成人颅内室管膜瘤增强T1加权与表观扩散系数全肿瘤直方图分析预测分级与增殖活性
本研究纳入47例成人颅内室管膜瘤,提取增强T1加权(T1C)和表观扩散系数(ADC)的全肿瘤直方图参数,比较2级与3级肿瘤间差异,并用ROC曲线和逻辑回归评估诊断性能。3级肿瘤T1C的Perc.95、Perc.99、SD、方差、CV和熵更高,ADC最小值、均值及多个低百分位数更低,ADC的CV和熵更高;T1C熵和ADC Perc.10的AUC分别为0.805和0.827,两者联合AUC为0.857。
要点
- 3级成人颅内室管膜瘤T1C直方图熵和ADC Perc.10的诊断AUC分别为0.805和0.827。
- T1C熵与ADC Perc.10联合可将分级诊断AUC提升至0.857。
- T1C与ADC的显著直方图参数与Ki-67增殖指数存在相关性(r=0.296-0.417及r=-0.428-0.395)。
核心结论
- T1C和ADC的全肿瘤直方图分析可能是有望用于预测成人颅内室管膜瘤分级和增殖活性的方法。
研究设计与样本
- 纳入47例成人颅内室管膜瘤,使用FireVoxel软件提取T1C和ADC的直方图参数(包括最小值、最大值、均值、Perc.01、Perc.05、Perc.10、Perc.25、Perc.50、Perc.75、Perc.90、Perc.95、Perc.99、SD、方差、CV、偏度、峰度和熵),比较2级与3级肿瘤间差异,采用ROC曲线和逻辑回归分析评估诊断性能,用Spearman相关分析评估直方图参数与Ki-67增殖指数的关系。
关键影像表现/征象
- 3级组T1C的Perc.95、Perc.99、SD、方差、CV和熵显著高于2级组(均p<0.05)。
- 3级组ADC的最小值、均值、Perc.01、Perc.05、Perc.10、Perc.25、Perc.50显著低于2级组(均p<0.05)。
- 3级组ADC的CV和熵显著高于2级组(均p<0.05)。
诊断标准与关键数值
- T1C熵诊断2级与3级成人颅内室管膜瘤的AUC为0.805。
- ADC Perc.10诊断2级与3级成人颅内室管膜瘤的AUC为0.827。
- T1C熵联合ADC Perc.10诊断2级与3级成人颅内室管膜瘤的AUC为0.857。
- T1C显著直方图参数与Ki-67增殖指数的相关系数r=0.296-0.417(p=0.001-0.044)。
- ADC显著直方图参数与Ki-67增殖指数的相关系数r=-0.428-0.395(p=0.003-0.038)。
临床应用与阅片要点
- 作者认为T1C和ADC的全肿瘤直方图分析可能是有望预测成人颅内室管膜瘤分级和增殖活性的方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the value of histogram analysis of postcontrast T1-weighted (T1C) and apparent diffusion coefficient (ADC) images in predicting the grade and proliferative activity of adult intracranial ependymomas.
METHODS: Forty-seven adult intracranial ependymomas were enrolled and underwent histogram parameters extraction (including minimum, maximum, mean, 1st percentile (Perc.01), Perc.05, Perc.10, Perc.25, Perc.50, Perc.75, Perc.90, Perc.95, Perc.99, standard deviation (SD), variance, coefficient of variation (CV), skewness, kurtosis, and entropy of T1C and ADC) using FireVoxel software. Differences in histogram parameters between grade 2 and grade 3 adult intracranial ependymomas were compared. Receiver operating characteristic curves and logistic regression analyses were conducted to evaluate the diagnostic performance. Spearman's correlation analysis was used to evaluate the relationship between histogram parameters and Ki-67 proliferation index.
RESULTS: Grade 3 intracranial ependymomas group showed significantly higher Perc.95, Perc.99, SD, variance, CV, and entropy of T1C; lower minimum, mean, Perc.01, Perc.05, Perc.10, Perc.25, Perc.50 of ADC; and higher CV and entropy of ADC than grade 2 intracranial ependymomas group (all p < 0.05). Entropy (T1C) and Perc.10 (ADC) had a higher diagnostic performance with AUCs of 0.805 and 0.827 among the histogram parameters of T1C and ADC, respectively. The diagnostic performance was improved by combining entropy (T1C) and Perc.10 (ADC), with an AUC of 0.857. Significant correlations were observed between significant histogram parameters of T1C (r = 0.296-0.417, p = 0.001-0.044) and ADC (r = -0.428-0.395, p = 0.003-0.038).
CONCLUSION: Whole-tumor histogram analysis of T1C and ADC may be a promising approach for predicting the grade and proliferative activity of adult intracranial ependymomas.
引用
- Liu X, Han T, Wang Y, et al. Whole-tumor histogram analysis of postcontrast T1-weighted and apparent diffusion coefficient in predicting the grade and proliferative activity of adult intracranial ependymomas. Neuroradiology. 2024. PMID: 38400953. doi:10.1007/s00234-024-03319-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。