基于视觉Transformer与规则分类的颈椎椎管狭窄及脊髓受压自动检测
本研究纳入142例颈椎MRI,使用预训练视觉Transformer(ViT)模型在梯度回波图像上进行节段级严重程度分类,并以最高节段严重程度判定检查整体严重程度,其中≥1个节段预测为重度即判定为脊髓受压阳性。ViT节段级准确率为82%,患者级准确率93%、敏感度0.90、特异度0.95,受试者工作特征曲线下面积大于两种卷积神经网络模型。
要点
- ViT模型患者级检测脊髓受压的敏感度0.90、特异度0.95、阳性预测值0.90、阴性预测值0.95。
- ViT节段级准确率82%,高于ResNet50的72%和DenseNet121的78%。
- 检查整体严重程度取最高节段严重程度,≥1个节段预测为重度即判为脊髓受压阳性。
核心结论
- 使用ViT模型和规则分类的该方法在患者 level 准确检测颈椎脊髓受压的存在,ViT在节段和患者水平均优于两种常规CNN方法。
研究设计与样本
- 研究纳入142例临床多样性颈椎MRI,其中34%正常或轻度狭窄、31%中度狭窄、35%脊髓受压;使用梯度回波图像,由神经放射学教师确认椎管分割;预训练ViT模型按60:20:20分为训练集、验证集和测试集进行微调,并以相同方式测试ResNet50和DenseNet121两种CNN模型。
诊断标准与关键数值
- 节段级标注为无脊髓受压/轻度狭窄、中度狭窄或重度狭窄/脊髓受压;检查整体严重程度取最高节段严重程度,≥1个节段预测为重度即判定该检查脊髓受压阳性;ViT节段级准确率82%,ResNet50为72%,DenseNet121为78%;ViT患者级准确率93%、敏感度0.90、阳性预测值0.90、特异度0.95、阴性预测值0.95;ViT的受试者工作特征曲线下面积大于两种CNN。
临床应用与阅片要点
- 作者认为,若将该工具应用于临床环境,可能简化神经放射学工作流程,提高效率和一致性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Cervical spinal cord compression, defined as spinal cord deformity and severe narrowing of the spinal canal in the cervical region, can lead to severe clinical consequences, including intractable pain, sensory disturbance, paralysis, and even death, and may require emergent intervention to prevent negative outcomes. Despite the critical nature of cord compression, no automated tool is available to alert clinical radiologists to the presence of such findings. This study aims to demonstrate the ability of a vision transformer (ViT) model for the accurate detection of cervical cord compression.
MATERIALS AND METHODS: A clinically diverse cohort of 142 cervical spine MRIs was identified, 34% of which were normal or had mild stenosis, 31% with moderate stenosis, and 35% with cord compression. Utilizing gradient-echo images, slices were labeled as no cord compression/mild stenosis, moderate stenosis, or severe stenosis/cord compression. Segmentation of the spinal canal was performed and confirmed by neuroradiology faculty. A pretrained ViT model was fine-tuned to predict section-level severity by using a train:validation:test split of 60:20:20. Each examination was assigned an overall severity based on the highest level of section severity, with an examination labeled as positive for cord compression if ≥1 section was predicted in the severe category. Additionally, 2 convolutional neural network (CNN) models (ResNet50, DenseNet121) were tested in the same manner.
RESULTS: The ViT model outperformed both CNN models at the section level, achieving section-level accuracy of 82%, compared with 72% and 78% for ResNet and DenseNet121, respectively. ViT patient-level classification achieved accuracy of 93%, sensitivity of 0.90, positive predictive value of 0.90, specificity of 0.95, and negative predictive value of 0.95. Receiver operating characteristic area under the curve was greater for ViT than either CNN.
CONCLUSIONS: This classification approach using a ViT model and rules-based classification accurately detects the presence of cervical spinal cord compression at the patient level. In this study, the ViT model outperformed both conventional CNN approaches at the section and patient levels. If implemented into the clinical setting, such a tool may streamline neuroradiology workflow, improving efficiency and consistency.
引用
- Payne DL, Xu X, Faraji F, et al. Automated Detection of Cervical Spinal Stenosis and Cord Compression via Vision Transformer and Rules-Based Classification. AJNR Am J Neuroradiol. 2024. PMID: 38360785. doi:10.3174/ajnr.A8141
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。