多参数MRI影像组学提高子宫内膜癌患者术前局部分期的诊断效能
回顾性分析198例子宫内膜癌患者术前多参数MRI,构建影像组学签名联合常规MRI的列线图预测深肌层浸润和宫颈间质浸润;列线图在训练集和测试集检测深肌层浸润的AUC为0.928和0.869,检测宫颈间质浸润的AUC为0.913和0.937,多数优于常规MRI。
要点
- 列线图检测深肌层浸润的AUC在训练集0.928、测试集0.869,均优于常规MRI
- 列线图检测宫颈间质浸润训练集AUC 0.913优于常规MRI,测试集0.937与常规MRI无显著差异
- 常规MRI检测深肌层浸润AUC训练集0.837、测试集0.799;检测宫颈间质浸润训练集0.825、测试集0.858
核心结论
- 将影像组学签名纳入常规MRI的列线图提高了子宫内膜癌术前局部分期的效能。
研究设计与样本
- 回顾性分析198例经组织学确诊的子宫内膜癌患者术前多参数MRI数据,分为训练集138例和测试集60例;从多参数MR图像提取影像组学特征训练和测试深肌层浸润与宫颈间质浸润预测;两名放射科医师在常规MR图像上评估;构建影像组学签名联合常规MR图像的列线图;用ROC曲线下面积(AUC)评估模型性能,并用DeLong检验加Bonferroni校正进行两两比较。
诊断标准与关键数值
- 常规MRI检测深肌层浸润AUC:训练集0.837,测试集0.799
- 常规MRI检测宫颈间质浸润AUC:训练集0.825,测试集0.858
- 列线图检测深肌层浸润AUC:训练集0.928,测试集0.869
- 列线图检测宫颈间质浸润AUC:训练集0.913,测试集0.937
- 列线图在训练集和测试集检测深肌层浸润和宫颈间质浸润的能力优于常规MRI(校正P<0.05),但测试集检测宫颈间质浸润除外(校正P>0.05)
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine whether multiparametric magnetic resonance imaging (MRI) radiomics-based machine learning methods can improve preoperative local staging in patients with endometrial cancer (EC).
METHODS: Data of patients with histologically confirmed EC who underwent preoperative MRI were retrospectively analyzed and divided into a training or test set. Radiomic features extracted from multiparametric MR images were used to train and test the prediction of deep myometrial invasion (DMI) and cervical stromal invasion (CSI). Two radiologists assessed the presence of DMI and CSI on conventional MR images. A combined model incorporating a radiomic signature and conventional MR images was constructed and presented as a nomogram. Performance of the predictive models was assessed using the area under curve (AUC) in the receiver operating curve analysis and pairwise comparison using DeLong's test with Bonferroni correction.
RESULTS: This study included 198 women (training set = 138, test set = 60). Conventional MRI achieved AUCs of 0.837 and 0.799 for detecting DMI and 0.825 and 0.858 for detecting CSI in the training and test sets, respectively. The nomogram achieved AUCs of 0.928 and 0.869 for detecting DMI and 0.913 and 0.937 for detecting CSI in the training and test sets, respectively. The ability of the nomogram to detect DMI and CSI in the two sets was superior to that of conventional MRI (adjusted p < 0.05), except for the ability to detect CSI in the test set (adjusted p > 0.05).
CONCLUSION: A nomogram incorporating radiomics signature into conventional MRI improved the efficacy of preoperative local staging of EC.
引用
- Fang R, Lin N, Weng S, et al. Multiparametric MRI radiomics improves preoperative diagnostic performance for local staging in patients with endometrial cancer. Abdom Radiol (NY). 2024. PMID: 38189937. doi:10.1007/s00261-023-04149-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。