在缺乏动态对比增强的情况下,用于评估超声不确定的卵巢及附件肿块的改良MR评分系统
本研究为横断面回顾性研究,纳入245例患者共340个附件肿块,基于早期增强后系列实性组织强化主观评估联合DWI及ADC图的改良MR评分系统与ADNEX MR评分系统进行对比。改良评分系统敏感度87.3%、特异度94.6%、准确率92.1%;ADNEX MR评分系统敏感度96.6%、特异度91%、准确率92.9%;两者AUC分别为0.909和0.938,差异无统计学意义(P=0.053)。作者认为改良评分系统敏感度较低但特异度较高,准确率无显著差异。
要点
- 改良评分系统敏感度87.3%、特异度94.6%、准确率92.1%。
- ADNEX MR评分系统敏感度96.6%、特异度91%、准确率92.9%。
- 两者AUC分别为0.909和0.938,差异无统计学意义(P=0.053)。
核心结论
- 改良评分系统敏感度低于ADNEX MR评分系统、特异度高于ADNEX MR评分系统,但准确率无显著差异。
研究设计与样本
- 横断面回顾性研究,纳入245例患者共340个附件肿块,基于早期增强后系列实性组织强化主观评估联合DWI及ADC图的改良MR评分系统与ADNEX MR评分系统进行对比。
诊断标准与关键数值
- 改良评分系统敏感度87.3%、特异度94.6%、准确率92.1%。
- ADNEX MR评分系统敏感度96.6%、特异度91%、准确率92.9%。
- 改良评分系统AUC为0.909(95%CI 0.870-0.938),ADNEX MR评分系统AUC为0.938(95%CI 0.907-0.961),两者AUC比较P=0.053。
临床应用与阅片要点
- 作者认为,基于早期增强后系列实性组织强化主观评估联合DWI及ADC图的MR评分系统可能适用于无法进行DCE的影像中心。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Dynamic contrast-enhanced (DCE) MRI is not available in all imaging centres to investigate adnexal masses. We proposed modified magnetic resonance (MR) scoring system based on an assessment of the enhancement of the solid tissue on early phase postcontrast series and diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) map and investigated the validity of this protocols in the current study.
MATERIALS AND METHODS: In this cross-sectional retrospective study, pelvic MRI of a total of 245 patients with 340 adnexal masses were studied based on the proposed modified scoring system and ADNEX MR scoring system.
RESULTS: Modified scoring system with the sensitivity of 87.3% and specificity of 94.6% has an accuracy of 92.1%. Sensitivity, specificity, and accuracy of ADNEX MR scoring system is 96.6%, 91%, and 92.9%, respectively. The area under the receiver operating characteristic curve for the modified scoring system and ADNEX MR scoring system is 0.909 (with 0.870-0.938 95% confidence interval [CI]) and 0.938 (with 0.907-0.961 95% CI), respectively. Pairwise comparison of these area under the curves showed no significant difference (P = .053).
CONCLUSIONS: Modified scoring system is less sensitive than the ADNEX MR scoring system and more specific but the accuracy is not significantly different.
ADVANCES IN KNOWLEDGE: According to our study, MR scoring system based on subjective assessment of the enhancement of the solid tissue on early phase postcontrast series and DWI with ADC map could be applicable in imaging centres that DCE is not available.
引用
- Moradi B, Rahmani M, Aghasi M, et al. Modified MR scoring system for assessment of sonographically indeterminate ovarian and adnexal masses in the absence of dynamic contrast-enhanced. Br J Radiol. 2024. PMID: 38263830. doi:10.1093/bjr/tqad005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。