使用负重计算机断层扫描(WBCT)评估前交叉韧带损伤膝关节不稳定的新方案及初步结果
本研究纳入5例单侧慢性前交叉韧带撕裂男性患者,提出并测试一种负重CT四体位协议,记录辐射剂量、采集时间与耐受性,并由盲法高年资放射科医生测量胫骨前移(ATT)和股胫旋转(FTR)角。结果显示ACL损伤膝在双侧屈膝位ATT和FTR均大于健康膝,方案辐射剂量16.2 mGy、采集时间15分钟、耐受良好且图像质量佳。
要点
- 双侧屈膝位是ATT和FTR差异最明显的体位。
- 屈膝位外侧ATT损伤膝9.1±2.8 cm vs 健康膝4.0±1.8 cm。
- 双侧屈膝位FTR角损伤膝13.5°±7.7 vs 健康膝8.6°±4.6。
核心结论
- 该WBCT协议可定量评估膝关节不稳定,测量不同体位下的ATT和FTR;初步发现ACL损伤膝ATT和FTR升高,尤其在30°屈膝位。
研究设计与样本
- 前瞻性初步研究,纳入5例单侧慢性ACL撕裂男性患者(23-30岁),行双侧膝关节WBCT四体位扫描,由盲法高年资放射科医生评估图像质量并测量ATT和FTR。
关键影像表现/征象
- 所有体位ACL损伤膝的平均ATT和FTR均大于健康膝,双侧屈膝位差异更明显。
- 屈膝位外侧ATT损伤膝为9.1±2.8 cm,健康膝为4.0±1.8 cm。
- 双侧屈膝位FTR角损伤膝为13.5°±7.7,健康膝为8.6°±4.6。
临床应用与阅片要点
- 协议辐射剂量16.2 mGy,采集时间15分钟,患者耐受良好且体位摆放顺利,图像质量良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To propose a protocol for assessing knee instability in ACL-injured knees using weight-bearing computed tomography (WBCT).
MATERIALS AND METHODS: We enrolled five patients with unilateral chronic ACL tears referred for WBCT. Bilateral images were obtained in four positions: bilateral knee extension, bilateral knee flexion, single-leg stance with knee flexion and external rotation, and single-leg stance with knee flexion and internal rotation. The radiation dose, time for protocol acquisition, and patients' tolerance of the procedure were recorded. A blinded senior radiologist assessed image quality and measured the anterior tibial translation (ATT) and femorotibial rotation (FTR) angle in the ACL-deficient and contralateral healthy knee.
RESULTS: All five patients were male, aged 23-30 years old. The protocol resulted in a 16.2 mGy radiation dose and a 15-min acquisition time. The procedure was well-tolerated, and patient positioning was uneventful, providing good-quality images. In all positions, the mean ATT and FTR were greater in ACL-deficient knees versus the healthy knee, with more pronounced differences observed in the bilateral knee flexion position. Mean lateral ATT in the flexion position was 9.1±2.8 cm in the ACL-injured knees versus 4.0±1.8 cm in non-injured knees, and mean FTR angle in the bilateral flexion position was 13.5°±7.7 and 8.6°±4.6 in the injured and non-injured knees, respectively.
CONCLUSION: Our protocol quantitatively assesses knee instability with WBCT, measuring ATT and FTR in diverse knee positions. It employs reasonable radiation, is fast, well-tolerated, and yields high-quality images. Preliminary findings suggest ACL-deficient knees show elevated ATT and FTR, particularly in the 30° flexion position.
引用
- Leão RV, Zelada SRB, Lobo CFT, et al. Assessment of knee instability in ACL-injured knees using weight-bearing computed tomography (WBCT): a novel protocol and preliminary results. Skeletal Radiol. 2024. PMID: 38185734. doi:10.1007/s00256-024-04562-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。