锥形束乳腺CT与乳腺X线摄影诊断原发性乳腺癌的头对头比较:系统综述与Meta分析
该系统综述与Meta分析比较锥形束乳腺CT(CBBCT)与乳腺X线摄影(MG)诊断原发性乳腺癌的性能,检索截至2023年3月的多个数据库。CBBCT汇总敏感度0.92、特异度0.79、SROC曲线下面积0.93;MG汇总敏感度0.77、特异度0.75、AUC 0.83;CBBCT的汇总敏感度和AUC均显著高于MG(P<0.001)。作者结论认为CBBCT诊断性能优于MG,但两者结果均基于小样本研究,需更大样本和更完善设计的研究进一步验证。
要点
- CBBCT诊断原发性乳腺癌汇总敏感度0.92(95%CI 0.87-0.94),高于MG的0.77(95%CI 0.69-0.83),差异显著(P<0.001)。
- CBBCT汇总特异度0.79(95%CI 0.71-0.85),MG为0.75(95%CI 0.66-0.82)。
- CBBCT的SROC曲线下面积0.93(95%CI 0.90-0.95),显著高于MG的0.83(95%CI 0.80-0.86)(P<0.001)。
核心结论
- CBBCT对原发性乳腺癌的诊断性能优于MG,但CBBCT和MG的结果均基于小样本研究,需更大样本和更完善设计的研究进一步验证。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Embase、Web of Science、中国知网、万方数据和中国科技期刊数据库,检索时间从建库至2023年3月,采用双变量随机效应模型计算敏感度和特异度并构建SROC曲线,使用QUADAS-2清单进行质量评价。
诊断标准与关键数值
- CBBCT诊断原发性乳腺癌的汇总敏感度0.92(95%CI 0.87-0.94),汇总特异度0.79(95%CI 0.71-0.85),SROC曲线下面积0.93(95%CI 0.90-0.95)。
- MG诊断原发性乳腺癌的汇总敏感度0.77(95%CI 0.69-0.83),汇总特异度0.75(95%CI 0.66-0.82),SROC曲线下面积0.83(95%CI 0.80-0.86)。
- Z检验显示CBBCT的汇总敏感度显著高于MG(P<0.001),CBBCT的汇总AUC亦显著高于MG(P<0.001)。
局限性
- CBBCT和MG的结果均基于小样本研究。
- 需要更大样本量和更完善设计的研究来解决该问题。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: To compare the diagnostic performance of cone-beam breast computed tomography (CBBCT) and mammography (MG) in primary breast cancer.
METHODS: PubMed, Embase, Web of Science, China National Knowledge Infrastructure, WanFang DATA, and China Science and Technology Journal databases were searched comprehensively from inception to March 2023. Sensitivity and specificity were calculated using bivariate random-effects models, and a summary receiver operating characteristic (SROC) curve was constructed. Bivariate I2 statistics and meta-regression analyses were also performed. The differences in diagnostic performance between CBBCT and MG were analysed using Z-test statistics. Clinical utility was explored using Fagan's nomogram, and quality assessment was conducted utilising the Quality Assessment of Diagnostic Accuracy Studies-2 checklist.
RESULTS: The summary sensitivity and specificity for CBBCT in diagnosing primary breast cancer were 0.92 (95 % CI: 0.87-0.94) and 0.79 (95 % CI: 0.71-0.85), respectively, and the area under the curve (AUC) of the SROC was 0.93 (95 % CI: 0.90-0.95). For MG, the summary sensitivity and specificity were 0.77 (95 % CI: 0.69-0.83) and 0.75 (95 % CI: 0.66-0.82), respectively, with an AUC of 0.83 (95 % CI: 0.80-0.86). The Z-test revealed that the summary sensitivity of CBBCT was significantly higher than that of MG (P < 0.001). Additionally, the summary AUC of CBBCT was significantly higher than that of MG (P < 0.001).
CONCLUSION: The diagnostic performance of CBBCT for primary breast cancer was better than that of MG. However, the results of both the CBBCT and MG are based on studies with small sample sizes. Further studies with larger sample sizes and more comprehensive designs are required to address this issue.
引用
- Yang L, Zhou Z, Wang J, et al. Head-to-head comparison of cone-beam breast computed tomography and mammography in the diagnosis of primary breast cancer: A systematic review and meta-analysis. Eur J Radiol. 2024. PMID: 38211395. doi:10.1016/j.ejrad.2024.111292