超声剪切波弹性成像测量的肌腱弹性模量变化与机械压缩试验的关系
研究使用36条犬趾深屈肌腱,经胶原酶软化或EDC硬化处理后,比较SWE剪切模量与机械压缩模量的变化一致性。两种模量在胶原酶处理后均显著降低、EDC处理后均显著升高,PBS对照无显著差异;以压缩模量变化百分比为因变量的回归分析呈指数函数关系,决定系数为0.687。结论认为化学处理诱导的肌腱压缩模量与SWE剪切模量变化相关性约为70%。
要点
- 胶原酶软化肌腱后,压缩模量与SWE剪切模量均显著降低。
- EDC硬化肌腱后,压缩模量与SWE剪切模量均显著升高。
- 压缩模量变化百分比与SWE剪切模量变化的回归决定系数为0.687。
核心结论
- 化学处理诱导的肌腱压缩模量与SWE剪切模量变化相关性约为70%。
研究设计与样本
- 实验研究,使用36条犬趾深屈肌腱,随机分为PBS对照组(n=12)、胶原酶处理组(n=12)和EDC处理组(n=12),处理前后分别行SWE测量和机械压缩试验(金标准)。
诊断标准与关键数值
- 以压缩模量变化百分比为因变量、SWE剪切模量为自变量进行回归分析,最佳拟合为指数函数,决定系数为0.687。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to investigate the consistency of the changes in the elastic modulus measured with ultrasound shear wave elastography (SWE) with changes measured through mechanical testing using tendons that were artificially altered by chemical modifications.
METHODS: Thirty-six canine flexor digitorum profundus tendons were used for this experiment. To mimic tendon mechanical property changes induced by tendinopathy conditions, tendons were treated with collagenase to soften the tissue by collagen digestion or with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) to stiffen the tissues through chemical crosslinking. Tendons were randomly assigned to one of three groups: immersion in phosphate-buffered saline (PBS) as a control group (n = 12), collagenase treatment (n = 12) or EDC treatment (n = 12). Immediately following SWE measurement of each tendon, mechanical compression testing was performed as a gold standard to validate the SWE measurement. Both tests were conducted before and after treatment.
RESULTS: The compressive modulus and SWE shear modulus significantly decreased after collagenase treatment. Conversely, both moduli significantly increased after EDC treatment. There was no significant difference in either modulus before or after PBS treatment. As a result of a regression analysis with the percentage change of the compressive modulus as the dependent variable and SWE shear modulus as the independent variable, the best-fit regression was found to be an exponential function and the coefficient of determination was 0.687.
CONCLUSION: The changes in the compressive moduli and SWE shear moduli in tendons induced by chemical treatments were correlated by approximately 70%.
引用
- Iida N, Thoreson AR, Reisdorf RL, et al. Relationship Between the Changes of Tendon Elastic Moduli With Ultrasound Shear Wave Elastography and Mechanical Compression Test. Ultrasound Med Biol. 2024. PMID: 38272742. doi:10.1016/j.ultrasmedbio.2024.01.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。