孕妇自觉胎动减少与婴儿体型无关
这项在澳大利亚大型围产中心开展的回顾性研究纳入2016年1月至2020年10月间分娩的45042例非畸形单胎孕妇,其中6690例(14.9%)因胎动减少就诊。分析显示,胎动减少(单次或多次)与婴儿出生体重百分位类别均无关联,胎动减少并不一定需要立即或紧急超声评估胎儿大小。
要点
- 胎动减少就诊者占14.9%,其中80.9%仅就诊一次,19.1%就诊两次及以上。
- 胎动减少与婴儿出生体重百分位类别无关联,无论单次还是多次就诊。
- 胎动减少者与无胎动减少者的总体死产率相似,均为0.1%。
核心结论
- 本研究提示,孕妇因胎动减少就诊与婴儿体型无关;临床医生在决定适当处理时应考虑其他危险因素和整体临床情况;胎动减少不一定需要立即或紧急超声评估胎儿大小。
研究设计与样本
- 澳大利亚布里斯班Mater Mothers医院开展的回顾性研究,纳入2016年1月至2020年10月间分娩的胎龄≥28+0周非畸形单胎婴儿,共45042例孕妇;采用校正多项回归模型评估胎动减少与出生体重百分位的关联,并使用稳健标准误处理患者层面的聚类。
临床应用与阅片要点
- 作者认为,胎动减少不一定需要立即或紧急超声评估胎儿大小;临床医生在决定适当处理时应考虑其他危险因素和整体临床情况。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Fetal movements are often used as a surrogate for fetal wellbeing. Previous research suggests a link between maternal perception of decreased fetal movements (DFM) and small-for-gestational-age (SGA) infants. The aim of this study was to investigate the association between maternal presentation with DFM and birth-weight centile categories at a large Australian perinatal center.
METHODS: This was a retrospective study of non-anomalous singleton infants born at ≥ 28 + 0 weeks' gestation between January 2016 and October 2020 at the Mater Mothers' Hospital in Brisbane, Australia. The primary outcome was the rate of DFM according to birth-weight centile category. Maternal demographic characteristics included age, body mass index, ethnicity, parity, medical conditions and previous stillbirth. The association between DFM and birth-weight centile was evaluated using adjusted multinomial regression models. Robust standard errors were used to account for clustering at the patient level. Wald tests and Akaike's and Bayesian information criteria were used to evaluate models.
RESULTS: Over the 5-year study period, 45 042 women met the inclusion criteria. Of these, 6690 (14.9%) women presented with DFM. Of the DFM cohort, 80.9% (5411/6690) had only one presentation with DFM, and 19.1% (1279/6690) had two or more presentations. The overall stillbirth rate was similar in women with DFM (0.1% (8/6690)) and those without DFM (0.1% (50/38 352)). There was no association between DFM (either single or multiple) and infant birth-weight centile.
CONCLUSIONS: This study suggests that presentation with DFM is not associated with infant size. Clinicians should consider additional risk factors and the overall clinical context when deciding appropriate management. DFM is not necessarily an indication for an immediate or urgent ultrasound scan to assess fetal size. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Stoke R, Crawford K, Jardine L, et al. Maternal perception of decreased fetal movements is independent of infant size. Ultrasound Obstet Gynecol. 2024. PMID: 38237047. doi:10.1002/uog.27587
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。