图像对比度、分辨率及读片者经验对多发性硬化黑洞识别的影响
前瞻性单中心研究纳入85例多发性硬化患者,比较3 mm SE-T1w、1 mm 3D-GrE-T1w及由其重切的3 mm序列对黑洞识别的信度。两位不同经验读片者间隔30天重复评估,结果显示3 mm SE-T1w与3 mm重切GrE-T1w的读片者内ICC≥0.95,1 mm 3D-GrE-T1w的ICC<0.90;三种序列读片者间ICC均<0.90。作者认为1 mm 3D-GrE-T1w序列读片者内变异更大,推荐在3 mm重切GrE-T1w序列上评估以获与标准SE-T1w相当的可靠性。
要点
- 3 mm SE-T1w与3 mm重切GrE-T1w读片者内ICC均≥0.95,1 mm 3D-GrE-T1w仅ICC<0.90。
- 三种序列读片者间ICC均<0.90,提示读片者间一致性有限。
- 作者推荐在3 mm重切GrE-T1w序列上评估黑洞计数以保证可靠性。
核心结论
- 1 mm 3D-GrE-T1w序列读片者内变异似乎大于3 mm SE-T1w,该效应由前者更高的空间分辨率驱动。
- 作者推荐在3 mm重切GrE-T1w序列上评估黑洞计数,以获得与标准SE-T1w相当的可靠性水平。
研究设计与样本
- 前瞻性单中心研究,纳入85例多发性硬化患者(男/女=22/63,平均年龄36.0±10.2岁)。
- 采集方案包括3 mm SE-T1w序列、1 mm 3D-GrE-T1w序列,并由后者重切获得3 mm序列。
- 由两位不同经验读片者独立评估,基线及30天洗脱期后重复评估,以组内相关系数(ICC)作为读片者内与读片者间信度指标。
诊断标准与关键数值
- 读片者内ICC:3 mm SE-T1w与3 mm重切GrE-T1w均≥0.95(表现优秀),1 mm 3D-GrE-T1w<0.90(表现中等)。
- 读片者间ICC:三种序列均<0.90(表现中等)。
临床应用与阅片要点
- 作者推荐在3 mm重切GrE-T1w序列上进行黑洞计数评估,以获得与标准SE-T1w相当的可靠性水平。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: In the neuroradiological work-up of Multiple Sclerosis (MS), the detection of "black holes" (BH) represent an information of undeniable importance. Nevertheless, different sequences can be used in clinical practice to evaluate BH in MS. Aim of this study was to investigate the possible impact of different sequences, resolutions, and levels of expertise on the intra- and inter-rater reliability identification of BH in MS.
METHODS: Brain MRI scans of 85 MS patients (M/F = 22/63; mean age = 36.0 ± 10.2 years) were evaluated in this prospective single-center study. The acquisition protocol included a 3 mm SE-T1w sequence, a 1 mm 3D-GrE-T1w sequence from which a resliced 3 mm sequence was also obtained. Images were evaluated independently by two readers of different expertise at baseline and after a wash-out period of 30 days. The intraclass correlation coefficient (ICC) was calculated as an index of intra and inter-reader reliability.
RESULTS: For both readers, the intra-reader ICC analysis showed that the 3 mm SE-T1w and 3 mm resliced GrE-T1w images achieved an excellent performance (both with an ICC ≥ 0.95), while 1 mm 3D-GrE-T1w scans achieved a moderate one (ICC < 0.90). The inter-reader analysis showed that each of the three sequences achieved a moderate performance (all ICCs < 0.90).
CONCLUSIONS: The 1 mm 3D-GrE-T1w sequence seems to be prone to a greater intra-reader variability compared to the 3 mm SE-T1w, with this effect being driven by the higher spatial resolution of the first sequence. To ensure reliability levels comparable with the standard SE-T1w in BH count, an assessment on a 3 mm resliced GrE-T1w sequence should be recommended.
引用
- Tranfa M, Scaravilli A, Pastore C, et al. The impact of image contrast, resolution and reader expertise on black hole identification in Multiple Sclerosis. Neuroradiology. 2024. PMID: 38374410. doi:10.1007/s00234-024-03310-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。