文献速递骨肌MR

肩部标准与深度学习重建快速自旋回波MRI的前瞻性比较

Prospective Comparison of Standard and Deep Learning-reconstructed Turbo Spin-Echo MRI of the Shoulder.
PubMed 文献 · Radiology · 2024-01-01

这项前瞻性单中心研究纳入133例因肩部异常临床转诊行肩部MRI的连续成人患者,比较标准自旋回波与深度学习重建快速自旋回波序列的采集时间、图像质量和诊断信心。深度学习重建序列中位采集时间较标准序列降低69%,整体图像质量、信噪比和伪影评分更高,而病变检出频率、锐利度和诊断信心无显著差异。

要点

  • TSEDL中位采集时间288秒,标准TSE为926秒,降低69%(P < .001)。
  • TSEDL整体图像质量、信噪比和伪影评分均高于标准TSE(均P < .001)。
  • 两序列病变检出频率、锐利度(P = .06)和诊断信心(P = .05)无显著差异。

核心结论

  • 在临床环境中,肩部TSEDL较标准TSE MRI缩短检查时间并提高图像质量,诊断信心相似。

研究设计与样本

  • 前瞻性单中心研究,纳入2023年2月至3月临床转诊行肩部MRI的连续成人患者133例、135侧肩,先行标准TSE序列(质子密度加权和T1加权,作为参考比较),再行前瞻性欠采样加速TSEDL检查;由6名肌骨放射科医师采用四点Likert量表(1分差,4分优)评估。

诊断标准与关键数值

  • 采用四点Likert量表(1分差,4分优)评估整体图像质量、感知信噪比、锐利度、伪影和诊断信心;TSEDL中位采集时间288秒(IQR 288-288秒) vs 标准TSE 926秒(IQR 926-950秒),TSEDL降低69%(P < .001);TSEDL整体图像质量、感知信噪比和伪影评分均更高(均P < .001);病变特征频率(P = .48至> .99)、锐利度(P = .06)和诊断信心(P = .05)两序列相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Deep learning (DL)-based MRI reconstructions can reduce imaging times for turbo spin-echo (TSE) examinations. However, studies that prospectively use DL-based reconstructions of rapidly acquired, undersampled MRI in the shoulder are lacking. Purpose To compare the acquisition time, image quality, and diagnostic confidence of DL-reconstructed TSE (TSEDL) with standard TSE in patients indicated for shoulder MRI. Materials and Methods This prospective single-center study included consecutive adult patients with various shoulder abnormalities who were clinically referred for shoulder MRI between February and March 2023. Each participant underwent standard TSE MRI (proton density- and T1-weighted imaging; conventional TSE sequence was used as reference for comparison), followed by a prospectively undersampled accelerated TSEDL examination. Six musculoskeletal radiologists evaluated images using a four-point Likert scale (1, poor; 4, excellent) for overall image quality, perceived signal-to-noise ratio, sharpness, artifacts, and diagnostic confidence. The frequency of major pathologic features and acquisition times were also compared between the acquisition protocols. The intergroup comparisons were performed using the Wilcoxon signed rank test. Results Overall, 135 shoulders in 133 participants were evaluated (mean age, 47.9 years ± 17.1 [SD]; 73 female participants). The median acquisition time of the TSEDL protocol was lower than that of the standard TSE protocol (288 seconds [IQR, 288-288 seconds] vs 926 seconds [IQR, 926-950 seconds], respectively; P < .001), achieving a 69% lower acquisition time. TSEDL images were given higher scores for overall image quality, perceived signal-to-noise ratio, and artifacts (all P < .001). Similar frequency of pathologic features (P = .48 to > .99), sharpness (P = .06), or diagnostic confidence (P = .05) were noted between images from the two protocols. Conclusion In a clinical setting, TSEDL led to reduced examination time and higher image quality with similar diagnostic confidence compared with standard TSE MRI in the shoulder. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Chang and Chow in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Xie Y, Tao H, Li X, et al. Prospective Comparison of Standard and Deep Learning-reconstructed Turbo Spin-Echo MRI of the Shoulder. Radiology. 2024. PMID: 38193842. doi:10.1148/radiol.231405

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。