpart, intrinsically accounting for GM and WM differences and symmetric patient individual microangiopathy. Maps were visually assessed and core volumes were calculated for both methods.

RESULTS: Cases with obvious microangiopathy showed a strong reduction in false-positives by using local normalization (mean 14.7 mL versus mean 3.7 mL in cases with and without microangiopathy). On average, core volumes were slightly smaller, indicating an improved segmentation that was more robust against naturally low blood flow values in the deep WM.

CONCLUSIONS: The proposed method of local normalization can reduce overestimation of the infarct core, especially in the deep WM and in cases with obvious microangiopathy. False-positives in CTP infarct core segmentation might lead to less-than-optimal therapy decisions when not correctly interpreted. The proposed method might help mitigate this problem.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Rau A, Reisert M, Taschner CA, et al. Reducing False-Positives in CT Perfusion Infarct Core Segmentation Using Contralateral Local Normalization. AJNR Am J Neuroradiol. 2024. PMID: 38302197. doi:10.3174/ajnr.A8111

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。