髋关节髋臼过渡区软骨损伤的MRI与关节镜表现比较
该回顾性单中心研究纳入136例有症状股骨髋臼撞击征且6个月内行髋关节镜手术者的3T MRI,由3名放射科医生独立评估髋臼软骨唇过渡区形态学损伤或低信号病变,并与关节镜分级对照。MRI形态学病变对关节镜表面化病变敏感度64.9-71.6%、特异度48.4-67.7%,高级别病变更敏感,对波征病变敏感度低(34.5-51.7%);低信号病变诊断价值不确定。
要点
- MRI形态学损伤对髋臼过渡区任何软骨病变敏感度中等,对高级别病变更敏感,对波征病变敏感度低。
- MRI低信号病变的诊断价值不确定,且不同阅片者间一致性差(k=0.097)。
- 形态学病变的阅片者间一致性为中等(k=0.601)。
核心结论
- MRI上过渡区形态学软骨损伤对任何软骨病变敏感度中等,对高级别病变更敏感,对波征病变敏感度低;低信号病变的诊断价值不确定。
研究设计与样本
- 回顾性单中心研究,纳入136例有症状股骨髋臼撞击征且6个月内行髋关节镜手术者的3T MRI髋关节检查,由3名放射科医生独立评估,参考标准为关节镜手术。
关键影像表现/征象
- MRI上过渡区形态学损伤表现为形态学损伤征象,低信号病变表现为低信号病灶。
- 关节镜评估过渡区表面化损伤程度采用改良Outerbridge分级1-4级,并记录非表面化波征的有无。
诊断标准与关键数值
- MRI形态学病变预测关节镜表面化病变的敏感度64.9-71.6%、特异度48.4-67.7%,高级别病变敏感度更高。
- MRI形态学病变预测波征病变的敏感度34.5-51.7%。
- MRI低信号病变预测任何病变的敏感度26.3-62%、特异度43.8-78.0%。
- 形态学病变阅片者间一致性k=0.601(中等),低信号病变k=0.097(差)。
临床应用与阅片要点
- 阅片时应注意MRI形态学损伤对高级别软骨病变更敏感,对波征病变敏感度低。
- MRI低信号病变的诊断价值不确定,阅片者间一致性差。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the performance of morphologic and hypointense signal changes on MRI to predict grades and types of acetabular cartilage damage in the chondrolabral transitional zone (TZ) of the hip identified at arthroscopy.
MATERIALS AND METHODS: This retrospective single-center study reviewed conventional 3T MRI hip studies from individuals with symptomatic femoroacetabular impingement (FAI) and subsequent hip arthroscopy surgery within 6 months. Independent review was made by three radiologists for the presence of morphologic damage or a hypointense signal lesion in the TZ on MRI. Fleiss' kappa statistic was used to assess inter-reader agreement. The degree of TZ surfacing damage (modified Outerbridge grades 1-4) and presence of non-surfacing wave sign at arthroscopic surgery were collected. Relationship between sensitivity and lesion grade was examined.
RESULTS: One hundred thirty-six MRI hip studies from 40 males and 74 females were included (mean age 28.5 years, age range 13-54 years). MRI morphologic lesions had a sensitivity of 64.9-71.6% and specificity of 48.4-67.7% for arthroscopic surfacing lesions, with greater sensitivity seen for higher grade lesions. Low sensitivity was seen for wave sign lesions (34.5-51.7%). MRI hypointense signal lesions had a sensitivity of 26.3-62% and specificity of 43.8-78.0% for any lesion. Inter-reader agreement was moderate for morphologic lesions (k = 0.601) and poor for hypointense signal lesions (k = 0.097).
CONCLUSION: Morphologic cartilage damage in the TZ on MRI had moderate sensitivity for any cartilage lesion, better sensitivity for higher grade lesions, and poor sensitivity for wave sign lesions. The diagnostic value of hypointense signal lesions was uncertain.
引用
- Markhardt BK, Hund S, Rosas HG, et al. Comparison of MRI and arthroscopy findings for transitional zone cartilage damage in the acetabulum of the hip joint. Skeletal Radiol. 2024. PMID: 38225402. doi:10.1007/s00256-024-04563-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。