文献速递妇产影像儿科影像US

开放式与胎儿镜宫内脊柱裂闭合术中的胎儿心血管变化

Fetal cardiovascular changes during open and fetoscopic in-utero spina bifida closure.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-01-01

前瞻性队列研究比较22例开放式与46例胎儿镜宫内脊柱裂闭合术,胎儿镜组心动过缓发生率更高(45.7% vs 18.2%,P=0.03),脐动脉舒张末期血流异常更多(50.0% vs 13.6%,P=0.004),但变化均为暂时性,无急诊分娩或中转开放手术。

要点

  • 胎儿镜组心动过缓发生率45.7%,高于开放组的18.2%(P=0.03)。
  • 胎儿镜组脐动脉舒张末期血流异常发生率50.0%,高于开放组的13.6%(P=0.004)。
  • 胎儿镜组术终胎心率较基线下降-32.4 bpm,开放组为-23.5 bpm(P=0.002)。

核心结论

  • 两种闭合术中均观察到胎心率下降和脐动脉多普勒参数异常,胎儿镜组在hhCO2充气后心动过缓更明显,但停止hhCO2后胎心率恢复,变化均为暂时性。

研究设计与样本

  • 前瞻性队列研究,纳入2019至2023年22例开放式与46例胎儿镜连续宫内闭合术,两组术前咨询和临床管理相似。

关键影像表现/征象

  • 胎儿镜组在手术第2小时胎心率显著低于开放组。
  • 胎儿镜组手术最后阶段胎心率较基线下降-32.4 bpm(95%CI -35.7至-29.1),开放组为-23.5 bpm(95%CI -28.1至-18.8),胎儿镜组下降更明显(P=0.002)。
  • 两组在各评估阶段的脐动脉舒张末期血流或脐动脉搏动指数无差异。

诊断标准与关键数值

  • 胎儿心动过缓定义为胎心率<110 bpm持续10分钟:开放组4/22(18.2%),胎儿镜组21/46(45.7%),P=0.03。
  • 脐动脉舒张末期血流异常定义为舒张末期血流缺失或反向:开放组3/22(13.6%),胎儿镜组23/46(50.0%),P=0.004。

临床应用与阅片要点

  • 术中应系统监测胎心率及脐动脉多普勒参数,留意hhCO2充气后胎儿镜闭合术中的心动过缓。
  • 胎儿镜组观察到的胎心率和脐动脉多普勒变化为暂时性,无病例需急诊分娩,无胎儿镜中转开放。
  • 作者认为这些观察结果应有助于制定宫内脊柱裂闭合术相关围手术期胎儿心动过缓的管理流程。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Fetoscopic closure of spina bifida using heated and humidified carbon dioxide gas (hhCO2) has been associated with lower maternal morbidity compared with open closure. Fetal cardiovascular changes during these surgical interventions are poorly defined. Our objective was to compare fetal bradycardia (defined as fetal heart rate (FHR) < 110 bpm for 10 min) and changes in umbilical artery (UA) Doppler parameters during open vs fetoscopic closure.

METHODS: This was a prospective cohort study of 22 open and 46 fetoscopic consecutive in-utero closures conducted between 2019 and 2023. Both cohorts had similar preoperative counseling and clinical management. FHR and UA Doppler velocimetry were obtained systematically during preoperative assessment, every 5 min during the intraoperative period, and during the postoperative assessment. FHR, UA pulsatility index (PI) and UA end-diastolic flow (EDF) were segmented into hourly periods during surgery, and the lowest values were averaged for analysis. Umbilical vein maximum velocity was measured in the fetoscopic cohort. At each timepoint at which FHR was recorded, maternal heart rate and systolic and diastolic blood pressure were measured.

RESULTS: Fetal bradycardia occurred in 4/22 (18.2%) cases of open closure and 21/46 (45.7%) cases of fetoscopic closure (P = 0.03). FHR decreased gradually in both cohorts after administration of general anesthesia and decreased further during surgery. FHR was significantly lower during hour 2 of surgery in the fetoscopic-repair cohort compared with the open-repair cohort. The change in FHR from baseline in the final stage of fetal surgery was significantly more pronounced in the fetoscopic-repair cohort compared with the open-repair cohort (mean, -32.4 (95% CI, -35.7 to -29.1) bpm vs -23.5 (95% CI, -28.1 to -18.8) bpm; P = 0.002). Abnormal UA-EDF (defined as absent or reversed EDF) occurred in 3/22 (13.6%) cases in the open-repair cohort and 23/46 (50.0%) cases in the fetoscopic-repair cohort (P = 0.004). There were no differences in UA-EDF or UA-PI between closure techniques at the individual stages of assessment.

CONCLUSIONS: We observed a decrease in FHR and abnormalities in UA Doppler parameters during both open and fetoscopic spina bifida closure. Fetal bradycardia was more prominent during fetoscopic closure following hhCO2 insufflation, but FHR recovered after cessation of hhCO2. Changes in FHR and UA Doppler parameters during in-utero spina bifida closure were transient, no cases required emergency delivery and no fetoscopic closure was converted to open closure. These observations should inform algorithms for the perioperative management of fetal bradycardia associated with in-utero spina bifida closure. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Backley S, Bergh EP, Garnett J, et al. Fetal cardiovascular changes during open and fetoscopic in-utero spina bifida closure. Ultrasound Obstet Gynecol. 2024. PMID: 38207160. doi:10.1002/uog.27579

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。