文献速递乳腺MR

将Kaiser评分作为乳腺病变分类的临床决策规则:计算机辅助曲线类型分析能否改善诊断?

Using the Kaiser Score as a clinical decision rule for breast lesion classification: Does computer-assisted curve type analysis improve diagnosis?
PubMed 文献 · Eur J Radiol · 2023-12-19

本研究回顾性分析2013至2015年间按EUSOBI推荐行1.5T乳腺MRI后活检的连续BI-RADS 0、4或5患者共220个病变,比较视觉与自动像素编码参数图评估时间-信号强度曲线类型对Kaiser评分诊断效能的影响。结果显示视觉与参数图两种读片方式间Kaiser评分鉴别良恶性病变的效能无显著差异(P=0.119;视觉AUC 0.875、敏感度95%、特异度63%;参数图AUC 0.901、敏感度97%、特异度65%),分别分析肿块与非肿块病变亦无差异(P=0.130和P=0.787)。

要点

  • Kaiser评分鉴别乳腺良恶性病变的效能不受曲线类型评估方法(视觉或参数图)影响(P=0.119)。
  • 视觉读片AUC 0.875、敏感度95%、特异度63%;参数图AUC 0.901、敏感度97%、特异度65%。
  • 肿块与非肿块病变分别分析,参数图与视觉曲线类型Kaiser评分亦无差异(P=0.130和P=0.787)。

核心结论

  • Kaiser评分的诊断效能很大程度上独立于曲线类型评估方法,证实其作为乳腺MRI临床决策规则在各类乳腺病变临床常规中的稳健性。

研究设计与样本

  • 经IRB批准的回顾性研究,分析2013至2015年间按EUSOBI推荐行1.5T乳腺MRI后活检的连续BI-RADS 0、4或5患者,共220个病变(良性147个、恶性73个),包括肿块148个和非肿块病变72个;Kaiser评分含五个标准(毛刺状、信号强度-时间曲线类型、病变边缘、内部强化、水肿),评分范围1(最低)至11(乳腺癌最高风险);曲线类型(持续型、平台型或流出型)由两名放射科医师独立视觉评估及使用像素级彩色编码曲线类型参数图评估;两种读片方式间Kaiser评分诊断效能差异采用ROC分析比较。

诊断标准与关键数值

  • Kaiser评分为含五个标准(毛刺状、信号强度-时间曲线类型、病变边缘、内部强化、水肿)的临床决策规则,评分范围1至11分;视觉曲线类型分析Kaiser评分鉴别良恶性:AUC 0.875、敏感度95%、特异度63%;参数图曲线类型分析:AUC 0.901、敏感度97%、特异度65%;两者比较P=0.119;肿块病变两种方法比较P=0.130,非肿块病变比较P=0.787。

临床应用与阅片要点

  • Kaiser评分作为乳腺MRI临床决策规则,其诊断效能不受曲线类型评估方法(视觉或像素级参数图)影响,可用于临床常规中各类乳腺病变。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to investigate the effect of using visual or automatic enhancement curve type assessment on the diagnostic performance of the Kaiser Score (KS), a clinical decision rule for breast MRI.

METHOD: This IRB-approved retrospective study analyzed consecutive conventional BI-RADS 0, 4 or 5 patients who underwent biopsy after 1.5T breast MRI according to EUSOBI recommendations between 2013 and 2015. The KS includes five criteria (spiculations; signal intensity (SI)-time curve type; margins of the lesion; internal enhancement; and presence of edema) resulting in scores from 1 (=lowest) to 11 (=highest risk of breast cancer). Enhancement curve types (Persistent, Plateau or Wash-out) were assessed by two radiologists independently visually and using a pixel-wise color-coded computed parametric map of curve types. KS diagnostic performance differences between readings were compared by ROC analysis.

RESULTS: In total 220 lesions (147 benign, 73 malignant) including mass (n = 148) and non-mass lesions (n = 72) were analyzed. KS reading performance in distinguishing benign from malignant lesions did not differ between visual analysis and parametric map (P = 0.119; visual: AUC 0.875, sensitivity 95 %, specificity 63 %; and map: AUC 0.901, sensitivity 97 %, specificity 65 %). Additionally, analyzing mass and non-mass lesions separately, showed no difference between parametric map based and visual curve type-based KS analysis as well (P = 0.130 and P = 0.787).

CONCLUSIONS: The performance of the Kaiser Score is largely independent of the curve type assessment methodology, confirming its robustness as a clinical decision rule for breast MRI in any type of breast lesion in clinical routine.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Pötsch N, Vatteroni G, Clauser P, et al. Using the Kaiser Score as a clinical decision rule for breast lesion classification: Does computer-assisted curve type analysis improve diagnosis? Eur J Radiol. 2023. PMID: 38185026. doi:10.1016/j.ejrad.2023.111271

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。