迈向更安全的影像检查:基于活体大型动物模型的个体内低剂量CT扫描中深度学习去噪与迭代重建的比较研究

Towards safer imaging: A comparative study of deep learning-based denoising and iterative reconstruction in intraindividual low-dose CT scans using an in-vivo large animal model.
PubMed 文献 · Eur J Radiol · 2023-12-19

研究对14只镇静活猪在同一第三代双源CT上行个体内扫描,将mAs降至50%、25%、10%和5%,分别用ADMIRE 2级迭代重建(IR2)与新型深度学习去噪(DLD)重建共280组数据集。DLD在25%辐射剂量下的噪声(p=0.544)和CNR(p=0.115)与100% IR2无显著差异,主观评分亦具可比性(p≥0.281),提示DLD可在不牺牲诊断质量的前提下实现最高75%的剂量降低。

要点

  • DLD在25%辐射剂量下的噪声与CNR与100%剂量IR2无显著差异(p=0.544、p=0.115)。
  • 主观评分显示25%剂量DLD在图像质量、锐利度和对比度上与100% IR2可比(p≥0.281)。
  • 剂量降低与重建方法均未对CT值稳定性产生负面影响(p>0.999)。

核心结论

  • DLD算法可达到与标准IR方法相当的图像质量,同时实现最高75%的显著剂量降低,提示在不牺牲诊断质量的前提下降低患者辐射暴露具有前景。

研究设计与样本

  • 活体大型动物个体内比较研究,14只兽医镇静的活猪在同一第三代双源CT上间隔两个月行2次CT扫描,每次额外行mAs降至50%、25%、10%和5%的4次扫描,全部扫描分别用ADMIRE 2级(IR2)和新型DLD算法重建,共280组数据集。

诊断标准与关键数值

  • 以100%剂量IR2为参照,DLD噪声(p=0.544)和CNR(p=0.115)可达到的最低辐射剂量为25%;主观图像质量评分者间一致性高(r≥0.69,平均0.93±0.05,95%CI 0.92-0.94,各p<0.001)。

临床应用与阅片要点

  • DLD在25%辐射剂量下噪声、CNR及主观图像质量、锐利度、对比度与100%剂量IR2无显著差异(p≥0.281)。
  • 剂量降低与重建方法均未对CT值稳定性产生负面影响(p>0.999)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Computed tomography (CT) scans are a significant source of medically induced radiation exposure. Novel deep learning-based denoising (DLD) algorithms have been shown to enable diagnostic image quality at lower radiation doses than iterative reconstruction (IR) methods. However, most comparative studies employ low-dose simulations due to ethical constraints. We used real intraindividual animal scans to investigate the dose-reduction capabilities of a DLD algorithm in comparison to IR.

MATERIALS AND METHODS: Fourteen veterinarian-sedated alive pigs underwent 2 CT scans on the same 3rd generation dual-source scanner with two months between each scan. Four additional scans ensued each time, with mAs reduced to 50 %, 25 %, 10 %, and 5 %. All scans were reconstructed ADMIRE levels 2 (IR2) and a novel DLD algorithm, resulting in 280 datasets. Objective image quality (CT numbers stability, noise, and contrast-to-noise ratio) was measured via consistent regions of interest. Three radiologists independently rated all possible dataset combinations per time point for subjective image quality (-1 = inferior, 0 = equal, 1 = superior). The points were averaged for a semiquantitative score, and inter-rater agreement was measured using Spearman's correlation coefficient and adequately corrected mixed-effects modeling analyzed objective and subjective image quality.

RESULTS: Neither dose-reduction nor reconstruction method negatively impacted CT number stability (p > 0.999). In objective image quality assessment, the lowest radiation dose achievable by DLD when comparing noise (p = 0.544) and CNR (p = 0.115) to 100 % IR2 was 25 %. Overall, inter-rater agreement of the subjective image quality ratings was strong (r ≥ 0.69, mean 0.93 ± 0.05, 95 % CI 0.92-0.94; each p < 0.001), and subjective assessments corroborated that DLD at 25 % radiation dose was comparable to 100 % IR2 in image quality, sharpness, and contrast (p ≥ 0.281).

CONCLUSIONS: The DLD algorithm can achieve image quality comparable to the standard IR method but with a significant dose reduction of up to 75%. This suggests a promising avenue for lowering patient radiation exposure without sacrificing diagnostic quality.

来源:Eur J Radiol,查看原文。版权归原作者所有。